Literature DB >> 10861882

Reconstructing MR images from undersampled data: data-weighting considerations.

J G Pipe1.   

Abstract

Data which are sampled more densely than the Nyquist limit in k-space are weighted prior to reconstruction by the inverse of the local sampling density. This work considers the effects of weighting data that are sampled less densely than the Nyquist limit. It specifically analyzes azimuthally undersampled projection reconstruction, variable density spirals, and variable density phase encoding. Effects on resolution, aliasing, and SNR are given. Higher resolution is obtained by weighting undersampled data according to the inverse of sampling density, while better SNR and less aliasing artifact are obtained by weighting undersampled data uniformly. Magn Reson Med 43:867-875, 2000. Copyright 2000 Wiley-Liss, Inc.

Mesh:

Year:  2000        PMID: 10861882     DOI: 10.1002/1522-2594(200006)43:6<867::aid-mrm13>3.0.co;2-2

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  25 in total

1.  Variable-density spiral 3D tailored RF pulses.

Authors:  V Andrew Stenger; Fernando E Boada; Douglas C Noll
Journal:  Magn Reson Med       Date:  2003-11       Impact factor: 4.668

2.  Dynamic magnetic resonance imaging paragraph sign with radial scanning: a post-acquisition paragraph sign keyhole approach.

Authors:  R Lethmate; H Ratiney; F T A W Wajer; Y Crémillieux; D van Ormondt; D Graveron-Demilly
Journal:  MAGMA       Date:  2003-02       Impact factor: 2.310

3.  Processing of ND NMR spectra sampled in polar coordinates: a simple Fourier transform instead of a reconstruction.

Authors:  Dominique Marion
Journal:  J Biomol NMR       Date:  2006-09-09       Impact factor: 2.835

4.  Using adiabatic inversion pulses for long-T2 suppression in ultrashort echo time (UTE) imaging.

Authors:  Peder E Z Larson; Steven M Conolly; John M Pauly; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2007-11       Impact factor: 4.668

5.  Ultrashort echo time MRI of pulmonary water content: assessment in a sponge phantom at 1.5 and 3.0 Tesla.

Authors:  Francesco Molinari; Ananth J Madhuranthakam; Robert Lenkinski; Alexander A Bankier
Journal:  Diagn Interv Radiol       Date:  2014 Jan-Feb       Impact factor: 2.630

6.  Least-square NUFFT methods applied to 2-D and 3-D radially encoded MR image reconstruction.

Authors:  Jiayu Song; Yanhui Liu; Sally L Gewalt; Gary Cofer; G Allan Johnson; Qing Huo Liu
Journal:  IEEE Trans Biomed Eng       Date:  2009-01-23       Impact factor: 4.538

7.  Ramped hybrid encoding for improved ultrashort echo time imaging.

Authors:  Hyungseok Jang; Curtis N Wiens; Alan B McMillan
Journal:  Magn Reson Med       Date:  2015-09-18       Impact factor: 4.668

8.  A rapid and robust gradient measurement technique using dynamic single-point imaging.

Authors:  Hyungseok Jang; Alan B McMillan
Journal:  Magn Reson Med       Date:  2016-10-03       Impact factor: 4.668

9.  Accelerated 4D quantitative single point EPR imaging using model-based reconstruction.

Authors:  Hyungseok Jang; Shingo Matsumoto; Nallathamby Devasahayam; Sankaran Subramanian; Jiachen Zhuo; Murali C Krishna; Alan B McMillan
Journal:  Magn Reson Med       Date:  2014-05-06       Impact factor: 4.668

10.  Three-dimensional imaging of ventilation dynamics in asthmatics using multiecho projection acquisition with constrained reconstruction.

Authors:  James H Holmes; Rafael L O'Halloran; Ethan K Brodsky; Thorsten A Bley; Christopher J Francois; Julia V Velikina; Ronald L Sorkness; William W Busse; Sean B Fain
Journal:  Magn Reson Med       Date:  2009-12       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.