Literature DB >> 12202710

Aortic and hepatic enhancement and tumor-to-liver contrast: analysis of the effect of different concentrations of contrast material at multi-detector row helical CT.

Kazuo Awai1, Koichi Takada, Hiromitsu Onishi, Shinichi Hori.   

Abstract

PURPOSE: To investigate the effect of different iodine concentrations of contrast material on aortic and hepatic enhancement and the detectability of hypervascular hepatocellular carcinoma (HCC) with multi-detector row computed tomography (CT) and a uniphasic contrast material injection technique.
MATERIALS AND METHODS: Two hundred one patients with known or who were suspected of having HCC underwent multi-detector row CT; 58 patients with hypervascular HCC were identified. First-, second-, and third-phase scanning was started with the aortic arrival times plus 15 seconds, plus 30 seconds, and plus 105 seconds, respectively. All patients were assigned randomly into two groups. Patients in groups A and B received iopamidol with an iodine concentration of 300 mg/mL and 370 mg/mL, respectively, with the same total iodine load per patient per body weight. The liver and aorta enhancement and tumor-to-liver contrast (TLC) were measured. Depiction of hepatic arteries was evaluated visually by two radiologists.
RESULTS: During the first phase, aortic enhancement was significantly (P <.01) higher in group B, with no significant difference in hepatic enhancement between the two groups. During the second phase, aortic enhancement was significantly (P <.01) higher in group A, with no significant difference in hepatic enhancement. The TLC was significantly (P <.01) higher in group B during the first phase, but there was no significant difference between the two groups during the second phase. There was no significant difference in any parameters between the two groups during the third phase. Depiction of the hepatic arteries in group B was significantly (P <.05) superior to that in group A.
CONCLUSION: In the arterial phase, administration of a higher concentration of contrast material is effective for a significantly higher TLC. Copyright RSNA, 2002

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12202710     DOI: 10.1148/radiol.2243011188

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  42 in total

1.  Comparison of two contrast materials with different iodine concentrations in enhancing the density of the the aorta, portal vein and liver at multi-detector row CT: a randomized study.

Authors:  Hiromasa Suzuki; Hidekazu Oshima; Norio Shiraki; Chisa Ikeya; Yuta Shibamoto
Journal:  Eur Radiol       Date:  2004-08-12       Impact factor: 5.315

Review 2.  Use of high-concentration contrast media in multiple-detector-row CT: principles and rationale.

Authors:  Dominik Fleischmann
Journal:  Eur Radiol       Date:  2003-12       Impact factor: 5.315

Review 3.  MDCT of benign liver tumors and metastases.

Authors:  Pierre-Jean Valette; Frank Pilleul; Arielle Crombé-Ternamian
Journal:  Eur Radiol       Date:  2003-12       Impact factor: 5.315

Review 4.  Optimizing technique for multi-slice CT.

Authors:  Sanjay Saini; Roy V Dsouza
Journal:  Eur Radiol       Date:  2003-12       Impact factor: 5.315

Review 5.  MDCT of primary liver malignancies.

Authors:  Alfonso Marchianò
Journal:  Eur Radiol       Date:  2003-12       Impact factor: 5.315

6.  Multiphase contrast-enhanced CT with highly concentrated contrast agent can be used for PET attenuation correction in integrated PET/CT imaging.

Authors:  Philip Aschoff; Christian Plathow; Thomas Beyer; Matthias P Lichy; Gunter Erb; Mehmet Ö Öksüz; Claus D Claussen; Christina Pfannenberg
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-11-29       Impact factor: 9.236

7.  Reduction of the unnecessary dose from the over-range area with a spiral dynamic z-collimator: comparison of beam pitch and detector coverage with 128-detector row CT.

Authors:  Takashi Shirasaka; Yoshinori Funama; Mutsukazu Hayashi; Shinichi Awamoto; Masatoshi Kondo; Yasuhiko Nakamura; Masamitsu Hatakenaka; Hiroshi Honda
Journal:  Radiol Phys Technol       Date:  2011-10-15

8.  Optimizing scan timing of hepatic arterial phase by physiologic pharmacokinetic analysis in bolus-tracking technique by multi-detector row computed tomography.

Authors:  Isao Yamaguchi; Eiji Kidoya; Masayuki Suzuki; Hirohiko Kimura
Journal:  Radiol Phys Technol       Date:  2010-09-25

9.  Evaluation of a method for improving the detection of hepatocellular carcinoma.

Authors:  Edgar Bendik; Peter B Noël; Daniela Münzel; Alexander A Fingerle; Martin Henninger; Christian Markus; Alain Vlassenbroek; Ernst J Rummeny; Martin Dobritz
Journal:  Eur Radiol       Date:  2013-09-03       Impact factor: 5.315

10.  [Multidetector computed tomography of the liver].

Authors:  W Schima; C Kulinna; A Ba-Ssalamah; T Grünberger
Journal:  Radiologe       Date:  2005-01       Impact factor: 0.635

View more