Literature DB >> 22153092

Central vault after phakic intraocular lens implantation: correlation with anterior chamber depth, white-to-white distance, spherical equivalent, and patient age.

José F Alfonso1, Luis Fernández-Vega, Carlos Lisa, Paulo Fernandes, Jorge Jorge, Robert Montés Micó.   

Abstract

PURPOSE: To compare the central postoperative vault of a phakic intraocular lens (pIOL) to correct myopia, myopic astigmatism, and hyperopia and identify ocular and lens parameters that might predict the vault amount.
SETTING: Fernández-Vega Ophthalmological Institute, Oviedo, Spain.
DESIGN: Cohort study.
METHODS: Three months after implantation of Implantable Collamer Lens pIOLs to correct myopia, hyperopia, and myopic astigmatism, central vault was measured using optical coherence tomography. Patients were divided into groups according to the preoperative anterior chamber depth (ACD) to compare the effects of ACD, white-to-white (WTW) distance, and lens diameter on postoperative pIOL vault.
RESULTS: Hyperopic pIOLs had statistically significantly lower vault followed by myopic pIOLs and toric pIOLs, which had a higher mean value and narrower range (260 to 860 μm). Measured vaults had a positive correlation with preoperative ACD (r = .32, P<.001) and WTW (r = .29, P<.001) and a negative correlation with preoperative spherical equivalent (SE) (r = -0.21, P<.001) and patient age (r = -0.12, P=.025). Eyes with a vault of 250 μm or less had a shallower ACD than eyes with a vault between 250 μm and 750 μm (mean difference -0.11 mm; P=.012) and those with a vault greater than 750 μm (mean difference -0.25 mm; P<.001).
CONCLUSIONS: Central vaulting was lower in hyperopic eyes. Current nomograms for pIOL diameter selection based on ACD and WTW might yield ideal vault and may have to be adjusted for older patients, shallower ACD, lower WTW, and lower SE.
Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22153092     DOI: 10.1016/j.jcrs.2011.07.035

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  14 in total

1.  Comparison of the measurements of a novel optical biometry: Nidek AL-Scan with Sirius and a ultrasound biometry.

Authors:  Çağatay Çağlar; Sücattin İlker Kocamış; Emre Demir; Mustafa Durmuş
Journal:  Int Ophthalmol       Date:  2016-07-08       Impact factor: 2.031

Review 2.  Analysis of perioperative problems related to intraocular Implantable Collamer Lens (ICL) implantation.

Authors:  Hao Zhang; Rui Gong; Xiaolan Zhang; Yingping Deng
Journal:  Int Ophthalmol       Date:  2022-06-22       Impact factor: 2.029

3.  Comparison of Vault Measurements Using a Swept-Source OCT-Based Optical Biometer and Anterior Segment OCT.

Authors:  Yali Du; Chuang Jin; Shengjie Yin; Geng Wang; Qian Ma; Yuancun Li; Binyao Chen; Hongxi Wang; Kunliang Qiu; Mingzhi Zhang
Journal:  Front Med (Lausanne)       Date:  2022-06-23

4.  Comparison of Anterior Segment Measurements with Scheimpflug/Placido Photography-Based Topography System and IOLMaster Partial Coherence Interferometry in Patients with Cataracts.

Authors:  Jinhai Huang; Na Liao; Giacomo Savini; Fangjun Bao; Ye Yu; Weicong Lu; Qingjie Hu; Qinmei Wang
Journal:  J Ophthalmol       Date:  2014-10-23       Impact factor: 1.909

Review 5.  Meta-analysis and review: effectiveness, safety, and central port design of the intraocular collamer lens.

Authors:  Mark Packer
Journal:  Clin Ophthalmol       Date:  2016-06-09

6.  Anterior Chamber Angle Evaluation following Phakic Posterior Chamber Collamer Lens with CentraFLOW and Its Correlation with ICL Vault and Intraocular Pressure.

Authors:  Sherif A Eissa; Sherin H Sadek; Mohamed W A El-Deeb
Journal:  J Ophthalmol       Date:  2016-12-08       Impact factor: 1.909

7.  Comparative analysis of the visual performance after implantation of the toric implantable collamer lens in stable keratoconus: a 4-year follow-up after sequential procedure (CXL+TICL implantation).

Authors:  Farideh Doroodgar; Feazollah Niazi; Azad Sanginabadi; Sana Niazi; Alireza Baradaran-Rafii; Cyrus Alinia; Eznollah Azargashb; Mohammad Ghoreishi
Journal:  BMJ Open Ophthalmol       Date:  2017-09-28

8.  Analysis of pre-operative factors affecting range of optimal vaulting after implantation of 12.6-mm V4c implantable collamer lens in myopic eyes.

Authors:  Hun Lee; David Sung Yong Kang; Jin Young Choi; Byoung Jin Ha; Eung Kweon Kim; Kyoung Yul Seo; Tae-Im Kim
Journal:  BMC Ophthalmol       Date:  2018-07-06       Impact factor: 2.209

9.  Three-dimensional non-parametric method for limbus detection.

Authors:  Ahmed Abass; Bernardo T Lopes; Ashkan Eliasy; Richard Wu; Steve Jones; John Clamp; Renato Ambrósio; Ahmed Elsheikh
Journal:  PLoS One       Date:  2018-11-26       Impact factor: 3.240

10.  Analysis of intraocular positions of posterior implantable collamer lens by full-scale ultrasound biomicroscopy.

Authors:  Xi Zhang; Xun Chen; Xiaoying Wang; Fei Yuan; Xingtao Zhou
Journal:  BMC Ophthalmol       Date:  2018-05-09       Impact factor: 2.209

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.