Literature DB >> 28401173

History and future technical innovation in positron emission tomography.

Terry Jones1, David Townsend2.   

Abstract

Instrumentation for positron emission tomography (PET) imaging has experienced tremendous improvements in performance over the past 60 years since it was first conceived as a medical imaging modality. Spatial resolution has improved by a factor of 10 and sensitivity by a factor of 40 from the early designs in the 1970s to the high-performance scanners of today. Multimodality configurations have emerged that combine PET with computed tomography (CT) and, more recently, with MR. Whole-body scans for clinical purposes can now be acquired in under 10 min on a state-of-the-art PET/CT. This paper will review the history of these technical developments over 40 years and summarize the important clinical research and healthcare applications that have been made possible by these technical advances. Some perspectives for the future of this technology will also be presented that promise to bring about new applications of this imaging modality in clinical research and healthcare.

Keywords:  PET instrumentation; PET/CT; PET/MR; clinical applications; microPET; positron emission tomography

Year:  2017        PMID: 28401173      PMCID: PMC5374360          DOI: 10.1117/1.JMI.4.1.011013

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  100 in total

1.  A positron-emission transaxial tomograph for nuclear imaging (PETT).

Authors:  M M Ter-Pogossian; M E Phelps; E J Hoffman; N A Mullani
Journal:  Radiology       Date:  1975-01       Impact factor: 11.105

2.  Physical characteristics of the ECAT EXACT3D positron tomograph.

Authors:  T J Spinks; T Jones; P M Bloomfield; D L Bailey; M Miller; D Hogg; W F Jones; K Vaigneur; J Reed; J Young; D Newport; C Moyers; M E Casey; R Nutt
Journal:  Phys Med Biol       Date:  2000-09       Impact factor: 3.609

3.  Application of annihilation coincidence detection to transaxial reconstruction tomography.

Authors:  M E Phelps; E J Hoffman; N A Mullani; M M Ter-Pogossian
Journal:  J Nucl Med       Date:  1975-03       Impact factor: 10.057

4.  Design and performance characteristics of a whole-body positron transaxial tomograph.

Authors:  E J Hoffmann; M E Phelps; N A Mullani; C S Higgins; M M Ter-Pogossian
Journal:  J Nucl Med       Date:  1976-06       Impact factor: 10.057

5.  A comparison of 82Rb+ and 13NH3 for myocardial positron scintigraphy.

Authors:  T F Budinger; Y Yano; B Hoop
Journal:  J Nucl Med       Date:  1975-05       Impact factor: 10.057

6.  Comparison of 3-D reconstruction with 3D-OSEM and with FORE+OSEM for PET.

Authors:  X Liu; C Comtat; C Michel; P Kinahan; M Defrise; D Townsend
Journal:  IEEE Trans Med Imaging       Date:  2001-08       Impact factor: 10.048

7.  Tomographic measurement of local cerebral glucose metabolic rate in humans with (F-18)2-fluoro-2-deoxy-D-glucose: validation of method.

Authors:  M E Phelps; S C Huang; E J Hoffman; C Selin; L Sokoloff; D E Kuhl
Journal:  Ann Neurol       Date:  1979-11       Impact factor: 10.422

8.  Results of preliminary clinical trials of the positron emission mammography system PEM-I: a dedicated breast imaging system producing glucose metabolic images using FDG.

Authors:  K Murthy; M Aznar; C J Thompson; A Loutfi; R Lisbona; J H Gagnon
Journal:  J Nucl Med       Date:  2000-11       Impact factor: 10.057

9.  A combined PET/CT scanner for clinical oncology.

Authors:  T Beyer; D W Townsend; T Brun; P E Kinahan; M Charron; R Roddy; J Jerin; J Young; L Byars; R Nutt
Journal:  J Nucl Med       Date:  2000-08       Impact factor: 10.057

10.  HUMAN BONE MARROW DISTRIBUTION SHOWN IN VIVO BY IRON-52 AND THE POSITRON SCINTILLATION CAMERA.

Authors:  H O ANGER; D C VANDYKE
Journal:  Science       Date:  1964-06-26       Impact factor: 47.728

View more
  32 in total

Review 1.  Innovations in Instrumentation for Positron Emission Tomography.

Authors:  Eric Berg; Simon R Cherry
Journal:  Semin Nucl Med       Date:  2018-03-12       Impact factor: 4.446

2.  A Comparison of 18F-FDG-PET/MRI and 18F-FDG-PET/CT in the Cancer Staging of Locoregional Lymph Nodes.

Authors:  David Slouka; Jiri Krcal; Tomas Kostlivy; Petr Hrabacka; Alena Skalova; Hynek Mirka; Ondrej Topolcan; Radek Kucera
Journal:  In Vivo       Date:  2020 Jul-Aug       Impact factor: 2.155

3.  Development of Dedicated Brain PET Imaging Devices: Recent Advances and Future Perspectives.

Authors:  Ciprian Catana
Journal:  J Nucl Med       Date:  2019-04-26       Impact factor: 10.057

Review 4.  Imaging of intranasal drug delivery to the brain.

Authors:  Michael C Veronesi; Mosa Alhamami; Shelby B Miedema; Yeonhee Yun; Miguel Ruiz-Cardozo; Michael W Vannier
Journal:  Am J Nucl Med Mol Imaging       Date:  2020-02-25

5.  Quantitative Whole-Body Imaging of I-124-Labeled Adeno-Associated Viral Vector Biodistribution in Nonhuman Primates.

Authors:  Douglas J Ballon; Jonathan B Rosenberg; Edward K Fung; Anastasia Nikolopoulou; Paresh Kothari; Bishnu P De; Bin He; Alvin Chen; Linda A Heier; Dolan Sondhi; Stephen M Kaminsky; Paul David Mozley; John W Babich; Ronald G Crystal
Journal:  Hum Gene Ther       Date:  2020-12       Impact factor: 5.695

Review 6.  Single and Combined Neuroimaging Techniques for Alzheimer's Disease Detection.

Authors:  Morteza Amini; Mir Mohsen Pedram; Alireza Moradi; Mahdieh Jamshidi; Mahshad Ouchani
Journal:  Comput Intell Neurosci       Date:  2021-07-13

Review 7.  What scans we will read: imaging instrumentation trends in clinical oncology.

Authors:  Thomas Beyer; Luc Bidaut; John Dickson; Marc Kachelriess; Fabian Kiessling; Rainer Leitgeb; Jingfei Ma; Lalith Kumar Shiyam Sundar; Benjamin Theek; Osama Mawlawi
Journal:  Cancer Imaging       Date:  2020-06-09       Impact factor: 3.909

8.  H2RSPET: a 0.5 mm resolution high-sensitivity small-animal PET scanner, a simulation study.

Authors:  Youfang Lai; Qian Wang; Shiwei Zhou; Zhaoheng Xie; Jinyi Qi; Simon R Cherry; Mingwu Jin; Yujie Chi; Junwei Du
Journal:  Phys Med Biol       Date:  2021-03-09       Impact factor: 3.609

9.  Resting-state brain metabolic fingerprinting clusters (biomarkers) and predictive models for major depression in multiple myeloma patients.

Authors:  Xiaofei Wang; Joshua Eichhorn; Iqbal Haq; Ahmad Baghal
Journal:  PLoS One       Date:  2021-05-06       Impact factor: 3.240

Review 10.  Synergistic motion compensation strategies for positron emission tomography when acquired simultaneously with magnetic resonance imaging.

Authors:  Irene Polycarpou; Georgios Soultanidis; Charalampos Tsoumpas
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2021-07-05       Impact factor: 4.226

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.