Pure phase encode magnetic field gradient monitor.

Hui Han1, Rodney P MacGregor, Bruce J Balcom.   

Abstract

Numerous methods have been developed to measure MRI gradient waveforms and k-space trajectories. The most promising new strategy appears to be magnetic field monitoring with RF microprobes. Multiple RF microprobes may record the magnetic field evolution associated with a wide variety of imaging pulse sequences. The method involves exciting one or more test samples and measuring the time evolution of magnetization through the FIDs. Two critical problems remain. The gradient waveform duration is limited by the sample T(2)*, while the k-space maxima are limited by gradient dephasing. The method presented is based on pure phase encode FIDs and solves the above two problems in addition to permitting high strength gradient measurement. A small doped water phantom (1-3 mm droplet, T(1), T(2), T(2)* < 100 micros) within a microprobe is excited by a series of closely spaced broadband RF pulses each followed by FID single point acquisition. Two trial gradient waveforms have been chosen to illustrate the technique, neither of which could be measured by the conventional RF microprobe measurement. The first is an extended duration gradient waveform while the other illustrates the new method's ability to measure gradient waveforms with large net area and/or high amplitude. The new method is a point monitor with simple implementation and low cost hardware requirements.

Entities:  

Mesh:

Year:  2009        PMID: 19815435     DOI: 10.1016/j.jmr.2009.09.011

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  4 in total

1.  Rapid single scan ramped hybrid-encoding for bicomponent T2* mapping in a human knee joint: A feasibility study.

Authors:  Hyungseok Jang; Alan B McMillan; Yajun Ma; Saeed Jerban; Eric Y Chang; Jiang Du; Richard Kijowski
Journal:  NMR Biomed       Date:  2020-08-05       Impact factor: 4.044

2.  Quantification and compensation of eddy-current-induced magnetic-field gradients.

Authors:  William M Spees; Niels Buhl; Peng Sun; Joseph J H Ackerman; Jeffrey J Neil; Joel R Garbow
Journal:  J Magn Reson       Date:  2011-06-25       Impact factor: 2.229

3.  A rapid and robust gradient measurement technique using dynamic single-point imaging.

Authors:  Hyungseok Jang; Alan B McMillan
Journal:  Magn Reson Med       Date:  2016-10-03       Impact factor: 4.668

4.  Accurate Measurement of Magnetic Resonance Imaging Gradient Characteristics.

Authors:  Hui Liu; Gerald B Matson
Journal:  Materials (Basel)       Date:  2014       Impact factor: 3.623

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.