Literature DB >> 11870840

Self-calibrating parallel imaging with automatic coil sensitivity extraction.

Charles A McKenzie1, Ernest N Yeh, Michael A Ohliger, Mark D Price, Daniel K Sodickson.   

Abstract

Calibration of the spatial sensitivity functions of coil arrays is a crucial element in parallel magnetic resonance imaging (PMRI). The most common approach has been to measure coil sensitivities directly using one or more low-resolution images acquired before or after accelerated data acquisition. However, since it is difficult to ensure that the patient and coil array will be in exactly the same positions during both calibration scans and accelerated imaging, this approach can introduce sensitivity miscalibration errors into PMRI reconstructions. This work shows that it is possible to extract sensitivity calibration images directly from a fully sampled central region of a variable-density k-space acquisition. These images have all the features of traditional PMRI sensitivity calibrations and therefore may be used for any PMRI reconstruction technique without modification. Because these calibration data are acquired simultaneously with the data to be reconstructed, errors due to sensitivity miscalibration are eliminated. In vivo implementations of self-calibrating parallel imaging using a flexible coil array are demonstrated in abdominal imaging and in real-time cardiac imaging studies. Copyright 2002 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2002        PMID: 11870840     DOI: 10.1002/mrm.10087

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  49 in total

Review 1.  MR spectroscopy and spectroscopic imaging of the brain.

Authors:  He Zhu; Peter B Barker
Journal:  Methods Mol Biol       Date:  2011

2.  Real-time accelerated interactive MRI with adaptive TSENSE and UNFOLD.

Authors:  Michael A Guttman; Peter Kellman; Alexander J Dick; Robert J Lederman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2003-08       Impact factor: 4.668

3.  Large field-of-view real-time MRI with a 32-channel system.

Authors:  Christopher J Hardy; Robert D Darrow; Manojkumar Saranathan; Randy O Giaquinto; Yudong Zhu; Charles L Dumoulin; Paul A Bottomley
Journal:  Magn Reson Med       Date:  2004-10       Impact factor: 4.668

4.  MODEL-BASED IMAGE RECONSTRUCTION FOR MRI.

Authors:  Jeffrey A Fessler
Journal:  IEEE Signal Process Mag       Date:  2010-07-01       Impact factor: 12.551

5.  Image reconstruction in SNR units: a general method for SNR measurement.

Authors:  Peter Kellman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2005-12       Impact factor: 4.668

6.  High-resolution steady-state free precession coronary magnetic resonance angiography within a breath-hold: parallel imaging with extended cardiac data acquisition.

Authors:  Jaeseok Park; Andrew C Larson; Qiang Zhang; Orlando Simonetti; Debiao Li
Journal:  Magn Reson Med       Date:  2005-11       Impact factor: 4.668

Review 7.  Real-time, Interactive MRI for cardiovascular interventions.

Authors:  Elliot R McVeigh; Michael A Guttman; Peter Kellman; Amish N Raval; Robert J Lederman
Journal:  Acad Radiol       Date:  2005-09       Impact factor: 3.173

8.  Volumetric late gadolinium-enhanced myocardial imaging with retrospective inversion time selection.

Authors:  Steve Kecskemeti; Kevin Johnson; Christopher J François; Mark L Schiebler; Orhan Unal
Journal:  J Magn Reson Imaging       Date:  2013-02-06       Impact factor: 4.813

9.  Accelerated whole-heart coronary MRA using motion-corrected sensitivity encoding with three-dimensional projection reconstruction.

Authors:  Jianing Pang; Behzad Sharif; Reza Arsanjani; Xiaoming Bi; Zhaoyang Fan; Qi Yang; Kuncheng Li; Daniel S Berman; Debiao Li
Journal:  Magn Reson Med       Date:  2014-01-16       Impact factor: 4.668

10.  Diagnostic performance of 64-MDCT and 1.5-T MRI with high-resolution sequences in the T staging of gastric cancer: a comparative analysis with histopathology.

Authors:  M Anzidei; A Napoli; F Zaccagna; P Di Paolo; C Zini; B Cavallo Marincola; D Geiger; C Catalano; R Passariello
Journal:  Radiol Med       Date:  2009-09-22       Impact factor: 3.469

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.