Literature DB >> 1564648

Sources of error in intraocular lens power calculation.

T Olsen1.   

Abstract

The hypothesis that the minimum error in predicted refraction after implantation of an intraocular lens (IOL) of calculated power is the sum of the random error in (1) the measurement of the axial length, (2) the measurement of the corneal power, and (3) the estimation of the pseudophakic anterior chamber depth (ACD) is proposed. Based on preoperative and postoperative biometry of 584 IOL implantations, 54% of the error was attributed to axial length errors, 8% to corneal power errors, and 38% to errors in the estimation of the postoperative ACD, when a fixed ACD was used in the IOL calculations. However, if the ACD was predicted according to a previously described regression method, the contribution of error from the ACD source was reduced to 22%, thereby reducing the total refractive prediction error from +/- 1.03 diopters (D) (+/- SD) to +/- 0.92 D (+/- SD). These predictions accord with clinical results.

Mesh:

Year:  1992        PMID: 1564648     DOI: 10.1016/s0886-3350(13)80917-0

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  74 in total

Review 1.  Recent advances in customising cataract surgery.

Authors:  Malcolm Woodcock; Sunil Shah; Ronald J Smith
Journal:  BMJ       Date:  2004-01-10

2.  IOLMaster biometry: refractive results of 100 consecutive cases.

Authors:  H Eleftheriadis
Journal:  Br J Ophthalmol       Date:  2003-08       Impact factor: 4.638

3.  Comparison of optical low-coherence reflectometry and applanation ultrasound biometry on intraocular lens power calculation.

Authors:  Mirjana Bjeloš Rončević; Mladen Bušić; Ivan Cima; Biljana Kuzmanović Elabjer; Damir Bosnar; Daliborka Miletić
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-09-18       Impact factor: 3.117

4.  Comparison of the measurements of a novel optical biometry: Nidek AL-Scan with Sirius and a ultrasound biometry.

Authors:  Çağatay Çağlar; Sücattin İlker Kocamış; Emre Demir; Mustafa Durmuş
Journal:  Int Ophthalmol       Date:  2016-07-08       Impact factor: 2.031

5.  Light-adjustable lens: development of in vitro nomograms.

Authors:  Daniel M Schwartz; Christian A Sandstedt; Shiao H Chang; Julie A Kornfield; Robert H Grubbs
Journal:  Trans Am Ophthalmol Soc       Date:  2004

6.  Relationship between the retinal thickness of the macula and the difference in axial length.

Authors:  Tetsuo Ueda; Yoshiaki Nawa; Yoshiaki Hara
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-08-13       Impact factor: 3.117

7.  Light-adjustable lens: customizing correction for multifocality and higher-order aberrations.

Authors:  Christian A Sandstedt; Shiao H Chang; Robert H Grubbs; Daniel M Schwartz
Journal:  Trans Am Ophthalmol Soc       Date:  2006

8.  Investigation of the stability of one-piece acrylic intraocular lenses in cataract surgery and in combined vitrectomy surgery.

Authors:  T Iwase; K Sugiyama
Journal:  Br J Ophthalmol       Date:  2006-08-16       Impact factor: 4.638

9.  Light-adjustable lens.

Authors:  Daniel M Schwartz
Journal:  Trans Am Ophthalmol Soc       Date:  2003

10.  Intraocular lens power calculation after corneal refractive surgery.

Authors:  Vahid Feiz
Journal:  Middle East Afr J Ophthalmol       Date:  2010-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.