Dosimetry characteristics of GAFCHROMIC EBT film responding to therapeutic electron beams.

Fan-Chi Su1, Yaxi Liu, Sotirios Stathakis, Chengyu Shi, Carlos Esquivel, Niko Papanikolaou.   

Abstract

For the last 50 years, high-energy electron beams have been used mainly for treatment of superficial targets. Accordingly, two-dimensional (2D) measurements are required to determine the margin between the surface and protected normal tissues in high-dose-gradient regions. As recommended by the AAPM, 2D electron beam dosimetry should be conducted primarily with films because of their high spatial resolution and because of the fact that they produce permanent records. In this work, the dosimetric characteristics of a newly developed radiochromic film, GAFCHROMIC EBT film were used to study treatment parameters for therapeutic electron beams. The dose-response curve was found to be weakly dependent on the electron beam energy (within +/-4%). The effect of fractionation, as well as electron beam dose rate, had small influence on the calibration curve of EBT films (+/-2.5% and 2%, respectively). For the investigated range of depth, dose-response curves are nearly independent of the calibration depth. As for the cone size dependence, we found that it is accurate to calibrate GAFCHROMIC EBT films using a 10 x 10 cm(2) cone and apply this calibration to other cone sizes.

Entities:  

Mesh:

Year:  2007        PMID: 17590344     DOI: 10.1016/j.apradiso.2007.05.005

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  11 in total

1.  In vivo dosimetry using Gafchromic films during pelvic intraoperative electron radiation therapy (IOERT).

Authors:  Filipa Costa; Sandra Sarmento; Dora Gomes; Helena Magalhães; Rosário Arrais; Graciete Moreira; Maria Fátima Cruz; José Pedro Silva; Lúcio Santos; Olga Sousa
Journal:  Br J Radiol       Date:  2016-05-18       Impact factor: 3.039

2.  Dose verification of helical tomotherapy intensity modulated radiation therapy planning using 2D-array ion chambers.

Authors:  S Xu; C Xie; Z Ju; X Dai; H Gong; L Wang; J Yang
Journal:  Biomed Imaging Interv J       Date:  2010-04-01

3.  Use of new radiochromic devices for peripheral dose measurement: potential in-vivo dosimetry application.

Authors:  S-T Chiu-Tsao; Mf Chan
Journal:  Biomed Imaging Interv J       Date:  2009-10-01

4.  Linearization of dose-response curve of the radiochromic film dosimetry system.

Authors:  Slobodan Devic; Nada Tomic; Saad Aldelaijan; Francois Deblois; Jan Seuntjens; Maria F Chan; Dave Lewis
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.506

5.  An efficient protocol for radiochromic film dosimetry combining calibration and measurement in a single scan.

Authors:  David Lewis; Andre Micke; Xiang Yu; Maria F Chan
Journal:  Med Phys       Date:  2012-10       Impact factor: 4.506

6.  Is It Possible to Publish a Calibration Function for Radiochromic Film?

Authors:  Maria F Chan; David Lewis; Xiang Yu
Journal:  Int J Med Phys Clin Eng Radiat Oncol       Date:  2014-01-29

7.  Small field electron beam dosimetry using MOSFET detector.

Authors:  Md Nurul Amin; Robert Heaton; Bern Norrlinger; Mohammad K Islam
Journal:  J Appl Clin Med Phys       Date:  2010-10-04       Impact factor: 2.102

8.  Dosimetric perturbation from cloth and paper gowns for total skin electron irradiation.

Authors:  James P Steinman; Shane L Hopkins; Iris Z Wang
Journal:  J Appl Clin Med Phys       Date:  2013-07-08       Impact factor: 2.102

9.  Experimental assessment of out-of-field dose components in high energy electron beams used in external beam radiotherapy.

Authors:  Mohamad M Alabdoaburas; Jean-Pierre Mege; Jean Chavaudra; Jérémi Vũ Bezin; Atilla Veres; Florent de Vathaire; Dimitri Lefkopoulos; Ibrahima Diallo
Journal:  J Appl Clin Med Phys       Date:  2015-11-08       Impact factor: 2.102

10.  Suitability of radiochromic films for dosimetry of very-low energy X-rays.

Authors:  Martin A Ebert; Ali H Asad; Salim A Siddiqui
Journal:  J Appl Clin Med Phys       Date:  2009-09-02       Impact factor: 2.102

View more