Literature DB >> 24763122

Comparison of central corneal thickness, thinnest corneal thickness, anterior chamber depth, and simulated keratometry using galilei, Pentacam, and Sirius devices.

Mustafa A Anayol1, Emre Güler, Ramazan Yağci, Mehmet A Şekeroğlu, Meltem Ylmazoğlu, Hakan Trhş, Ali E Kulak, Pelin Ylmazbaş.   

Abstract

PURPOSE: The aim was to evaluate the agreement in the central corneal thickness (CCT), thinnest corneal thickness (TCT), anterior chamber depth (ACD), and mean simulated keratometry (simK) measurements using Pentacam, Galilei, and Sirius Scheimpflug systems in normal eyes.
METHODS: Anterior segment measurements were performed with Pentacam, Galilei, and Sirius devices in 32 healthy subjects. The right eye of each participant was selected. Measurements obtained with the 3 systems were compared using repeated-measures analysis of variance and Bonferroni multiple comparisons test.
RESULTS: Analysis of variance determined a significant difference in the anterior segment measurements of CCT, TCT, ACD, and simK between the 3 devices (P < 0.001). Pairwise comparisons of CCT and TCT measurements were significantly different except for the comparison between Pentacam and Sirius. All pairwise comparisons for ACD were statistically significant. The pairwise comparison results for simK values showed that the Galilei and Sirius systems demonstrated better agreement with each other than with Pentacam.
CONCLUSIONS: The results of this study suggest that the Pentacam, Galilei, and Sirius Scheimpflug systems should not be accepted as interchangeable for CCT, TCT, ACD, and simK in healthy subjects.

Entities:  

Mesh:

Year:  2014        PMID: 24763122     DOI: 10.1097/ICO.0000000000000119

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  16 in total

1.  Comparison of the measurements of a novel optical biometry: Nidek AL-Scan with Sirius and a ultrasound biometry.

Authors:  Çağatay Çağlar; Sücattin İlker Kocamış; Emre Demir; Mustafa Durmuş
Journal:  Int Ophthalmol       Date:  2016-07-08       Impact factor: 2.031

2.  Topographic indices and pachymetry in healthy adolescents obtained with Sirius topographer.

Authors:  Emilia Cantera; Magdalena Cortes; Roberto Sacco; Gabriele Vestri; Alessandra Micera
Journal:  Int Ophthalmol       Date:  2017-10-30       Impact factor: 2.031

3.  [Early diagnosis of keratoconus].

Authors:  Stefan J Lang; P Maier; T Böhringer; T Reinhard
Journal:  Ophthalmologe       Date:  2021-07-23       Impact factor: 1.059

4.  Dynamic curvature topography for evaluating the anterior corneal surface change with Corvis ST.

Authors:  Chunhong Ji; Jinhua Yu; Tianjie Li; Lei Tian; Yifei Huang; Yuanyuan Wang; Yongping Zheng
Journal:  Biomed Eng Online       Date:  2015-06-04       Impact factor: 2.819

5.  Evaluation of Central Corneal Thickness Using Corneal Dynamic Scheimpflug Analyzer Corvis ST and Comparison with Pentacam Rotating Scheimpflug System and Ultrasound Pachymetry in Normal Eyes.

Authors:  Ayong Yu; Weiqi Zhao; Giacomo Savini; Zixu Huang; Fangjun Bao; Weicong Lu; Qinmei Wang; Jinhai Huang
Journal:  J Ophthalmol       Date:  2015-12-01       Impact factor: 1.909

6.  Comparison between Two Scheimpflug Anterior Segment Analyzers.

Authors:  Alireza Baradaran-Rafii; Tahmineh Motevasseli; Forouzan Yazdizadeh; Farid Karimian; Sahba Fekri; Amir Baradaran-Rafii
Journal:  J Ophthalmic Vis Res       Date:  2017 Jan-Mar

Review 7.  Galilei Corneal Tomography for Screening of Refractive Surgery Candidates: A Review of the Literature, Part II.

Authors:  Majid Moshirfar; Mahsaw N Motlagh; Michael S Murri; Hamed Momeni-Moghaddam; Yasmyne C Ronquillo; Phillip C Hoopes
Journal:  Med Hypothesis Discov Innov Ophthalmol       Date:  2019

8.  Single session, intrauser repeatability of anterior chamber biometric and corneal pachy-volumetric parameters using a new Scheimpflug+Placido device.

Authors:  Gaurav Prakash; Dhruv Srivastava
Journal:  J Optom       Date:  2015-09-01

9.  Repeatability and agreement of five imaging systems for measuring anterior segment parameters in healthy eyes.

Authors:  Mukesh Kumar; Rohit Shetty; Chaitra Jayadev; Harsha L Rao; Debarun Dutta
Journal:  Indian J Ophthalmol       Date:  2017-04       Impact factor: 1.848

10.  Study and characterization of morphogeometric parameters to assist diagnosis of keratoconus.

Authors:  Francisco Cavas-Martínez; Daniel G Fernández-Pacheco; Dolores Parras; Francisco J F Cañavate; Laurent Bataille; Jorge Alió
Journal:  Biomed Eng Online       Date:  2018-11-20       Impact factor: 2.819

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.