Geometrically undistorted MRI in the presence of field inhomogeneities using compressed sensing accelerated broadband 3D phase encoded turbo spin-echo imaging.

Jetse S van Gorp1, Chris J G Bakker, Job G Bouwman, Jouke Smink, Frank Zijlstra, Peter R Seevinck.   

Abstract

In this study, we explore the potential of compressed sensing (CS) accelerated broadband 3D phase-encoded turbo spin-echo (3D-PE-TSE) for the purpose of geometrically undistorted imaging in the presence of field inhomogeneities. To achieve this goal 3D-PE-SE and 3D-PE-TSE sequences with broadband rf pulses and dedicated undersampling patterns were implemented on a clinical scanner. Additionally, a 3D multi-spectral spin-echo (ms3D-SE) sequence was implemented for reference purposes. First, we demonstrated the influence of susceptibility induced off-resonance effects on the spatial encoding of broadband 3D-SE, ms3D-SE, 3D-PE-SE and 3D-PE-TSE using a grid phantom containing a titanium implant (Δχ = 182 ppm) with x-ray CT as a gold standard. These experiments showed that the spatial encoding of 3D-PE-(T)SE was unaffected by susceptibility induced off-resonance effects, which caused geometrical distortions and/or signal hyper-intensities in broadband 3D-SE and, to a lesser extent, in ms3D-SE frequency encoded methods. Additionally, an SNR analysis was performed and the temporally resolved signal of 3D-PE-(T)SE sequences was exploited to retrospectively decrease the acquisition bandwidth and obtain field offset maps. The feasibility of CS acceleration was studied retrospectively and prospectively for the 3D-PE-SE sequence using an existing CS algorithm adapted for the reconstruction of 3D data with undersampling in all three phase encoded dimensions. CS was combined with turbo-acceleration by variable density undersampling and spherical stepwise T2 weighting by randomly sorting consecutive echoes in predefined spherical k-space layers. The CS-TSE combination resulted in an overall acceleration factor of 60, decreasing the original 3D-PE-SE scan time from 7 h to 7 min. Finally, CS accelerated 3D-PE-TSE in vivo images of a titanium screw were obtained within 10 min using a micro-coil demonstrating the feasibility of geometrically undistorted MRI near severe field inhomogeneities.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25548990     DOI: 10.1088/0031-9155/60/2/615

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Accelerating fully phase-encoded MRI near metal using multiband radiofrequency excitation.

Authors:  Nathan S Artz; Curtis N Wiens; Matthew R Smith; Diego Hernando; Alexey Samsonov; Scott B Reeder
Journal:  Magn Reson Med       Date:  2016-03-28       Impact factor: 4.668

2.  Externally calibrated parallel imaging for 3D multispectral imaging near metallic implants using broadband ultrashort echo time imaging.

Authors:  Curtis N Wiens; Nathan S Artz; Hyungseok Jang; Alan B McMillan; Scott B Reeder
Journal:  Magn Reson Med       Date:  2016-07-12       Impact factor: 4.668

3.  Fully phase-encoded MRI near metallic implants using ultrashort echo times and broadband excitation.

Authors:  Curtis N Wiens; Nathan S Artz; Hyungseok Jang; Alan B McMillan; Kevin M Koch; Scott B Reeder
Journal:  Magn Reson Med       Date:  2017-08-21       Impact factor: 4.668

Review 4.  Sparse Reconstruction Techniques in Magnetic Resonance Imaging: Methods, Applications, and Challenges to Clinical Adoption.

Authors:  Alice C Yang; Madison Kretzler; Sonja Sudarski; Vikas Gulani; Nicole Seiberlich
Journal:  Invest Radiol       Date:  2016-06       Impact factor: 6.016

5.  Single shot three-dimensional pulse sequence for hyperpolarized 13 C MRI.

Authors:  Jiazheng Wang; Alan J Wright; De-En Hu; Richard Hesketh; Kevin M Brindle
Journal:  Magn Reson Med       Date:  2016-02-24       Impact factor: 4.668

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.