Literature DB >> 27052204

Accelerating fully phase-encoded MRI near metal using multiband radiofrequency excitation.

Nathan S Artz1,2, Curtis N Wiens1, Matthew R Smith1, Diego Hernando1, Alexey Samsonov1, Scott B Reeder1,3,4,5,6.   

Abstract

PURPOSE: To develop a multiband radiofrequency (RF) excitation strategy for simultaneous excitation of multiple RF offsets to accelerate fully phase-encoded imaging near metallic prostheses.
METHODS: Multiband RF excitation was designed and incorporated into a spectrally resolved fully phase-encoded (SR-FPE) imaging scheme. A triband (-6, 0, 6 kHz) acquisition was compared with three separate single-band acquisitions at the corresponding RF offsets with a phantom containing the head of a hip prosthesis. In vivo multiband data with continuous spectral coverage were acquired in the knee of a healthy volunteer with the head of a hip prosthesis placed posteriorly and in a volunteer with a total knee prosthetic implant.
RESULTS: Phantom images acquired with triband excitation were essentially identical to the composite of three single-band excitations, but with an acceleration factor of three. In vivo multiband images of the healthy knee with adjacent metal demonstrated very good depiction of knee anatomy. In vivo images of the total knee replacement were successfully acquired, allowing visualization of native tissue with far less signal dropout than 2D-FSE.
CONCLUSIONS: FPE imaging with multiband excitation is feasible in the presence of extreme off-resonance. This approach can reduce scan time and/or increase off-resonance coverage, enabling in vivo FPE imaging near metallic prostheses over a broad off-resonance spectrum. Magn Reson Med 77:1223-1230, 2017.
© 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  fully phase-encoded; imaging near metal; magnetic resonance imaging; metallic prostheses; multiband radiofrequency excitation; spectrally resolved

Mesh:

Substances:

Year:  2016        PMID: 27052204      PMCID: PMC5537622          DOI: 10.1002/mrm.26209

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  31 in total

1.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

2.  Imaging near metal with a MAVRIC-SEMAC hybrid.

Authors:  K M Koch; A C Brau; W Chen; G E Gold; B A Hargreaves; M Koff; G C McKinnon; H G Potter; K F King
Journal:  Magn Reson Med       Date:  2011-01       Impact factor: 4.668

Review 3.  Magnetic resonance imaging near metal implants.

Authors:  K M Koch; B A Hargreaves; K Butts Pauly; W Chen; G E Gold; K F King
Journal:  J Magn Reson Imaging       Date:  2010-10       Impact factor: 4.813

4.  Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) for multi-slice imaging.

Authors:  Felix A Breuer; Martin Blaimer; Robin M Heidemann; Matthias F Mueller; Mark A Griswold; Peter M Jakob
Journal:  Magn Reson Med       Date:  2005-03       Impact factor: 4.668

5.  Fast spin echo sequences with very long echo trains: design of variable refocusing flip angle schedules and generation of clinical T2 contrast.

Authors:  Reed F Busse; Hari Hariharan; Anthony Vu; Jean H Brittain
Journal:  Magn Reson Med       Date:  2006-05       Impact factor: 4.668

6.  Geometrically undistorted MRI in the presence of field inhomogeneities using compressed sensing accelerated broadband 3D phase encoded turbo spin-echo imaging.

Authors:  Jetse S van Gorp; Chris J G Bakker; Job G Bouwman; Jouke Smink; Frank Zijlstra; Peter R Seevinck
Journal:  Phys Med Biol       Date:  2014-12-30       Impact factor: 3.609

7.  Off-resonance suppression for multispectral MR imaging near metallic implants.

Authors:  J Chiel den Harder; Gert H van Yperen; Ulrike A Blume; Clemens Bos
Journal:  Magn Reson Med       Date:  2014-01-31       Impact factor: 4.668

8.  Accelerating sequences in the presence of metal by exploiting the spatial distribution of off-resonance.

Authors:  Matthew R Smith; Nathan S Artz; Kevin M Koch; Alexey Samsonov; Scott B Reeder
Journal:  Magn Reson Med       Date:  2014-01-15       Impact factor: 4.668

9.  Characterizing the limits of MRI near metallic prostheses.

Authors:  Matthew R Smith; Nathan S Artz; Curtis Wiens; Diego Hernando; Scott B Reeder
Journal:  Magn Reson Med       Date:  2014-12-05       Impact factor: 4.668

10.  SEMAC: Slice Encoding for Metal Artifact Correction in MRI.

Authors:  Wenmiao Lu; Kim Butts Pauly; Garry E Gold; John M Pauly; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2009-07       Impact factor: 4.668

View more
  2 in total

1.  Externally calibrated parallel imaging for 3D multispectral imaging near metallic implants using broadband ultrashort echo time imaging.

Authors:  Curtis N Wiens; Nathan S Artz; Hyungseok Jang; Alan B McMillan; Scott B Reeder
Journal:  Magn Reson Med       Date:  2016-07-12       Impact factor: 4.668

2.  Fully phase-encoded MRI near metallic implants using ultrashort echo times and broadband excitation.

Authors:  Curtis N Wiens; Nathan S Artz; Hyungseok Jang; Alan B McMillan; Kevin M Koch; Scott B Reeder
Journal:  Magn Reson Med       Date:  2017-08-21       Impact factor: 4.668

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.