Literature DB >> 28686800

Accelerated three-dimensional multispectral MRI with robust principal component analysis for separation of on- and off-resonance signals.

Evan Levine1, Kathryn Stevens1, Christopher Beaulieu1, Brian Hargreaves1.   

Abstract

PURPOSE: To enable highly accelerated distortion-free MRI near metal by separating on- and off-resonance to exploit the redundancy of slice-phase encoding for the dominant on-resonance component.
METHODS: Multispectral MRI techniques resolve off-resonance distortions by a combination of limited excitation bins and additional encoding. Inspired by robust principal component analysis, a novel compact representation of multispectral images as a sum of rank-one and sparse matrices corresponding to on- and off-resonance respectively is described. This representation is used in a calibration-free and model-free reconstruction for data with an undersampling pattern that varies between bins. Retrospective undersampling was used to compare the proposed reconstruction and bin-by-bin compressed sensing. Hip images were acquired in eight patients with standard and prospectively undersampled three-dimensional multispectral imaging, and image quality was evaluated by two radiologists on a 5-point scale.
RESULTS: Experiments with retrospective undersampling showed that the enhanced sparsity afforded by the separation greatly reduces reconstruction errors and artifacts. Images from prospectively undersampled multispectral imaging offered 2.6-3.4-fold (18-24-fold overall) acceleration compared to standard multispectral imaging with parallel imaging and partial-Fourier acceleration with equivalence in all qualitative assessments within a tolerance of one point (P < 0.004).
CONCLUSION: Three-dimensional multispectral imaging can be highly accelerated by varying undersampling between bins and separating on- and off-resonance. Magn Reson Med 79:1495-1505, 2018.
© 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  compressed sensing; low rank; metal artifacts; metallic implants

Mesh:

Year:  2017        PMID: 28686800      PMCID: PMC5756705          DOI: 10.1002/mrm.26819

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  17 in total

1.  Imaging near metal with a MAVRIC-SEMAC hybrid.

Authors:  K M Koch; A C Brau; W Chen; G E Gold; B A Hargreaves; M Koff; G C McKinnon; H G Potter; K F King
Journal:  Magn Reson Med       Date:  2011-01       Impact factor: 4.668

2.  Virtual coil concept for improved parallel MRI employing conjugate symmetric signals.

Authors:  Martin Blaimer; Marcel Gutberlet; Peter Kellman; Felix A Breuer; Herbert Köstler; Mark A Griswold
Journal:  Magn Reson Med       Date:  2009-01       Impact factor: 4.668

3.  A multispectral three-dimensional acquisition technique for imaging near metal implants.

Authors:  Kevin M Koch; John E Lorbiecki; R Scott Hinks; Kevin F King
Journal:  Magn Reson Med       Date:  2009-02       Impact factor: 4.668

4.  Total inhomogeneity correction including chemical shifts and susceptibility by view angle tilting.

Authors:  Z H Cho; D J Kim; Y K Kim
Journal:  Med Phys       Date:  1988 Jan-Feb       Impact factor: 4.071

5.  Highly accelerated dynamic contrast enhanced imaging.

Authors:  Robert Marc Lebel; Jesse Jones; Jean-Christophe Ferre; Meng Law; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

6.  Dynamic MR image reconstruction-separation from undersampled (k,t)-space via low-rank plus sparse prior.

Authors:  Benjamin Trémoulhéac; Nikolaos Dikaios; David Atkinson; Simon R Arridge
Journal:  IEEE Trans Med Imaging       Date:  2014-04-30       Impact factor: 10.048

7.  Accelerating sequences in the presence of metal by exploiting the spatial distribution of off-resonance.

Authors:  Matthew R Smith; Nathan S Artz; Kevin M Koch; Alexey Samsonov; Scott B Reeder
Journal:  Magn Reson Med       Date:  2014-01-15       Impact factor: 4.668

8.  Sparse-SEMAC: rapid and improved SEMAC metal implant imaging using SPARSE-SENSE acceleration.

Authors:  Ricardo Otazo; Mathias Nittka; Mary Bruno; Esther Raithel; Christian Geppert; Soterios Gyftopoulos; Michael Recht; Leon Rybak
Journal:  Magn Reson Med       Date:  2016-07-25       Impact factor: 4.668

9.  SEMAC: Slice Encoding for Metal Artifact Correction in MRI.

Authors:  Wenmiao Lu; Kim Butts Pauly; Garry E Gold; John M Pauly; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2009-07       Impact factor: 4.668

10.  Compressed Sensing SEMAC: 8-fold Accelerated High Resolution Metal Artifact Reduction MRI of Cobalt-Chromium Knee Arthroplasty Implants.

Authors:  Jan Fritz; Shivani Ahlawat; Shadpour Demehri; Gaurav K Thawait; Esther Raithel; Wesley D Gilson; Mathias Nittka
Journal:  Invest Radiol       Date:  2016-10       Impact factor: 6.016

View more
  3 in total

1.  Motion-robust reconstruction of multishot diffusion-weighted images without phase estimation through locally low-rank regularization.

Authors:  Yuxin Hu; Evan G Levine; Qiyuan Tian; Catherine J Moran; Xiaole Wang; Valentina Taviani; Shreyas S Vasanawala; Jennifer A McNab; Bruce A Daniel; Brian L Hargreaves
Journal:  Magn Reson Med       Date:  2018-10-22       Impact factor: 4.668

2.  Accelerating the 3D T mapping of cartilage using a signal-compensated robust tensor principal component analysis model.

Authors:  Yuanyuan Liu; Leslie Ying; Weitian Chen; Zhuo-Xu Cui; Qingyong Zhu; Xin Liu; Hairong Zheng; Dong Liang; Yanjie Zhu
Journal:  Quant Imaging Med Surg       Date:  2021-08

3.  Clinical utility of accelerated MAVRIC-SL with robust-PCA compared to conventional MAVRIC-SL in evaluation of total hip arthroplasties.

Authors:  Zoe Doyle; Daehyun Yoon; Philip K Lee; Jarrett Rosenberg; Brian A Hargreaves; Christopher F Beaulieu; Kathryn J Stevens
Journal:  Skeletal Radiol       Date:  2021-07-05       Impact factor: 2.199

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.