Literature DB >> 27097790

Automatic spectral imaging protocol selection and iterative reconstruction in abdominal CT with reduced contrast agent dose: initial experience.

Peijie Lv1, Jie Liu1, Yaru Chai1, Xiaopeng Yan1, Jianbo Gao2, Junqiang Dong1.   

Abstract

OBJECTIVE: To evaluate the feasibility, image quality, and radiation dose of automatic spectral imaging protocol selection (ASIS) and adaptive statistical iterative reconstruction (ASIR) with reduced contrast agent dose in abdominal multiphase CT.
METHODS: One hundred and sixty patients were randomly divided into two scan protocols (n = 80 each; protocol A, 120 kVp/450 mgI/kg, filtered back projection algorithm (FBP); protocol B, spectral CT imaging with ASIS and 40 to 70 keV monochromatic images generated per 300 mgI/kg, ASIR algorithm. Quantitative parameters (image noise and contrast-to-noise ratios [CNRs]) and qualitative visual parameters (image noise, small structures, organ enhancement, and overall image quality) were compared.
RESULTS: Monochromatic images at 50 keV and 60 keV provided similar or lower image noise, but higher contrast and overall image quality as compared with 120-kVp images. Despite the higher image noise, 40-keV images showed similar overall image quality compared to 120-kVp images. Radiation dose did not differ between the two protocols, while contrast agent dose in protocol B was reduced by 33 %.
CONCLUSION: Application of ASIR and ASIS to monochromatic imaging from 40 to 60 keV allowed contrast agent dose reduction with adequate image quality and without increasing radiation dose compared to 120 kVp with FBP. KEY POINTS: • Automatic spectral imaging protocol selection provides appropriate scan protocols. • Abdominal CT is feasible using spectral imaging and 300 mgI/kg contrast agent. • 50-keV monochromatic images with 50 % ASIR provide optimal image quality.

Entities:  

Keywords:  Contrast agent; Dual-energy CT; Iterative reconstruction; Monochromatic image; Spectral CT

Mesh:

Substances:

Year:  2016        PMID: 27097790     DOI: 10.1007/s00330-016-4349-8

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  34 in total

1.  Low contrast agent and radiation dose protocol for hepatic dynamic CT of thin adults at 256-detector row CT: effect of low tube voltage and hybrid iterative reconstruction algorithm on image quality.

Authors:  Takeshi Nakaura; Shinichi Nakamura; Natsuki Maruyama; Yoshinori Funama; Kazuo Awai; Kazunori Harada; Shouzaburou Uemura; Yasuyuki Yamashita
Journal:  Radiology       Date:  2012-05-24       Impact factor: 11.105

Review 2.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

Review 3.  Recent developments of dual-energy CT in oncology.

Authors:  David Simons; Marc Kachelriess; Heinz-Peter Schlemmer
Journal:  Eur Radiol       Date:  2014-01-09       Impact factor: 5.315

4.  Acute renal failure after coronary intervention: incidence, risk factors, and relationship to mortality.

Authors:  P A McCullough; R Wolyn; L L Rocher; R N Levin; W W O'Neill
Journal:  Am J Med       Date:  1997-11       Impact factor: 4.965

Review 5.  Contrast-media-induced nephrotoxicity: a consensus report. Contrast Media Safety Committee, European Society of Urogenital Radiology (ESUR).

Authors:  S K Morcos; H S Thomsen; J A Webb
Journal:  Eur Radiol       Date:  1999       Impact factor: 5.315

6.  Virtual monochromatic spectral imaging with fast kilovoltage switching: improved image quality as compared with that obtained with conventional 120-kVp CT.

Authors:  Kazuhiro Matsumoto; Masahiro Jinzaki; Yutaka Tanami; Akihisa Ueno; Minoru Yamada; Sachio Kuribayashi
Journal:  Radiology       Date:  2011-02-17       Impact factor: 11.105

7.  Abdominal CT: comparison of adaptive statistical iterative and filtered back projection reconstruction techniques.

Authors:  Sarabjeet Singh; Mannudeep K Kalra; Jiang Hsieh; Paul E Licato; Synho Do; Homer H Pien; Michael A Blake
Journal:  Radiology       Date:  2010-09-09       Impact factor: 11.105

8.  Aortic and hepatic enhancement and tumor-to-liver contrast: analysis of the effect of different concentrations of contrast material at multi-detector row helical CT.

Authors:  Kazuo Awai; Koichi Takada; Hiromitsu Onishi; Shinichi Hori
Journal:  Radiology       Date:  2002-09       Impact factor: 11.105

9.  Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight.

Authors:  Kazuo Awai; Kumiko Hiraishi; Shinichi Hori
Journal:  Radiology       Date:  2004-01       Impact factor: 11.105

10.  Contrast agent and radiation dose reduction in abdominal CT by a combination of low tube voltage and advanced image reconstruction algorithms.

Authors:  Nico Buls; Gert Van Gompel; Toon Van Cauteren; Koenraad Nieboer; Inneke Willekens; Guy Verfaillie; Paul Evans; Sven Macholl; Ben Newton; Johan de Mey
Journal:  Eur Radiol       Date:  2014-11-29       Impact factor: 5.315

View more
  16 in total

1.  Can virtual monochromatic images from dual-energy CT replace low-kVp images for abdominal contrast-enhanced CT in small- and medium-sized patients?

Authors:  Peijie Lv; Zhigang Zhou; Jie Liu; Yaru Chai; Huiping Zhao; Hua Guo; Daniele Marin; Jianbo Gao
Journal:  Eur Radiol       Date:  2018-11-30       Impact factor: 5.315

2.  Quantifying potential reduction in contrast dose with monoenergetic images synthesized from dual-layer detector spectral CT.

Authors:  Derek S Tsang; Thomas E Merchant; Sophie E Merchant; Hanna Smith; Yoad Yagil; Chia-Ho Hua
Journal:  Br J Radiol       Date:  2017-07-27       Impact factor: 3.039

3.  Iterative reconstruction in single-source dual-energy CT angiography: feasibility of low and ultra-low volume contrast medium protocols.

Authors:  Ping Hou; Xiangnan Feng; Jie Liu; Yue Zhou; Yaojun Jiang; Xiaochen Jiang; Jianbo Gao
Journal:  Br J Radiol       Date:  2017-06-23       Impact factor: 3.039

4.  Using 80 kVp on a 320-row scanner for hepatic multiphasic CT reduces the contrast dose by 50 % in patients at risk for contrast-induced nephropathy.

Authors:  Narumi Taguchi; Seitaro Oda; Daisuke Utsunomiya; Yoshinori Funama; Takeshi Nakaura; Masanori Imuta; Sadahiro Yamamura; Hideaki Yuki; Masafumi Kidoh; Kenichiro Hirata; Tomohiro Namimoto; Masahiro Hatemura; Noriyuki Kai; Yasuyuki Yamashita
Journal:  Eur Radiol       Date:  2016-05-30       Impact factor: 5.315

5.  Contrast agent concentration optimization in CTA using low tube voltage and dual-energy CT in multiple vendors: a phantom study.

Authors:  Robbert W van Hamersvelt; Nienke G Eijsvoogel; Casper Mihl; Pim A de Jong; Arnold M R Schilham; Nico Buls; Marco Das; Tim Leiner; Martin J Willemink
Journal:  Int J Cardiovasc Imaging       Date:  2018-03-08       Impact factor: 2.357

6.  Subtraction CT angiography in head and neck with low radiation and contrast dose dual-energy spectral CT using rapid kV-switching technique.

Authors:  Guangming Ma; Yong Yu; Haifeng Duan; Yuequn Dou; Yongjun Jia; Xirong Zhang; Chuangbo Yang; Xiaoxia Chen; Dong Han; Changyi Guo; Taiping He
Journal:  Br J Radiol       Date:  2018-03-07       Impact factor: 3.039

7.  Dual-layer DECT for multiphasic hepatic CT with 50 percent iodine load: a matched-pair comparison with a 120 kVp protocol.

Authors:  Yasunori Nagayama; Takeshi Nakaura; Seitaro Oda; Daisuke Utsunomiya; Yoshinori Funama; Yuji Iyama; Narumi Taguchi; Tomohiro Namimoto; Hideaki Yuki; Masafumi Kidoh; Kenichiro Hirata; Masataka Nakagawa; Yasuyuki Yamashita
Journal:  Eur Radiol       Date:  2017-10-23       Impact factor: 5.315

8.  Automatic spectral imaging protocol selection combined with iterative reconstruction can enhance image quality and decrease radiation and contrast dosage in abdominal CT angiography.

Authors:  Xiao-Ping Yin; Bu-Lang Gao; Cai-Ying Li; Zi-Wei Zuo; Ying-Jin Xu; Jia-Ning Wang; Huai-Jun Liu; Guang-Lu Liang
Journal:  Jpn J Radiol       Date:  2018-04-03       Impact factor: 2.374

9.  Automatic spectral imaging protocol and iterative reconstruction for radiation dose reduction in typical hepatic hemangioma computed tomography with reduced iodine load: a preliminary study.

Authors:  Wei Li; Aiyin Li; Bin Wang; Xiuyuan Niu; Xin Cao; Xinyi Wang; Hao Shi
Journal:  Br J Radiol       Date:  2018-05-17       Impact factor: 3.039

10.  Comparison of image quality and radiation exposure between conventional imaging and gemstone spectral imaging in abdominal CT examination.

Authors:  Tianqi Fang; Wei Deng; Martin Wai-Ming Law; Liangping Luo; Liyun Zheng; Ying Guo; Hanwei Chen; Bingsheng Huang
Journal:  Br J Radiol       Date:  2018-06-01       Impact factor: 3.039

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.