Comparison of the measurements of a novel optical biometry: Nidek AL-Scan with Sirius and a ultrasound biometry.

Çağatay Çağlar1, Sücattin İlker Kocamış2, Emre Demir3, Mustafa Durmuş2.   

Abstract

To investigate the accuracy of the measurements of Nidek AL-Scan by comparing with Sirius (CSO, Florence, Italy), a corneal tomography which also employs the Scheimpflug principle, and a commonly used device, ultrasound biometry (UB) (Aviso A/B, Quantel Medical, MT, USA). Right eyes of 85 healthy volunteers (58 women 27 men) with a mean age of 39.24 ± 14.37 years (range 15-68) were enrolled into this comparative prospective study. Average K 2.4, average K 3.3, CCT (central corneal thickness), WTW (white to white distance), ACD (anterior chamber depth) and AL (axial length) were obtained from the AL-Scan and compared with average SimK, CCT, WTW (horizontal anterior chamber diameter) and ACD obtained from Sirius and also compared with ACD and AL obtained from UB. The statistically significant difference was found between all of the measurements (p < 0.001) except the average keratometry values (K2.4, K3.3, SimK) (p = 0.083). There was a perfect correlation between keratometry, CCT and AL measurements of the devices (ICC = 0.977, 0.954, 0.923, respectively) and there was a strong correlation between the WTW measurements of AL-Scan and Sirius (ICC = 0.865). While ACD parameter of AL-Scan and UB showed a perfect correlation (ICC = 0.977), there was a moderate correlation between AL-Scan and Sirius and also between UB and Sirius (ICC = 0.608 and 0.664, respectively). There was a high correlation between the all measurements, besides ACD, of AL-Scan and Sirius and they can be used interchangeably for average keratometry and WTW confidently. However, ACD and CCT have a broader 95 % LoA (-0.039 to 0.744 and -24.985 to 3.691, respectively). In addition, AL-Scan and UB were in good agreement regarding ACD, while differences in AL measurements of UB and AL-Scan were clinically important (95 % LoA = -0.091 to 0.703). Furthermore, UB and Sirius have a moderate agreement regarding ACD (95 % LoA = -0.047 to 0.680).

Entities:  

Keywords:  AL-Scan; Sirius; Ultrasound biometry

Mesh:

Year:  2016        PMID: 27392914     DOI: 10.1007/s10792-016-0284-6

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  19 in total

1.  Differential precision of corneal Pentacam HR measurements in early and advanced keratoconus.

Authors:  Tom H Flynn; Daya P Sharma; Catey Bunce; Mark R Wilkins
Journal:  Br J Ophthalmol       Date:  2015-12-11       Impact factor: 4.638

2.  Sources of error in intraocular lens power calculation.

Authors:  T Olsen
Journal:  J Cataract Refract Surg       Date:  1992-03       Impact factor: 3.351

3.  Comparison of anterior chamber depth measurements taken with the Pentacam, Orbscan IIz and IOLMaster in myopic and emmetropic eyes.

Authors:  Canan Asli Utine; Feyza Altin; Hanefi Cakir; Irfan Perente
Journal:  Acta Ophthalmol       Date:  2008-09-05       Impact factor: 3.761

4.  Comparison of central corneal thickness, thinnest corneal thickness, anterior chamber depth, and simulated keratometry using galilei, Pentacam, and Sirius devices.

Authors:  Mustafa A Anayol; Emre Güler; Ramazan Yağci; Mehmet A Şekeroğlu; Meltem Ylmazoğlu; Hakan Trhş; Ali E Kulak; Pelin Ylmazbaş
Journal:  Cornea       Date:  2014-06       Impact factor: 2.651

5.  Comparison of Anterior Segment-Optical Coherence Tomography Parameters in Phacomorphic Angle Closure and Acute Angle Closure Eyes.

Authors:  Sasan Moghimi; Farshid Ramezani; Mingguang He; Anne L Coleman; Shan C Lin
Journal:  Invest Ophthalmol Vis Sci       Date:  2015-12       Impact factor: 4.799

6.  Evaluation of a new optical biometry device for measurements of ocular components and its comparison with IOLMaster.

Authors:  Jinhai Huang; Giacomo Savini; Jian Li; Weicong Lu; Fan Wu; Jing Wang; Yaolin Li; Yifan Feng; Qinmei Wang
Journal:  Br J Ophthalmol       Date:  2014-05-02       Impact factor: 4.638

7.  Central vault after phakic intraocular lens implantation: correlation with anterior chamber depth, white-to-white distance, spherical equivalent, and patient age.

Authors:  José F Alfonso; Luis Fernández-Vega; Carlos Lisa; Paulo Fernandes; Jorge Jorge; Robert Montés Micó
Journal:  J Cataract Refract Surg       Date:  2012-01       Impact factor: 3.351

8.  Comparison of anterior chamber depth measurements of Nidek AL-Scan and Galilei Dual Scheimpflug Analyzer.

Authors:  Mehmet Serdar Dervişoğulları; Yüksel Totan; Betül Gürağaç
Journal:  Cont Lens Anterior Eye       Date:  2014-11-20       Impact factor: 3.077

9.  Comparison of 2 optical biometers and evaluation of the Camellin-Calossi intraocular lens formula for normal cataractous eyes.

Authors:  Chikako Suto; Emiko Shimamura; Itsumi Watanabe
Journal:  J Cataract Refract Surg       Date:  2015-11       Impact factor: 3.351

10.  Refractive Results Using a New Optical Biometry Device: Comparison With Ultrasound Biometry Data.

Authors:  Serdar Aktas; Hatice Aktas; Mehmet Tetikoglu; Hac Murat Sagdk; Fatih Özcura
Journal:  Medicine (Baltimore)       Date:  2015-12       Impact factor: 1.817

View more
  3 in total

1.  Sirius Scheimpflug-Placido versus ultrasound pachymetry for central corneal thickness: meta-analysis.

Authors:  Yili Jin; Colm McAlinden; Yong Sun; Daizong Wen; Yiran Wang; Jinjin Yu; Ke Feng; Benhao Song; Qinmei Wang; Shihao Chen; Jinhai Huang
Journal:  Eye Vis (Lond)       Date:  2021-02-18

2.  Comparison of central corneal thickness measurements with three different optical devices.

Authors:  Mehmet Barış Üçer; Erdinç Bozkurt
Journal:  Ther Adv Ophthalmol       Date:  2021-02-23

3.  Comparison of anterior segment measurements using Sirius Topographer® and Nidek Axial Length-Scan® with assessing repeatability in patients with cataracts.

Authors:  Resat Duman; Ersan Çetinkaya; Rahmi Duman; Mustafa Dogan; Mehmet Cem Sabaner
Journal:  Indian J Ophthalmol       Date:  2018-03       Impact factor: 1.848

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.