Literature DB >> 30506223

Can virtual monochromatic images from dual-energy CT replace low-kVp images for abdominal contrast-enhanced CT in small- and medium-sized patients?

Peijie Lv1, Zhigang Zhou1, Jie Liu1, Yaru Chai1, Huiping Zhao1, Hua Guo1, Daniele Marin2, Jianbo Gao3.   

Abstract

OBJECTIVE: To investigate the image quality and radiation dose of dual-energy computed tomography (DECT) with automatic spectral imaging protocol selection (ASIS) compared with those of low-kVp CT in abdominal multiphase CT.
METHODS: Four groups of 60 patients each underwent abdominal scans with low-kVp CT (A, 80 kVp/300 mg I/kg, body mass index [BMI] ≤ 23.9 kg/m2; C, 100 kVp/400 mg I/kg, BMI ranging from 24 to 28.9 kg/m2) or DECT with ASIS, and the 40- to 60-keV virtual monochromatic images (VMIs) generated (B and D) were matched by age, gender, BMI, cross-sectional area, and contrast agent dose; 9 patients were excluded due to technical failures. The CT number, image noise, contrast-to-noise ratio, and subjective image quality were compared between the matched protocols (A and B or C and D) on 1.25-mm reconstructed images.
RESULTS: VMIs at approximately 55 keV and 62 keV had CT numbers and contrast similar to those of 80-kVp and 100-kVp CT images, respectively. Compared to matched low-kVp images, VMIs at 50 keV provided a higher CT number and image noise and a similar or higher contrast and overall image quality. The radiation dose for DECT was higher than that of 80-kVp CT (increased by 10%), but was similar to that of 100-kVp CT.
CONCLUSION: Compared to matched low-kVp CT, VMIs at 50 keV in DECT with ASIS provided similar or higher overall image quality, with no or minimal dose penalty in small- and medium-sized patients. KEY POINTS: • Virtual monochromatic images at approximately 55 keV and 62 keV have CT numbers and contrast similar to those of 80-kVp and 100-kVp CT images, respectively, with a given noise index. • The radiation dose in dual-energy CT with automatic spectral imaging protocol selection was slightly higher than that of 80-kVp CT (increased by 10%) but was similar to that of 100-kVp CT. • Dual-energy CT may be able to replace l00-kVp CT for routine clinical abdominal contrast-enhanced CT scans.

Entities:  

Keywords:  CT protocol; Cross-sectional studies; Image processing, computer-assisted; Radiation dosage; Tomography, X-ray computed

Mesh:

Substances:

Year:  2018        PMID: 30506223     DOI: 10.1007/s00330-018-5850-z

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  36 in total

1.  Patient doses in CT examinations in Switzerland: implementation of national diagnostic reference levels.

Authors:  R Treier; A Aroua; F R Verdun; E Samara; A Stuessi; Ph R Trueb
Journal:  Radiat Prot Dosimetry       Date:  2010-10-06       Impact factor: 0.972

Review 2.  Appropriate body-mass index for Asian populations and its implications for policy and intervention strategies.

Authors: 
Journal:  Lancet       Date:  2004-01-10       Impact factor: 79.321

3.  Estimating effective dose for CT using dose-length product compared with using organ doses: consequences of adopting International Commission on Radiological Protection publication 103 or dual-energy scanning.

Authors:  Jodie A Christner; James M Kofler; Cynthia H McCollough
Journal:  AJR Am J Roentgenol       Date:  2010-04       Impact factor: 3.959

Review 4.  Multiphasic contrast-enhanced multidetector-row CT of liver: contrast-enhancement theory and practical scan protocol with a combination of fixed injection duration and patients' body-weight-tailored dose of contrast material.

Authors:  Tomoaki Ichikawa; Sukru Mehmet Erturk; Tsutomu Araki
Journal:  Eur J Radiol       Date:  2006-01-18       Impact factor: 3.528

5.  Detection of pancreatic tumors, image quality, and radiation dose during the pancreatic parenchymal phase: effect of a low-tube-voltage, high-tube-current CT technique--preliminary results.

Authors:  Daniele Marin; Rendon C Nelson; Huiman Barnhart; Sebastian T Schindera; Lisa M Ho; Tracy A Jaffe; Terry T Yoshizumi; Richard Youngblood; Ehsan Samei
Journal:  Radiology       Date:  2010-08       Impact factor: 11.105

6.  Abdominal CT with low tube voltage: preliminary observations about radiation dose, contrast enhancement, image quality, and noise.

Authors:  Yoshiharu Nakayama; Kazuo Awai; Yoshinori Funama; Masahiro Hatemura; Masanori Imuta; Takeshi Nakaura; Da Ryu; Shoji Morishita; Shamima Sultana; Natsuko Sato; Yasuyuki Yamashita
Journal:  Radiology       Date:  2005-10-19       Impact factor: 11.105

7.  Neoadjuvant chemotherapy does not increase postoperative complication rate after resection of colorectal liver metastases.

Authors:  S Yedibela; L Elad; A Wein; A Dimmler; S Merkel; W Hohenberger; T Meyer
Journal:  Eur J Surg Oncol       Date:  2005-03       Impact factor: 4.424

8.  Aortic and hepatic enhancement and tumor-to-liver contrast: analysis of the effect of different concentrations of contrast material at multi-detector row helical CT.

Authors:  Kazuo Awai; Koichi Takada; Hiromitsu Onishi; Shinichi Hori
Journal:  Radiology       Date:  2002-09       Impact factor: 11.105

9.  Hypervascular liver tumors: low tube voltage, high tube current multidetector CT during late hepatic arterial phase for detection--initial clinical experience.

Authors:  Daniele Marin; Rendon C Nelson; Ehsan Samei; Erik K Paulson; Lisa M Ho; Daniel T Boll; David M DeLong; Terry T Yoshizumi; Sebastian T Schindera
Journal:  Radiology       Date:  2009-04-03       Impact factor: 11.105

10.  Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm--initial clinical experience.

Authors:  Daniele Marin; Rendon C Nelson; Sebastian T Schindera; Samuel Richard; Richard S Youngblood; Terry T Yoshizumi; Ehsan Samei
Journal:  Radiology       Date:  2010-01       Impact factor: 11.105

View more
  5 in total

Review 1.  Updates on Imaging of Liver Tumors.

Authors:  Arya Haj-Mirzaian; Ana Kadivar; Ihab R Kamel; Atif Zaheer
Journal:  Curr Oncol Rep       Date:  2020-04-16       Impact factor: 5.075

2.  In vivo quantification of bone mineral density of lumbar vertebrae using fast kVp switching dual-energy CT: correlation with quantitative computed tomography.

Authors:  Shuwei Zhou; Lu Zhu; Tian You; Ping Li; Hongrong Shen; Yewen He; Hui Gao; Luyou Yan; Zhuo He; Ying Guo; Yaxi Zhang; Kun Zhang
Journal:  Quant Imaging Med Surg       Date:  2021-01

3.  CTPA with a conventional CT at 100 kVp vs. a spectral-detector CT at 120 kVp: Comparison of radiation exposure, diagnostic performance and image quality.

Authors:  Andreas P Sauter; Nadav Shapira; Felix K Kopp; Juliane Aichele; Jannis Bodden; Andreas Knipfer; Ernst J Rummeny; Peter B Noël
Journal:  Eur J Radiol Open       Date:  2020-05-07

Review 4.  Computed Tomography Techniques, Protocols, Advancements, and Future Directions in Liver Diseases.

Authors:  Naveen M Kulkarni; Alice Fung; Avinash R Kambadakone; Benjamin M Yeh
Journal:  Magn Reson Imaging Clin N Am       Date:  2021-08       Impact factor: 1.376

5.  An Individualized Contrast-Enhanced Liver Computed Tomography Imaging Protocol Based on Body Mass Index in 126 Patients Seen for Liver Cirrhosis.

Authors:  Jian Jiang; Maowei Zhang; Yuan Ji; Chunfeng Li; Xin Fang; Shuyuan Zhang; Wei Wang; Lijun Wang; Ailian Liu
Journal:  Med Sci Monit       Date:  2021-06-24
  5 in total