Literature DB >> 29516228

Contrast agent concentration optimization in CTA using low tube voltage and dual-energy CT in multiple vendors: a phantom study.

Robbert W van Hamersvelt1, Nienke G Eijsvoogel2, Casper Mihl2, Pim A de Jong3, Arnold M R Schilham3, Nico Buls4, Marco Das2, Tim Leiner3, Martin J Willemink3.   

Abstract

We investigated the feasibility and extent to which iodine concentration can be reduced in computed tomography angiography imaging of the aorta and coronary arteries using low tube voltage and virtual monochromatic imaging of 3 major dual-energy CT (DECT) vendors. A circulation phantom was imaged with dual source CT (DSCT), gemstone spectral imaging (GSI) and dual-layer spectral detector CT (SDCT). For each scanner, a reference scan was acquired at 120 kVp using routine iodine concentration (300 mg I/ml). Subsequently, scans were acquired at lowest possible tube potential (70, 80, 80 kVp, respectively), and DECT-mode (80/150Sn, 80/140 and 120 kVp, respectively) in arterial phase after administration of iodine (300, 240, 180, 120, 60, 30 mg I/ml). Objective image quality was evaluated using attenuation, CNR and dose corrected CNR (DCCNR) measured in the aorta and left main coronary artery. Average DCCNR at reference was 227.0, 39.7 and 60.2 for DSCT, GSI and SDCT. Maximum iodine concentration reduction without loss of DCCNR was feasible down to 180 mg I/ml (40% reduced) for DSCT (DCCNR 467.1) and GSI (DCCNR 46.1) using conventional CT low kVp, and 120 mg I/ml (60% reduced) for SDCT (DCCNR 171.5) using DECT mode. Low kVp scanning and DECT allows for 40-60% iodine reduction without loss in image quality compared to reference. Optimal scan protocol and to which extent varies per vendor. Further patient studies are needed to extend and translate our findings to clinical practice.

Entities:  

Keywords:  Dual-energy CT; Image quality; Iodinated contrast media; Low kVp; Thoracic aorta

Mesh:

Substances:

Year:  2018        PMID: 29516228     DOI: 10.1007/s10554-018-1329-x

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  30 in total

1.  Low tube voltage dual source computed tomography to reduce contrast media doses in adult abdomen examinations: A phantom study.

Authors:  Daniel Thor; Torkel B Brismar; Michael A Fischer
Journal:  Med Phys       Date:  2015-09       Impact factor: 4.071

2.  Prospective comparison of dual-energy CT aortography using 70% reduced iodine dose versus single-energy CT aortography using standard iodine dose in the same patient.

Authors:  William P Shuman; Ryan B O'Malley; Janet M Busey; Mario M Ramos; Kent M Koprowicz
Journal:  Abdom Radiol (NY)       Date:  2017-03

3.  Monochromatic image reconstruction by dual energy imaging allows half iodine load computed tomography coronary angiography.

Authors:  Patricia Carrascosa; Jonathon A Leipsic; Carlos Capunay; Alejandro Deviggiano; Javier Vallejos; Alejandro Goldsmit; Gaston A Rodriguez-Granillo
Journal:  Eur J Radiol       Date:  2015-06-24       Impact factor: 3.528

4.  Objective characterization of GE discovery CT750 HD scanner: gemstone spectral imaging mode.

Authors:  Da Zhang; Xinhua Li; Bob Liu
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

5.  Effect of reduced x-ray tube voltage, low iodine concentration contrast medium, and sinogram-affirmed iterative reconstruction on image quality and radiation dose at coronary CT angiography: results of the prospective multicenter REALISE trial.

Authors:  Wei-Hua Yin; Bin Lu; Jian-Bo Gao; Pei-Ling Li; Kai Sun; Zhi-Feng Wu; Wen-Jie Yang; Xiao-Qin Zhang; Min-Wen Zheng; Andrew D McQuiston; Felix G Meinel; Uwe Joseph Schoepf
Journal:  J Cardiovasc Comput Tomogr       Date:  2015-01-22

Review 6.  New Applications of Cardiac Computed Tomography: Dual-Energy, Spectral, and Molecular CT Imaging.

Authors:  Ibrahim Danad; Zahi A Fayad; Martin J Willemink; James K Min
Journal:  JACC Cardiovasc Imaging       Date:  2015-06

7.  Image fusion in dual energy computed tomography for detection of hypervascular liver hepatocellular carcinoma: phantom and preliminary studies.

Authors:  Kyung Su Kim; Jeong Min Lee; Seung Ho Kim; Kyung Won Kim; Soo Jin Kim; Seung Hyun Cho; Joon Koo Han; Byung Ihn Choi
Journal:  Invest Radiol       Date:  2010-03       Impact factor: 6.016

8.  Maximizing Iodine Contrast-to-Noise Ratios in Abdominal CT Imaging through Use of Energy Domain Noise Reduction and Virtual Monoenergetic Dual-Energy CT.

Authors:  Shuai Leng; Lifeng Yu; Joel G Fletcher; Cynthia H McCollough
Journal:  Radiology       Date:  2015-04-10       Impact factor: 11.105

9.  Contrast agent and radiation dose reduction in abdominal CT by a combination of low tube voltage and advanced image reconstruction algorithms.

Authors:  Nico Buls; Gert Van Gompel; Toon Van Cauteren; Koenraad Nieboer; Inneke Willekens; Guy Verfaillie; Paul Evans; Sven Macholl; Ben Newton; Johan de Mey
Journal:  Eur Radiol       Date:  2014-11-29       Impact factor: 5.315

10.  Accuracy of iodine quantification using dual energy CT in latest generation dual source and dual layer CT.

Authors:  Gert Jan Pelgrim; Robbert W van Hamersvelt; Martin J Willemink; Bernhard T Schmidt; Thomas Flohr; Arnold Schilham; Julien Milles; Matthijs Oudkerk; Tim Leiner; Rozemarijn Vliegenthart
Journal:  Eur Radiol       Date:  2017-02-06       Impact factor: 5.315

View more
  16 in total

Review 1.  Lower extremity CT angiography in peripheral arterial disease: from the established approach to evolving technical developments.

Authors:  Omar Shwaiki; Basem Rashwan; Matthias A Fink; Levester Kirksey; Sameer Gadani; Karunakaravel Karuppasamy; Claudius Melzig; Dustin Thompson; Giuseppe D'Amico; Fabian Rengier; Sasan Partovi
Journal:  Int J Cardiovasc Imaging       Date:  2021-05-17       Impact factor: 2.357

2.  Personalized administration of contrast medium with high delivery rate in low tube voltage coronary computed tomography angiography.

Authors:  Sock Keow Tan; Kwan Hoong Ng; Chai Hong Yeong; Raja Rizal Azman Raja Aman; Fadhli Mohamed Sani; Yang Faridah Abdul Aziz; Zhonghua Sun
Journal:  Quant Imaging Med Surg       Date:  2019-04

3.  Virtual monoenergetic images preserve diagnostic assessability in contrast media reduced abdominal spectral detector CT.

Authors:  Simon Lennartz; Nils Große Hokamp; Charlotte Zäske; David Zopfs; Grischa Bratke; Andreas Glauner; David Maintz; Thorsten Persigehl; De-Hua Chang; Tilman Hickethier
Journal:  Br J Radiol       Date:  2020-07-24       Impact factor: 3.039

4.  Dual-Energy CT Images: Pearls and Pitfalls.

Authors:  Anushri Parakh; Simon Lennartz; Chansik An; Prabhakar Rajiah; Benjamin M Yeh; Frank J Simeone; Dushyant V Sahani; Avinash R Kambadakone
Journal:  Radiographics       Date:  2021 Jan-Feb       Impact factor: 5.333

5.  Reducing contrast dose using virtual monoenergetic imaging for aortic CTA.

Authors:  Ryoichi Yoshida; Keisuke Usui; Yasushi Katsunuma; Hiroshi Honda; Koki Hatakeyama
Journal:  J Appl Clin Med Phys       Date:  2020-07-02       Impact factor: 2.102

6.  In vitro optimization and comparison of CT angiography versus radial cardiovascular magnetic resonance for the quantification of cross-sectional areas and coronary endothelial function.

Authors:  Jérôme Yerly; Fabio Becce; Ruud B van Heeswijk; Francis R Verdun; Danilo Gubian; Reto Meuli; Matthias Stuber
Journal:  J Cardiovasc Magn Reson       Date:  2019-02-07       Impact factor: 5.364

7.  Perfusion-ventilation CT via three-material differentiation in dual-layer CT: a feasibility study.

Authors:  Andreas P Sauter; Johannes Hammel; Sebastian Ehn; Klaus Achterhold; Felix K Kopp; Melanie A Kimm; Kai Mei; Alexis Laugerette; Franz Pfeiffer; Ernst J Rummeny; Daniela Pfeiffer; Peter B Noël
Journal:  Sci Rep       Date:  2019-04-09       Impact factor: 4.379

8.  The optimal monoenergetic spectral image level of coronary computed tomography (CT) angiography on a dual-layer spectral detector CT with half-dose contrast media.

Authors:  Xin Huang; Sizhe Gao; Yue Ma; Xiaomei Lu; Zheng Jia; Yang Hou
Journal:  Quant Imaging Med Surg       Date:  2020-03

9.  Feasibility of low-dose contrast media in run-off CT angiography on dual-layer spectral detector CT.

Authors:  Haiyan Ren; Yanhua Zhen; Zheng Gong; Chuanzhuo Wang; Zhihui Chang; Jiahe Zheng
Journal:  Quant Imaging Med Surg       Date:  2021-05

10.  Impact of iodine concentration and scan parameters on image quality, contrast enhancement and radiation dose in thoracic CT.

Authors:  Marian S Solbak; Mette K Henning; Andrew England; Anne C Martinsen; Trond M Aaløkken; Safora Johansen
Journal:  Eur Radiol Exp       Date:  2020-09-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.