Literature DB >> 26643024

Positron Emission Tomography: Current Challenges and Opportunities for Technological Advances in Clinical and Preclinical Imaging Systems.

Juan José Vaquero1, Paul Kinahan2.   

Abstract

Positron emission tomography (PET) imaging is based on detecting two time-coincident high-energy photons from the emission of a positron-emitting radioisotope. The physics of the emission, and the detection of the coincident photons, give PET imaging unique capabilities for both very high sensitivity and accurate estimation of the in vivo concentration of the radiotracer. PET imaging has been widely adopted as an important clinical modality for oncological, cardiovascular, and neurological applications. PET imaging has also become an important tool in preclinical studies, particularly for investigating murine models of disease and other small-animal models. However, there are several challenges to using PET imaging systems. These include the fundamental trade-offs between resolution and noise, the quantitative accuracy of the measurements, and integration with X-ray computed tomography and magnetic resonance imaging. In this article, we review how researchers and industry are addressing these challenges.

Entities:  

Keywords:  PET/CT; PET/MRI; multimodality kinetic modeling; silicon photomultipliers; system model; tomographic image reconstruction

Mesh:

Year:  2015        PMID: 26643024      PMCID: PMC5299095          DOI: 10.1146/annurev-bioeng-071114-040723

Source DB:  PubMed          Journal:  Annu Rev Biomed Eng        ISSN: 1523-9829            Impact factor:   9.590


  92 in total

Review 1.  Integrated PET/MR.

Authors:  Harald H Quick
Journal:  J Magn Reson Imaging       Date:  2013-12-12       Impact factor: 4.813

2.  Dual-energy (spectral) CT: applications in abdominal imaging.

Authors:  Alvin C Silva; Brian G Morse; Amy K Hara; Robert G Paden; Norio Hongo; William Pavlicek
Journal:  Radiographics       Date:  2011 Jul-Aug       Impact factor: 5.333

3.  MR-Based PET attenuation correction for PET/MR imaging.

Authors:  Ilja Bezrukov; Frédéric Mantlik; Holger Schmidt; Bernhard Schölkopf; Bernd J Pichler
Journal:  Semin Nucl Med       Date:  2013-01       Impact factor: 4.446

Review 4.  Quantitative assessment of dynamic PET imaging data in cancer imaging.

Authors:  Mark Muzi; Finbarr O'Sullivan; David A Mankoff; Robert K Doot; Larry A Pierce; Brenda F Kurland; Hannah M Linden; Paul E Kinahan
Journal:  Magn Reson Imaging       Date:  2012-07-21       Impact factor: 2.546

5.  Multiplexing strategies for monolithic crystal PET detector modules.

Authors:  L A Pierce; W C J Hunter; D R Haynor; L R MacDonald; P E Kinahan; R S Miyaoka
Journal:  Phys Med Biol       Date:  2014-08-22       Impact factor: 3.609

Review 6.  Instrumentation aspects of animal PET.

Authors:  Yuan-Chuan Tai; Richard Laforest
Journal:  Annu Rev Biomed Eng       Date:  2005       Impact factor: 9.590

7.  Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype.

Authors:  Ciprian Catana; Andre van der Kouwe; Thomas Benner; Christian J Michel; Michael Hamm; Matthias Fenchel; Bruce Fischl; Bruce Rosen; Matthias Schmand; A Gregory Sorensen
Journal:  J Nucl Med       Date:  2010-09       Impact factor: 10.057

8.  Single-scan dual-tracer FLT+FDG PET tumor characterization.

Authors:  Dan J Kadrmas; Thomas C Rust; John M Hoffman
Journal:  Phys Med Biol       Date:  2013-01-08       Impact factor: 3.609

9.  Performance measurements of the Siemens mMR integrated whole-body PET/MR scanner.

Authors:  Gaspar Delso; Sebastian Fürst; Björn Jakoby; Ralf Ladebeck; Carl Ganter; Stephan G Nekolla; Markus Schwaiger; Sibylle I Ziegler
Journal:  J Nucl Med       Date:  2011-11-11       Impact factor: 10.057

10.  Optimal whole-body PET scanner configurations for different volumes of LSO scintillator: a simulation study.

Authors:  Jonathan K Poon; Magnus L Dahlbom; William W Moses; Karthik Balakrishnan; Wenli Wang; Simon R Cherry; Ramsey D Badawi
Journal:  Phys Med Biol       Date:  2012-06-07       Impact factor: 3.609

View more
  45 in total

Review 1.  The Importance of Time-of-Flight Reconstruction and Point Spread Modeling in the Measurement of Myocardial Blood Flow Parameters.

Authors:  James A Case
Journal:  Curr Cardiol Rep       Date:  2021-06-03       Impact factor: 2.931

2.  In Vivo Imaging With Confirmation by Histopathology for Increased Rigor and Reproducibility in Translational Research: A Review of Examples, Options, and Resources.

Authors:  Kathleen Gabrielson; Robert Maronpot; Sébastien Monette; Coraline Mlynarczyk; Yuval Ramot; Abraham Nyska; Polina Sysa-Shah
Journal:  ILAR J       Date:  2018-12-01

Review 3.  Multiplex bioimaging of single-cell spatial profiles for precision cancer diagnostics and therapeutics.

Authors:  Mayar Allam; Shuangyi Cai; Ahmet F Coskun
Journal:  NPJ Precis Oncol       Date:  2020-05-01

Review 4.  History and future technical innovation in positron emission tomography.

Authors:  Terry Jones; David Townsend
Journal:  J Med Imaging (Bellingham)       Date:  2017-03-31

Review 5.  Characterization of PET/CT images using texture analysis: the past, the present… any future?

Authors:  Mathieu Hatt; Florent Tixier; Larry Pierce; Paul E Kinahan; Catherine Cheze Le Rest; Dimitris Visvikis
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-06-06       Impact factor: 9.236

Review 6.  High-Definition Medicine.

Authors:  Ali Torkamani; Kristian G Andersen; Steven R Steinhubl; Eric J Topol
Journal:  Cell       Date:  2017-08-24       Impact factor: 41.582

Review 7.  Imaging of intranasal drug delivery to the brain.

Authors:  Michael C Veronesi; Mosa Alhamami; Shelby B Miedema; Yeonhee Yun; Miguel Ruiz-Cardozo; Michael W Vannier
Journal:  Am J Nucl Med Mol Imaging       Date:  2020-02-25

Review 8.  Tactics for preclinical validation of receptor-binding radiotracers.

Authors:  Susan Z Lever; Kuo-Hsien Fan; John R Lever
Journal:  Nucl Med Biol       Date:  2016-09-03       Impact factor: 2.408

9.  Detection Threshold and Reproducibility of 68Ga-PSMA11 PET/CT in a Mouse Model of Prostate Cancer.

Authors:  Katharina Lückerath; Andreea D Stuparu; Liu Wei; Woosuk Kim; Caius G Radu; Christine E Mona; Jeremie Calais; Matthew Rettig; Robert E Reiter; Johannes Czernin; Roger Slavik; Ken Herrmann; Matthias Eiber; Wolfgang P Fendler
Journal:  J Nucl Med       Date:  2018-03-30       Impact factor: 10.057

10.  An EEG-fNIRS hybridization technique in the four-class classification of alzheimer's disease.

Authors:  Pietro A Cicalese; Rihui Li; Mohammad B Ahmadi; Chushan Wang; Joseph T Francis; Sudhakar Selvaraj; Paul E Schulz; Yingchun Zhang
Journal:  J Neurosci Methods       Date:  2020-02-08       Impact factor: 2.390

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.