Literature DB >> 26624492

Comparison of Anterior Segment-Optical Coherence Tomography Parameters in Phacomorphic Angle Closure and Acute Angle Closure Eyes.

Sasan Moghimi1, Farshid Ramezani2, Mingguang He3, Anne L Coleman4, Shan C Lin5.   

Abstract

PURPOSE: The purpose of this study is to compare anterior segment-optical coherence tomography (AS-OCT) parameters in phacomorphic angle closure and acute primary angle closure (APAC) eyes.
METHODS: In this cross-sectional case series, a total of 134 patients with phacomorphic angle closure (28 eyes) or APAC (54 eyes), as well as normal control subjects (52 eyes), were enrolled. Patients underwent AS-OCT imaging and A-scan biometry of both eyes. Anterior chamber depth (ACD), anterior chamber area (ACA), iris thickness (IT), iris curvature, lens vault (LV), anterior vault (AV), and angle parameters including angle opening distance (AOD 500 and AOD750) and trabecular iris space area (TISA500 and TISA750) were measured in qualified images using the Zhongshan Angle Assessment Program and compared among eyes with phacomorphic angle closure, APAC, and normal control subjects.
RESULTS: Phacomorphic angle closure and APAC eyes had smaller AOD, ACD, ACA, ACW, AV, and posterior corneal arc length and greater LV than normal controls (P < 0.001 for all comparisons). After adjustment for age, sex, and pupil diameter, phacomorphic angle closure had greater AOD500 (P = 0.02), TISA500 (P = 0.003), TISA750 (P = 0.05), axial length (P = 0.03), and LV (P = 0.001) and less ACD (P = 0.001), ACA (P = 0.003), IT750 (P = 0.01), and IT2000 (P = 0.04) than APAC eyes: ACD < 1.59 mm (odds ratio [OR], 29.57; P < 0.01) and LV > 1042 μm (OR,12.12; P < 0.01) were the two biometric parameters that could highly discriminate phacomorphic angle closure from the APAC eyes. In multivariate analysis, ACD, LV, AOD500, and axial length could significantly distinguish the two entities.
CONCLUSIONS: Ocular biometric parameters can differentiate phacomorphic angle closure from APAC eyes. Shallower ACD and greater LV, axial length, and ACA are the main parameters that distinguish phacomorphic angle closure from APAC.

Entities:  

Mesh:

Year:  2015        PMID: 26624492     DOI: 10.1167/iovs.15-17336

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  9 in total

1.  Comparison of the measurements of a novel optical biometry: Nidek AL-Scan with Sirius and a ultrasound biometry.

Authors:  Çağatay Çağlar; Sücattin İlker Kocamış; Emre Demir; Mustafa Durmuş
Journal:  Int Ophthalmol       Date:  2016-07-08       Impact factor: 2.031

2.  Uveal effusion following acute primary angle-closure: a retrospective case series.

Authors:  Jian-Gang Yang; Jian-Jun Li; Hua Tian; Yan-Hong Li; Yu-Jing Gong; An-Le Su; Na He
Journal:  Int J Ophthalmol       Date:  2017-03-18       Impact factor: 1.779

3.  Non-contact tests for identifying people at risk of primary angle closure glaucoma.

Authors:  Anish Jindal; Irene Ctori; Gianni Virgili; Ersilia Lucenteforte; John G Lawrenson
Journal:  Cochrane Database Syst Rev       Date:  2020-05-28

4.  Associated factors of acute primary angle closure glaucoma in a sub-group of Chinese people: comparison between attack eyes and normal controls.

Authors:  Lifang Liu; Xinyu Liu; Chukai Huang; Geng Wang; Di Ma; Wanqi Zhang; Ce Zheng; Mingzhi Zhang
Journal:  Sci Rep       Date:  2017-11-02       Impact factor: 4.379

Review 5.  Efficacy and Safety of Argon Laser Peripheral Iridoplasty and Systemic Medical Therapy in Asian Patients with Acute Primary Angle Closure: A Meta-Analysis of Randomized Controlled Trials.

Authors:  Wenting Cai; Qiyang Lou; Jiaqi Fan; Donghui Yu; Tianyi Shen; Jing Yu
Journal:  J Ophthalmol       Date:  2019-05-02       Impact factor: 1.909

6.  Intraocular pressure changes after phacoemulsification in pseudoexfoliation versus healthy eyes.

Authors:  Farshid Ramezani; Mohammad Nazarian; Leila Rezaei
Journal:  BMC Ophthalmol       Date:  2021-05-06       Impact factor: 2.209

7.  Lens-vault analysis and its correlation with other biometric parameters using swept-source OCT.

Authors:  Pedro Tañá-Rivero; Ramón Ruiz-Mesa; Salvador Aguilar-Córcoles; Cristina Tello-Elordi; María Ramos-Alzamora; Robert Montés-Micó
Journal:  J Optom       Date:  2021-11-01

8.  Retinal and Choroidal Changes in Children with Moderate-to-High Hyperopia.

Authors:  Yu Qian; Yingyan Ma; Qiurong Lin; Zhaoyu Xiang; Jun Qiang; Yan Xu; Haidong Zou
Journal:  J Ophthalmol       Date:  2021-09-30       Impact factor: 1.909

9.  Anterior segment configuration as a predictive factor for refractive outcome after cataract surgery in patients with glaucoma.

Authors:  Young Cheong Kim; Mi Sun Sung; Hwan Heo; Sang Woo Park
Journal:  BMC Ophthalmol       Date:  2016-10-18       Impact factor: 2.209

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.