Literature DB >> 7558965

Intraoperative electron beam radiation therapy: technique, dosimetry, and dose specification: report of task force 48 of the Radiation Therapy Committee, American Association of Physicists in Medicine.

J R Palta1, P J Biggs, J D Hazle, M S Huq, R A Dahl, T G Ochran, J Soen, R R Dobelbower, E C McCullough.   

Abstract

Intraoperative radiation therapy (IORT) is a treatment modality whereby a large single dose of radiation is delivered to a surgically open, exposed cancer site. Typically, a beam of megavoltage electrons is directed at an exposed tumor or tumor bed through a specially designed applicator system. In the last few years, IORT facilities have proliferated around the world. The IORT technique and the applicator systems used at these facilities vary greatly in sophistication and design philosophy. The IORT beam characteristics vary for different designs of applicator systems. It is necessary to document the existing techniques of IORT, to detail the dosimetry data required for accurate delivery of the prescribed dose, and to have a uniform method of dose specification for cooperative clinical trials. The specific charge to the task group includes the following: (a) identify the multidisciplinary IORT team, (b) outline special considerations that must be addressed by an IORT program, (c) review currently available IORT techniques, (d) describe dosimetric measurements necessary for accurate delivery of prescribed dose, (e) describe dosimetric measurements necessary in documenting doses to the surrounding normal tissues, (f) recommend quality assurance procedures for IORT, (g) review methods of treatment documentation and verification, and (h) recommend methods of dose specification and recording for cooperative clinical trials.

Entities:  

Mesh:

Year:  1995        PMID: 7558965     DOI: 10.1016/0360-3016(95)00280-C

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  10 in total

1.  Practical issues regarding angular and energy response in in vivo intraoperative electron radiotherapy dosimetry.

Authors:  Juan López-Tarjuelo; Ana Bouché-Babiloni; Virginia Morillo-Macías; Agustín Santos-Serra; Carlos Ferrer-Albiach
Journal:  Rep Pract Oncol Radiother       Date:  2016-10-19

2.  In vivo dosimetry using Gafchromic films during pelvic intraoperative electron radiation therapy (IOERT).

Authors:  Filipa Costa; Sandra Sarmento; Dora Gomes; Helena Magalhães; Rosário Arrais; Graciete Moreira; Maria Fátima Cruz; José Pedro Silva; Lúcio Santos; Olga Sousa
Journal:  Br J Radiol       Date:  2016-05-18       Impact factor: 3.039

3.  Attenuation measurements show that the presence of a TachoSil surgical patch will not compromise target irradiation in intra-operative electron radiation therapy or high-dose-rate brachytherapy.

Authors:  Sandra Sarmento; Filipa Costa; Alexandre Pereira; Joana Lencart; Anabela Dias; Luís Cunha; Olga Sousa; José Pedro Silva; Lúcio Santos
Journal:  Radiat Oncol       Date:  2015-01-09       Impact factor: 3.481

4.  Implementation of an intraoperative electron radiotherapy in vivo dosimetry program.

Authors:  Juan López-Tarjuelo; Virginia Morillo-Macías; Ana Bouché-Babiloni; Enrique Boldó-Roda; Rafael Lozoya-Albacar; Carlos Ferrer-Albiach
Journal:  Radiat Oncol       Date:  2016-03-15       Impact factor: 3.481

5.  Design and dosimetry characteristics of a commercial applicator system for intra-operative electron beam therapy utilizing ELEKTA Precise accelerator.

Authors:  Alexander Nevelsky; Zvi Bernstein; Raquel Bar-Deroma; Abraham Kuten; Itzhak Orion
Journal:  J Appl Clin Med Phys       Date:  2010-07-19       Impact factor: 2.102

6.  Commissioning, clinical implementation, and performance of the Mobetron 2000 for intraoperative radiation therapy.

Authors:  Landon S Wootton; Juergen Meyer; Edward Kim; Mark Phillips
Journal:  J Appl Clin Med Phys       Date:  2017-01       Impact factor: 2.102

Review 7.  Present state and issues in IORT Physics.

Authors:  Frank W Hensley
Journal:  Radiat Oncol       Date:  2017-01-27       Impact factor: 3.481

8.  Comparing the dosimetric characteristics of the electron beam from dedicated intraoperative and conventional radiotherapy accelerators.

Authors:  Hamid Reza Baghani; Seyed Mahmoud Reza Aghamiri; Seyed Rabi Mahdavi; Mohammad Esmail Akbari; Hamid Reza Mirzaei
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

9.  Dose consumption for quality assurance and maintenance at a dedicated IORT accelerator.

Authors:  Frank W Hensley
Journal:  J Appl Clin Med Phys       Date:  2009-10-27       Impact factor: 2.102

10.  Commissioning of a mobile electron accelerator for intraoperative radiotherapy.

Authors:  M D Mills; L C Fajardo; D L Wilson; J L Daves; W J Spanos
Journal:  J Appl Clin Med Phys       Date:  2001       Impact factor: 2.102

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.