Literature DB >> 20981709

Imaging near metal with a MAVRIC-SEMAC hybrid.

K M Koch1, A C Brau, W Chen, G E Gold, B A Hargreaves, M Koff, G C McKinnon, H G Potter, K F King.   

Abstract

The recently developed multi-acquisition with variable resonance image combination (MAVRIC) and slice-encoding metal artifact correction (SEMAC) techniques can significantly reduce image artifacts commonly encountered near embedded metal hardware. These artifact reductions are enabled by applying alternative spectral and spatial-encoding schemes to conventional spin-echo imaging techniques. Here, the MAVRIC and SEMAC concepts are connected and discussed. The development of a hybrid technique that utilizes strengths of both methods is then introduced. The presented technique is shown capable of producing minimal artifact, high-resolution images near total joint replacements in a clinical setting.
© 2010 Wiley-Liss, Inc.

Mesh:

Substances:

Year:  2011        PMID: 20981709     DOI: 10.1002/mrm.22523

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  70 in total

1.  Modeling of active shimming of metallic needles for interventional MRI.

Authors:  Saikat Sengupta
Journal:  Magn Reson Med       Date:  2020-06-29       Impact factor: 4.668

2.  Review. The Agfa Mayneord lecture: MRI of short and ultrashort T₂ and T₂* components of tissues, fluids and materials using clinical systems.

Authors:  G M Bydder
Journal:  Br J Radiol       Date:  2011-12       Impact factor: 3.039

Review 3.  An illustrative review to understand and manage metal-induced artifacts in musculoskeletal MRI: a primer and updates.

Authors:  J P Dillenseger; S Molière; P Choquet; C Goetz; M Ehlinger; G Bierry
Journal:  Skeletal Radiol       Date:  2016-02-02       Impact factor: 2.199

4.  Improved field-mapping and artifact correction in multispectral imaging.

Authors:  Brady Quist; Xinwei Shi; Hans Weber; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2017-03-05       Impact factor: 4.668

5.  Reducing metallic artefacts in post-operative spinal imaging: slice encoding for metal artefact correction with dual-source parallel radiofrequency excitation MRI at 3.0 T.

Authors:  K D Song; Y C Yoon; J Park
Journal:  Br J Radiol       Date:  2013-07       Impact factor: 3.039

6.  MRI monitoring of focused ultrasound sonications near metallic hardware.

Authors:  Hans Weber; Pejman Ghanouni; Aurea Pascal-Tenorio; Kim Butts Pauly; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2017-12-07       Impact factor: 4.668

7.  Metal artifact reduction MRI of total ankle arthroplasty implants.

Authors:  Cesar de Cesar Netto; Lucas F Fonseca; Benjamin Fritz; Steven E Stern; Esther Raithel; Mathias Nittka; Lew C Schon; Jan Fritz
Journal:  Eur Radiol       Date:  2017-12-07       Impact factor: 5.315

Review 8.  MRI-only treatment planning: benefits and challenges.

Authors:  Amir M Owrangi; Peter B Greer; Carri K Glide-Hurst
Journal:  Phys Med Biol       Date:  2018-02-26       Impact factor: 3.609

9.  Accelerating sequences in the presence of metal by exploiting the spatial distribution of off-resonance.

Authors:  Matthew R Smith; Nathan S Artz; Kevin M Koch; Alexey Samsonov; Scott B Reeder
Journal:  Magn Reson Med       Date:  2014-01-15       Impact factor: 4.668

10.  Characterizing the limits of MRI near metallic prostheses.

Authors:  Matthew R Smith; Nathan S Artz; Curtis Wiens; Diego Hernando; Scott B Reeder
Journal:  Magn Reson Med       Date:  2014-12-05       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.