Literature DB >> 28833407

Fully phase-encoded MRI near metallic implants using ultrashort echo times and broadband excitation.

Curtis N Wiens1, Nathan S Artz1,2, Hyungseok Jang1, Alan B McMillan1, Kevin M Koch3, Scott B Reeder1,4,5,6,7.   

Abstract

PURPOSE: To develop a fully phase-encoded MRI method for distortion-free imaging near metallic implants, in clinically feasible acquisition times. THEORY AND METHODS: An accelerated 3D fully phase-encoded acquisition with broadband excitation and ultrashort echo times is presented, which uses a broadband radiofrequency pulse to excite the entire off-resonance induced by the metallic implant. Furthermore, fully phase-encoded imaging is used to prevent distortions caused by frequency encoding, and to obtain ultrashort echo times for rapidly decaying signal.
RESULTS: Phantom and in vivo acquisitions were used to describe the relationship among excitation bandwidth, signal loss near metallic implants, and T1 weighting. Shorter radiofrequency pulses captured signal closer to the implant by improving spectral coverage and allowing shorter echo times, whereas longer pulses improved T1 weighting through larger maximum attainable flip angles. Comparisons of fully phase-encoded acquisition with broadband excitation and ultrashort echo times to T1 -weighted multi-acquisition with variable resonance image combination selective were performed in phantoms and subjects with metallic knee and hip prostheses. These acquisitions had similar contrast and acquisition efficiency.
CONCLUSIONS: Accelerated fully phase-encoded acquisitions with ultrashort echo times and broadband excitation can generate distortion free images near metallic implants in clinically feasible acquisition times. Magn Reson Med 79:2156-2163, 2018.
© 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  fully phase encoded; metallic implant; single point imaging; ultrashort TE

Mesh:

Substances:

Year:  2017        PMID: 28833407      PMCID: PMC5811328          DOI: 10.1002/mrm.26859

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  31 in total

1.  Imaging near metal with a MAVRIC-SEMAC hybrid.

Authors:  K M Koch; A C Brau; W Chen; G E Gold; B A Hargreaves; M Koff; G C McKinnon; H G Potter; K F King
Journal:  Magn Reson Med       Date:  2011-01       Impact factor: 4.668

2.  MRI of hip prostheses using single-point methods: in vitro studies towards the artifact-free imaging of individuals with metal implants.

Authors:  P Ramos-Cabrer; J P M van Duynhoven; A Van der Toorn; K Nicolay
Journal:  Magn Reson Imaging       Date:  2004-10       Impact factor: 2.546

3.  RF artifacts caused by metallic implants or instruments which get more prominent at 3 T: an in vitro study.

Authors:  Hansjörg Graf; Ulrike A Lauer; Alexander Berger; Fritz Schick
Journal:  Magn Reson Imaging       Date:  2005-04       Impact factor: 2.546

4.  Mapping B(1)-induced eddy current effects near metallic structures in MR images: a comparison of simulation and experiment.

Authors:  S Vashaee; F Goora; M M Britton; B Newling; B J Balcom
Journal:  J Magn Reson       Date:  2014-11-08       Impact factor: 2.229

5.  Polarized multichannel transmit MRI to reduce shading near metal implants.

Authors:  Theresa J Bachschmidt; Michael Köhler; Jürgen Nistler; Christian Geppert; Peter M Jakob; Mathias Nittka
Journal:  Magn Reson Med       Date:  2015-02-13       Impact factor: 4.668

6.  Prevalence of primary and revision total hip and knee arthroplasty in the United States from 1990 through 2002.

Authors:  Steven Kurtz; Fionna Mowat; Kevin Ong; Nathan Chan; Edmund Lau; Michael Halpern
Journal:  J Bone Joint Surg Am       Date:  2005-07       Impact factor: 5.284

7.  Accelerating sequences in the presence of metal by exploiting the spatial distribution of off-resonance.

Authors:  Matthew R Smith; Nathan S Artz; Kevin M Koch; Alexey Samsonov; Scott B Reeder
Journal:  Magn Reson Med       Date:  2014-01-15       Impact factor: 4.668

8.  Characterizing the limits of MRI near metallic prostheses.

Authors:  Matthew R Smith; Nathan S Artz; Curtis Wiens; Diego Hernando; Scott B Reeder
Journal:  Magn Reson Med       Date:  2014-12-05       Impact factor: 4.668

9.  Dual inversion recovery, ultrashort echo time (DIR UTE) imaging: creating high contrast for short-T(2) species.

Authors:  Jiang Du; Atsushi M Takahashi; Won C Bae; Christine B Chung; Graeme M Bydder
Journal:  Magn Reson Med       Date:  2010-02       Impact factor: 4.668

10.  SEMAC: Slice Encoding for Metal Artifact Correction in MRI.

Authors:  Wenmiao Lu; Kim Butts Pauly; Garry E Gold; John M Pauly; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2009-07       Impact factor: 4.668

View more
  6 in total

Review 1.  Magnetic Resonance Imaging of Hard Tissues and Hard Tissue Engineered Bio-substitutes.

Authors:  Simone Mastrogiacomo; Weiqiang Dou; John A Jansen; X Frank Walboomers
Journal:  Mol Imaging Biol       Date:  2019-12       Impact factor: 3.488

2.  Rapid single scan ramped hybrid-encoding for bicomponent T2* mapping in a human knee joint: A feasibility study.

Authors:  Hyungseok Jang; Alan B McMillan; Yajun Ma; Saeed Jerban; Eric Y Chang; Jiang Du; Richard Kijowski
Journal:  NMR Biomed       Date:  2020-08-05       Impact factor: 4.044

3.  True phase quantitative susceptibility mapping using continuous single-point imaging: a feasibility study.

Authors:  Hyungseok Jang; Xing Lu; Michael Carl; Adam C Searleman; Saeed Jerban; Yajun Ma; Annette von Drygalski; Eric Y Chang; Jiang Du
Journal:  Magn Reson Med       Date:  2018-10-16       Impact factor: 4.668

4.  Volumetric and multispectral DWI near metallic implants using a non-linear phase Carr-Purcell-Meiboom-Gill diffusion preparation.

Authors:  Philip K Lee; Daehyun Yoon; Jesse K Sandberg; Shreyas S Vasanawala; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2022-01-11       Impact factor: 4.668

5.  Magnetic Resonance Guided Navigation of Untethered Microgrippers.

Authors:  Arijit Ghosh; Yizhang Liu; Dmitri Artemov; David H Gracias
Journal:  Adv Healthc Mater       Date:  2020-07-21       Impact factor: 9.933

6.  High-resolution, non-contrast-enhanced magnetic resonance angiography of the wrist, hand and digital arteries using optimized implementation of Cartesian quiescent interval slice selective (QISS) at 1.5 T.

Authors:  Mona Salehi Ravesh; Annett Lebenatus; Alexandra Bonietzki; Johannes Hensler; Ioannis Koktzoglou; Robert R Edelman; Joachim Graessner; Olav Jansen; Marcus Both
Journal:  Magn Reson Imaging       Date:  2021-02-11       Impact factor: 2.546

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.