In vivo dosimetry using Gafchromic films during pelvic intraoperative electron radiation therapy (IOERT).

Filipa Costa1, Sandra Sarmento1,2, Dora Gomes3, Helena Magalhães3, Rosário Arrais3, Graciete Moreira4, Maria Fátima Cruz4, José Pedro Silva5, Lúcio Santos5,6, Olga Sousa3.   

Abstract

OBJECTIVE: To characterize in vivo dose distributions during pelvic intraoperative electron radiation therapy (IOERT) for rectal cancer and to assess the alterations introduced by irregular irradiation surfaces in the presence of bevelled applicators.
METHODS: In vivo measurements were performed with Gafchromic films during 32 IOERT procedures. 1 film per procedure was used for the first 20 procedures. The methodology was then optimized for the remaining 12 procedures by using a set of 3 films. Both the average dose and two-dimensional dose distributions for each film were determined. Phantom measurements were performed for comparison.
RESULTS: For flat and concave surfaces, the doses measured in vivo agree with expected values. For concave surfaces with step-like irregularities, measured doses tend to be higher than expected doses. Results obtained with three films per procedure show a large variability along the irradiated surface, with important differences from expected profiles. These results are consistent with the presence of surface hotspots, such as those observed in phantoms in the presence of step-like irregularities, as well as fluid build-up.
CONCLUSION: Clinical dose distributions in the IOERT of rectal cancer are often different from the references used for prescription. Further studies are necessary to assess the impact of these differences on treatment outcomes. In vivo measurements are important, but need to be accompanied by accurate imaging of positioning and irradiated surfaces. ADVANCES IN KNOWLEDGE: These results confirm that surface irregularities occur frequently in rectal cancer IOERT and have a measurable effect on the dose distribution.

Entities:  

Mesh:

Year:  2016        PMID: 27188847      PMCID: PMC5257329          DOI: 10.1259/bjr.20160193

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  20 in total

1.  Evaluation of a novel triple-channel radiochromic film analysis procedure using EBT2.

Authors:  Stefan J van Hoof; Patrick V Granton; Guillaume Landry; Mark Podesta; Frank Verhaegen
Journal:  Phys Med Biol       Date:  2012-06-15       Impact factor: 3.609

Review 2.  Radiochromic film dosimetry: past, present, and future.

Authors:  Slobodan Devic
Journal:  Phys Med       Date:  2010-11-02       Impact factor: 2.685

3.  Dosimetric accuracy of Gafchromic EBT2 and EBT3 film for in vivo dosimetry.

Authors:  Rebecca Moylan; Trent Aland; Tanya Kairn
Journal:  Australas Phys Eng Sci Med       Date:  2013-06-26       Impact factor: 1.430

4.  Setup verification and in vivo dosimetry during intraoperative radiation therapy (IORT) for prostate cancer.

Authors:  Antonella Soriani; Valeria Landoni; Simona Marzi; Giuseppe Iaccarino; Biancamaria Saracino; Giorgio Arcangeli; Marcello Benassi
Journal:  Med Phys       Date:  2007-08       Impact factor: 4.071

5.  Dosimetry characteristics of GAFCHROMIC EBT film responding to therapeutic electron beams.

Authors:  Fan-Chi Su; Yaxi Liu; Sotirios Stathakis; Chengyu Shi; Carlos Esquivel; Niko Papanikolaou
Journal:  Appl Radiat Isot       Date:  2007-05-29       Impact factor: 1.513

6.  Assessment of clinically relevant dose distributions in pelvic IOERT using Gafchromic EBT3 films.

Authors:  Filipa Costa; Sandra Sarmento; Olga Sousa
Journal:  Phys Med       Date:  2015-06-12       Impact factor: 2.685

7.  Calibrating page sized Gafchromic EBT3 films.

Authors:  W Crijns; F Maes; U A van der Heide; F Van den Heuvel
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

8.  Evaluation of Gafchromic® EBT3 films characteristics in therapy photon, electron and proton beams.

Authors:  J Sorriaux; A Kacperek; S Rossomme; J A Lee; D Bertrand; S Vynckier; E Sterpin
Journal:  Phys Med       Date:  2012-10-26       Impact factor: 2.685

9.  Intraoperative electron beam radiation therapy: technique, dosimetry, and dose specification: report of task force 48 of the Radiation Therapy Committee, American Association of Physicists in Medicine.

Authors:  J R Palta; P J Biggs; J D Hazle; M S Huq; R A Dahl; T G Ochran; J Soen; R R Dobelbower; E C McCullough
Journal:  Int J Radiat Oncol Biol Phys       Date:  1995-10-15       Impact factor: 7.038

10.  In vivo dosimetry and shielding disk alignment verification by EBT3 GAFCHROMIC film in breast IOERT treatment.

Authors:  Mara Severgnini; Mario de Denaro; Marina Bortul; Cristiana Vidali; Aulo Beorchia
Journal:  J Appl Clin Med Phys       Date:  2014-01-08       Impact factor: 2.102

View more
  3 in total

1.  Surface scanning for 3D dose calculation in intraoperative electron radiation therapy.

Authors:  Verónica García-Vázquez; Begoña Sesé-Lucio; Felipe A Calvo; Juan J Vaquero; Manuel Desco; Javier Pascau
Journal:  Radiat Oncol       Date:  2018-12-07       Impact factor: 3.481

2.  Intraoperative computed tomography imaging for dose calculation in intraoperative electron radiation therapy: Initial clinical observations.

Authors:  Verónica García-Vázquez; Felipe A Calvo; María J Ledesma-Carbayo; Claudio V Sole; José Calvo-Haro; Manuel Desco; Javier Pascau
Journal:  PLoS One       Date:  2020-01-10       Impact factor: 3.240

3.  Dosimetric properties of a newly developed thermoluminescent sheet-type dosimeter for clinical proton beams.

Authors:  Takahiro Kato; Tatsuhiko Sagara; Shinya Komori; Ryohei Kato; Akihiko Takeuchi; Yuki Narita
Journal:  J Appl Clin Med Phys       Date:  2021-03-15       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.