Abstract

PURPOSE: Metal artifact reduction in MRI within clinically feasible scan-times without through-plane aliasing. THEORY AND METHODS: Existing metal artifact reduction techniques include view angle tilting (VAT), which resolves in-plane distortions, and multispectral imaging (MSI) techniques, such as slice encoding for metal artifact correction (SEMAC) and multi-acquisition with variable resonances image combination (MAVRIC), that further reduce image distortions, but significantly increase scan-time. Scan-time depends on anatomy size and anticipated total spectral content of the signal. Signals outside the anticipated spatial region may cause through-plane back-folding. Off-resonance suppression (ORS), using different gradient amplitudes for excitation and refocusing, is proposed to provide well-defined spatial-spectral selectivity in MSI to allow scan-time reduction and flexibility of scan-orientation. Comparisons of MSI techniques with and without ORS were made in phantom and volunteer experiments.
RESULTS: Off-resonance suppressed SEMAC (ORS-SEMAC) and outer-region suppressed MAVRIC (ORS-MAVRIC) required limited through-plane phase encoding steps compared with original MSI. Whereas SEMAC (scan time: 5'46") and MAVRIC (4'12") suffered from through-plane aliasing, ORS-SEMAC and ORS-MAVRIC allowed alias-free imaging in the same scan-times.
CONCLUSION: ORS can be used in MSI to limit the selected spatial-spectral region and contribute to metal artifact reduction in clinically feasible scan-times while avoiding slice aliasing.
© 2014 Wiley Periodicals, Inc.

Entities:  

Keywords:  MAVRIC; SEMAC; arthroplasty; magnetic resonance imaging; metal implants; multispectral imaging

Mesh:

Substances:

Year:  2014        PMID: 24488684     DOI: 10.1002/mrm.25126

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  10 in total

1.  Accelerating fully phase-encoded MRI near metal using multiband radiofrequency excitation.

Authors:  Nathan S Artz; Curtis N Wiens; Matthew R Smith; Diego Hernando; Alexey Samsonov; Scott B Reeder
Journal:  Magn Reson Med       Date:  2016-03-28       Impact factor: 4.668

2.  Clinical evaluation of TOF versus non-TOF on PET artifacts in simultaneous PET/MR: a dual centre experience.

Authors:  Edwin E G W Ter Voert; Patrick Veit-Haibach; Sangtae Ahn; Florian Wiesinger; M Mehdi Khalighi; Craig S Levin; Andrei H Iagaru; Greg Zaharchuk; Martin Huellner; Gaspar Delso
Journal:  Eur J Nucl Med Mol Imaging       Date:  2017-01-26       Impact factor: 9.236

3.  Externally calibrated parallel imaging for 3D multispectral imaging near metallic implants using broadband ultrashort echo time imaging.

Authors:  Curtis N Wiens; Nathan S Artz; Hyungseok Jang; Alan B McMillan; Scott B Reeder
Journal:  Magn Reson Med       Date:  2016-07-12       Impact factor: 4.668

4.  Effects of B1 + Heterogeneity on Spin Echo-Based Liver Iron Estimates.

Authors:  Eamon K Doyle; Samuel Thornton; Nilesh R Ghugre; Thomas D Coates; Krishna S Nayak; John C Wood
Journal:  J Magn Reson Imaging       Date:  2021-09-23       Impact factor: 5.119

5.  In vitro assessment of knee MRI in the presence of metal implants comparing MAVRIC-SL and conventional fast spin echo sequences at 1.5 and 3 T field strength.

Authors:  Hans Liebl; Ursula Heilmeier; Sonia Lee; Lorenzo Nardo; Janina Patsch; Christopher Schuppert; Misung Han; Ina-Christine Rondak; Suchandrima Banerjee; Kevin Koch; Thomas M Link; Roland Krug
Journal:  J Magn Reson Imaging       Date:  2014-06-10       Impact factor: 4.813

Review 6.  Metal artefacts in MRI-guided brachytherapy of cervical cancer.

Authors:  Abraam S Soliman; Amir Owrangi; Ananth Ravi; William Y Song
Journal:  J Contemp Brachytherapy       Date:  2016-08-16

7.  Reliability of slice-encoding for metal artefact correction (SEMAC) MRI to identify prosthesis loosening in patients with painful total hip arthroplasty - a single centre, prospective, surgical validation study.

Authors:  Tsuneari Takahashi; Siddharth Thaker; Giovanni Lettieri; Anthony Redmond; Michael R Backhouse; Martin Stone; Hemant Pandit; Philip O'Connor
Journal:  Br J Radiol       Date:  2022-02-11       Impact factor: 3.629

Review 8.  [Metallic Artifacts on MR Imaging and Methods for Their Reduction].

Authors:  Hye Jung Choo; Sun Joo Lee; Young Han Lee
Journal:  Taehan Yongsang Uihakhoe Chi       Date:  2020-01-31

9.  Dental artifacts in the head and neck region: implications for Dixon-based attenuation correction in PET/MR.

Authors:  Claes N Ladefoged; Adam E Hansen; Sune H Keller; Barbara M Fischer; Jacob H Rasmussen; Ian Law; Andreas Kjær; Liselotte Højgaard; Francois Lauze; Thomas Beyer; Flemming L Andersen
Journal:  EJNMMI Phys       Date:  2015-03-11

10.  Using SEMAC at 3 T MR to evaluate spinal metallic implants and peripheral soft tissue lesions.

Authors:  Chun Xin; Houdong Liu; Shihong Li; Guangwu Lin
Journal:  Medicine (Baltimore)       Date:  2020-06-19       Impact factor: 1.817

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.