Literature DB >> 25146849

Multiplexing strategies for monolithic crystal PET detector modules.

L A Pierce1, W C J Hunter, D R Haynor, L R MacDonald, P E Kinahan, R S Miyaoka.   

Abstract

To reduce the number of output channels and associated cost in PET detectors, strategies to multiplex the signal channels have been investigated by several researchers. This work aims to find an optimal multiplexing strategy for detector modules consisting of a monolithic LYSO scintillator coupled to a 64-channel PMT. We apply simulated multiplexing strategies to measured data from two continuous miniature crystal element (cMiCE) detector modules. The strategies tested include standard methods such as row column summation and its variants, as well as new data-driven methods involving the principal components of measured data and variants of those components. The detector positioning resolution and bias are measured for each multiplexing strategy and the results are compared. The mean FWHM over the entire detector was 1.23 mm for no multiplexing (64 channels). Using 16 principal component channels yielded a mean FWHM resolution of 1.21 mm, while traditional row/column summation (16 channels) yielded 1.28 mm. Using 8 principal component output channels resulted in a resolution of 1.30 mm. Using the principal components of the calibration data to guide the multiplexing scheme appears to be a viable method for reducing the number of output data channels. Further study is needed to determine if the depth-of-interaction resolution can be preserved with this multiplexing scheme.

Entities:  

Mesh:

Year:  2014        PMID: 25146849      PMCID: PMC4157903          DOI: 10.1088/0031-9155/59/18/5347

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  12 in total

1.  An 8×8 Row-Column Summing Readout Electronics for Preclinical Positron Emission Tomography Scanners.

Authors:  Y C Shih; F W Sun; L R Macdonald; B P Otis; R S Miyaoka; W McDougald; T K Lewellen
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2009-10-24

2.  Depth of interaction decoding of a continuous crystal detector module.

Authors:  T Ling; T K Lewellen; R S Miyaoka
Journal:  Phys Med Biol       Date:  2007-03-29       Impact factor: 3.609

3.  A novel, SiPM-array-based, monolithic scintillator detector for PET.

Authors:  Dennis R Schaart; Herman T van Dam; Stefan Seifert; Ruud Vinke; Peter Dendooven; Herbert Löhner; Freek J Beekman
Journal:  Phys Med Biol       Date:  2009-05-15       Impact factor: 3.609

4.  Effect of Number of Readout Channels on the Intrinsic Spatial Resolution Performance of a Continuous Miniature Crystal Element (cMiCE) Detector.

Authors:  Robert S Miyaoka; Tao Ling; Tom K Lewellen
Journal:  IEEE Trans Nucl Sci       Date:  2007-10       Impact factor: 1.679

5.  Monolithic scintillator PET detectors with intrinsic depth-of-interaction correction.

Authors:  Marnix C Maas; Dennis R Schaart; D J Jan van der Laan; Peter Bruyndonckx; Cedric Lemaître; Freek J Beekman; Carel W E van Eijk
Journal:  Phys Med Biol       Date:  2009-03-05       Impact factor: 3.609

6.  A high resolution, monolithic crystal, PET/MRI detector with DOI positioning capability.

Authors:  Xiaoli Li; Cate Lockhart; Tom K Lewellen; Robert S Miyaoka
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2008

7.  Parametric positioning of a continuous crystal PET detector with depth of interaction decoding.

Authors:  T Ling; T H Burnett; T K Lewellen; R S Miyaoka
Journal:  Phys Med Biol       Date:  2008-03-10       Impact factor: 3.609

8.  Scintillation cameras based on new position arithmetics.

Authors:  E Tanaka; T Hiramoto; N Nohara
Journal:  J Nucl Med       Date:  1970-09       Impact factor: 10.057

9.  Study of PET Detector Performance with Varying SiPM Parameters and Readout Schemes.

Authors:  Xiaoli Li; Cate Lockhart; Tom K Lewellen; Robert S Miyaoka
Journal:  IEEE Trans Nucl Sci       Date:  2011       Impact factor: 1.679

10.  Investigation of analog charge multiplexing schemes for SiPM based PET block detectors.

Authors:  Evan Downie; Xin Yang; Hao Peng
Journal:  Phys Med Biol       Date:  2013-05-16       Impact factor: 3.609

View more
  4 in total

1.  Modularized compact positron emission tomography detector for rapid system development.

Authors:  Daoming Xi; Xiang Liu; Chen Zeng; Wei Liu; Yanzhao Li; Yuexuan Hua; Xiongze Mei; Heejong Kim; Peng Xiao; Chien-Min Kao; Qingguo Xie
Journal:  J Med Imaging (Bellingham)       Date:  2016-12-20

2.  Simulation study of quantitative precision of the PET/X dedicated breast PET scanner.

Authors:  Chengeng Zeng; Paul E Kinahan; Hua Qian; Robert L Harrison; Kyle M Champley; Lawrence R MacDonald
Journal:  J Med Imaging (Bellingham)       Date:  2017-10-30

3.  Characterization of highly multiplexed monolithic PET / gamma camera detector modules.

Authors:  L A Pierce; S Pedemonte; D DeWitt; L MacDonald; W C J Hunter; K Van Leemput; R Miyaoka
Journal:  Phys Med Biol       Date:  2018-03-29       Impact factor: 3.609

Review 4.  Positron Emission Tomography: Current Challenges and Opportunities for Technological Advances in Clinical and Preclinical Imaging Systems.

Authors:  Juan José Vaquero; Paul Kinahan
Journal:  Annu Rev Biomed Eng       Date:  2015       Impact factor: 9.590

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.