Curtis N Wiens1, Nathan S Artz1,2, Hyungseok Jang1,3, Alan B McMillan1, Scott B Reeder1,4,5,6,7. 1. Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA. 2. Department of Diagnostic Imaging, St. Jude Children's St. Jude Children's Research Hospital, Memphis, Tennessee, USA. 3. Department of Electrical and Computer Engineering, University of Wisconsin, Madison, Wisconsin, USA. 4. Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA. 5. Department of Biomedical Engineering, University of Wisconsin, Madison, Wisconsin, USA. 6. Department of Medicine, University of Wisconsin, Madison, Wisconsin, USA. 7. Dept. of Emergency Medicine, University of Wisconsin, Madison, Wisconsin, USA.
Abstract
PURPOSE: To develop an externally calibrated parallel imaging technique for three-dimensional multispectral imaging (3D-MSI) in the presence of metallic implants. THEORY AND METHODS: A fast, ultrashort echo time (UTE) calibration acquisition is proposed to enable externally calibrated parallel imaging techniques near metallic implants. The proposed calibration acquisition uses a broadband radiofrequency (RF) pulse to excite the off-resonance induced by the metallic implant, fully phase-encoded imaging to prevent in-plane distortions, and UTE to capture rapidly decaying signal. The performance of the externally calibrated parallel imaging reconstructions was assessed using phantoms and in vivo examples. RESULTS: Phantom and in vivo comparisons to self-calibrated parallel imaging acquisitions show that significant reductions in acquisition times can be achieved using externally calibrated parallel imaging with comparable image quality. Acquisition time reductions are particularly large for fully phase-encoded methods such as spectrally resolved fully phase-encoded three-dimensional (3D) fast spin-echo (SR-FPE), in which scan time reductions of up to 8 min were obtained. CONCLUSION: A fully phase-encoded acquisition with broadband excitation and UTE enabled externally calibrated parallel imaging for 3D-MSI, eliminating the need for repeated calibration regions at each frequency offset. Significant reductions in acquisition time can be achieved, particularly for fully phase-encoded methods like SR-FPE. Magn Reson Med 77:2303-2309, 2017.
PURPOSE: To develop an externally calibrated parallel imaging technique for three-dimensional multispectral imaging (3D-MSI) in the presence of metallic implants. THEORY AND METHODS: A fast, ultrashort echo time (UTE) calibration acquisition is proposed to enable externally calibrated parallel imaging techniques near metallic implants. The proposed calibration acquisition uses a broadband radiofrequency (RF) pulse to excite the off-resonance induced by the metallic implant, fully phase-encoded imaging to prevent in-plane distortions, and UTE to capture rapidly decaying signal. The performance of the externally calibrated parallel imaging reconstructions was assessed using phantoms and in vivo examples. RESULTS: Phantom and in vivo comparisons to self-calibrated parallel imaging acquisitions show that significant reductions in acquisition times can be achieved using externally calibrated parallel imaging with comparable image quality. Acquisition time reductions are particularly large for fully phase-encoded methods such as spectrally resolved fully phase-encoded three-dimensional (3D) fast spin-echo (SR-FPE), in which scan time reductions of up to 8 min were obtained. CONCLUSION: A fully phase-encoded acquisition with broadband excitation and UTE enabled externally calibrated parallel imaging for 3D-MSI, eliminating the need for repeated calibration regions at each frequency offset. Significant reductions in acquisition time can be achieved, particularly for fully phase-encoded methods like SR-FPE. Magn Reson Med 77:2303-2309, 2017.
Authors: L M White; J K Kim; M Mehta; N Merchant; M E Schweitzer; W B Morrison; C R Hutchison; A E Gross Journal: Radiology Date: 2000-04 Impact factor: 11.105
Authors: Charles A McKenzie; Ernest N Yeh; Michael A Ohliger; Mark D Price; Daniel K Sodickson Journal: Magn Reson Med Date: 2002-03 Impact factor: 4.668
Authors: Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase Journal: Magn Reson Med Date: 2002-06 Impact factor: 4.668
Authors: K M Koch; A C Brau; W Chen; G E Gold; B A Hargreaves; M Koff; G C McKinnon; H G Potter; K F King Journal: Magn Reson Med Date: 2011-01 Impact factor: 4.668
Authors: Steven Kurtz; Fionna Mowat; Kevin Ong; Nathan Chan; Edmund Lau; Michael Halpern Journal: J Bone Joint Surg Am Date: 2005-07 Impact factor: 5.284
Authors: Hyungseok Jang; Alan B McMillan; Yajun Ma; Saeed Jerban; Eric Y Chang; Jiang Du; Richard Kijowski Journal: NMR Biomed Date: 2020-08-05 Impact factor: 4.044
Authors: Curtis N Wiens; Nathan S Artz; Hyungseok Jang; Alan B McMillan; Kevin M Koch; Scott B Reeder Journal: Magn Reson Med Date: 2017-08-21 Impact factor: 4.668
Authors: Zoe Doyle; Daehyun Yoon; Philip K Lee; Jarrett Rosenberg; Brian A Hargreaves; Christopher F Beaulieu; Kathryn J Stevens Journal: Skeletal Radiol Date: 2021-07-05 Impact factor: 2.199