Filipa Costa1, Sandra Sarmento1,2, Dora Gomes3, Helena Magalhães3, Rosário Arrais3, Graciete Moreira4, Maria Fátima Cruz4, José Pedro Silva5, Lúcio Santos5,6, Olga Sousa3. 1. 1 Medical Physics, Radiobiology and Radiation Protection Group, IPO Porto Research Center (CI-IPOP), Portuguese Oncology Institute of Porto (IPO Porto), Porto, Portugal. 2. 2 Medical Physics Department, Portuguese Oncology Institute of Porto (IPO Porto), Porto, Portugal. 3. 3 Radiation Oncology Department, Portuguese Oncology Institute of Porto (IPO Porto), Porto, Portugal. 4. 4 UCA, Portuguese Oncology Institute of Porto (IPO Porto), Porto, Portugal. 5. 5 Surgical Oncology Department, Portuguese Oncology Institute of Porto (IPO Porto), Porto, Portugal. 6. 6 Experimental Pathology and Therapeutics Group, IPO Porto Research Center (CI-IPOP), Portuguese Oncology Institute of Porto (IPO Porto), Porto, Portugal.
Abstract
OBJECTIVE: To characterize in vivo dose distributions during pelvic intraoperative electron radiation therapy (IOERT) for rectal cancer and to assess the alterations introduced by irregular irradiation surfaces in the presence of bevelled applicators. METHODS: In vivo measurements were performed with Gafchromic films during 32 IOERT procedures. 1 film per procedure was used for the first 20 procedures. The methodology was then optimized for the remaining 12 procedures by using a set of 3 films. Both the average dose and two-dimensional dose distributions for each film were determined. Phantom measurements were performed for comparison. RESULTS: For flat and concave surfaces, the doses measured in vivo agree with expected values. For concave surfaces with step-like irregularities, measured doses tend to be higher than expected doses. Results obtained with three films per procedure show a large variability along the irradiated surface, with important differences from expected profiles. These results are consistent with the presence of surface hotspots, such as those observed in phantoms in the presence of step-like irregularities, as well as fluid build-up. CONCLUSION: Clinical dose distributions in the IOERT of rectal cancer are often different from the references used for prescription. Further studies are necessary to assess the impact of these differences on treatment outcomes. In vivo measurements are important, but need to be accompanied by accurate imaging of positioning and irradiated surfaces. ADVANCES IN KNOWLEDGE: These results confirm that surface irregularities occur frequently in rectal cancer IOERT and have a measurable effect on the dose distribution.
OBJECTIVE: To characterize in vivo dose distributions during pelvic intraoperative electron radiation therapy (IOERT) for rectal cancer and to assess the alterations introduced by irregular irradiation surfaces in the presence of bevelled applicators. METHODS: In vivo measurements were performed with Gafchromic films during 32 IOERT procedures. 1 film per procedure was used for the first 20 procedures. The methodology was then optimized for the remaining 12 procedures by using a set of 3 films. Both the average dose and two-dimensional dose distributions for each film were determined. Phantom measurements were performed for comparison. RESULTS: For flat and concave surfaces, the doses measured in vivo agree with expected values. For concave surfaces with step-like irregularities, measured doses tend to be higher than expected doses. Results obtained with three films per procedure show a large variability along the irradiated surface, with important differences from expected profiles. These results are consistent with the presence of surface hotspots, such as those observed in phantoms in the presence of step-like irregularities, as well as fluid build-up. CONCLUSION: Clinical dose distributions in the IOERT of rectal cancer are often different from the references used for prescription. Further studies are necessary to assess the impact of these differences on treatment outcomes. In vivo measurements are important, but need to be accompanied by accurate imaging of positioning and irradiated surfaces. ADVANCES IN KNOWLEDGE: These results confirm that surface irregularities occur frequently in rectal cancer IOERT and have a measurable effect on the dose distribution.
Authors: Stefan J van Hoof; Patrick V Granton; Guillaume Landry; Mark Podesta; Frank Verhaegen Journal: Phys Med Biol Date: 2012-06-15 Impact factor: 3.609
Authors: J R Palta; P J Biggs; J D Hazle; M S Huq; R A Dahl; T G Ochran; J Soen; R R Dobelbower; E C McCullough Journal: Int J Radiat Oncol Biol Phys Date: 1995-10-15 Impact factor: 7.038
Authors: Verónica García-Vázquez; Begoña Sesé-Lucio; Felipe A Calvo; Juan J Vaquero; Manuel Desco; Javier Pascau Journal: Radiat Oncol Date: 2018-12-07 Impact factor: 3.481
Authors: Verónica García-Vázquez; Felipe A Calvo; María J Ledesma-Carbayo; Claudio V Sole; José Calvo-Haro; Manuel Desco; Javier Pascau Journal: PLoS One Date: 2020-01-10 Impact factor: 3.240