Literature DB >> 26560726

Third-generation dual-source CT of the neck using automated tube voltage adaptation in combination with advanced modeled iterative reconstruction: evaluation of image quality and radiation dose.

Jan-Erik Scholtz1, Julian L Wichmann2,3, Kristina Hüsers2,3, Moritz H Albrecht2,3, Martin Beeres2,3, Ralf W Bauer2,3, Thomas J Vogl2,3, Boris Bodelle2,3.   

Abstract

PURPOSE: To evaluate image quality and radiation dose in third-generation dual-source computed tomography (DSCT) of the neck using automated tube voltage adaptation (TVA) with advanced modelled iterative reconstruction (ADMIRE) algorithm.
METHODS: One hundred and sixteen patients were retrospectively evaluated. Group A (n = 59) was examined on second-generation DSCT with automated TVA and filtered back projection. Group B (n = 57) was examined on a third-generation DSCT with automated TVA and ADMIRE. Age, body diameter, attenuation of several anatomic structures, noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), radiation dose (CTDIvol) and size-specific dose estimates (SSDE) were assessed. Diagnostic acceptability was rated by three readers.
RESULTS: Age (p = 0.87) and body diameter (p = 0.075) did not differ significantly. Tube voltage in Group A was set automatically to 100 kV for all patients (n = 59), and to 70 kV (n = 2), 80 kV (n = 5), and 90 kV (n = 50) in Group B. Noise was reduced and CNR was increased significantly (p < 0.001). Diagnostic acceptability was rated high in both groups, with better ratings in Group B (p < 0.001). SSDE was reduced by 34 % in Group B (20.38 ± 1.63 mGy vs. 13.04 ± 1.50 mGy, p < 0.001).
CONCLUSION: Combination of automated TVA and ADMIRE in neck CT using third-generation DSCT results in a substantial radiation dose reduction with low noise and increased CNR. KEY POINTS: • Third-generation DSCT provides automated tube voltage adaptation with an increment of 10 kV. • 10 kV increment optimizes scans to the patient's neck anatomy. • TVA combined with ADMIRE significantly lower radiation dose in contrast-enhanced neck CT. • TVA in combination with ADMIRE reduces noise and increases SNR and CNR. • Image analysis quoted less noise and better diagnostic acceptability in third-generation DSCT.

Entities:  

Keywords:  ADMIRE; Automated tube voltage adaptation; Iterative reconstruction; Neck; Third-generation dual-source CT

Mesh:

Year:  2015        PMID: 26560726     DOI: 10.1007/s00330-015-4099-z

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  29 in total

1.  Low kilovoltage CT of the neck with 70 kVp: comparison with a standard protocol.

Authors:  R Gnannt; A Winklehner; R Goetti; B Schmidt; S Kollias; H Alkadhi
Journal:  AJNR Am J Neuroradiol       Date:  2012-02-02       Impact factor: 3.825

2.  Variation in tube voltage for adult neck MDCT: effect on radiation dose and image quality.

Authors:  Jenny K Hoang; Terry T Yoshizumi; Giao Nguyen; Greta Toncheva; Kingshuk Roy Choudhury; Andreia R Gafton; James D Eastwood; Carolyn Lowry; Lynne M Hurwitz
Journal:  AJR Am J Roentgenol       Date:  2012-03       Impact factor: 3.959

Review 3.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

4.  Combining automated attenuation-based tube voltage selection and iterative reconstruction: a liver phantom study.

Authors:  Daniela B Husarik; Sebastian T Schindera; Fabian Morsbach; Natalie Chuck; Burkhardt Seifert; Zsolt Szucs-Farkas; Hatem Alkadhi
Journal:  Eur Radiol       Date:  2013-10-24       Impact factor: 5.315

5.  Automatic selection of tube potential for radiation dose reduction in CT: a general strategy.

Authors:  Lifeng Yu; Hua Li; Joel G Fletcher; Cynthia H McCollough
Journal:  Med Phys       Date:  2010-01       Impact factor: 4.071

6.  Effective dose and organ doses estimation taking tube current modulation into account with a commercial software package.

Authors:  X Lopez-Rendon; H Bosmans; R Oyen; F Zanca
Journal:  Eur Radiol       Date:  2015-02-14       Impact factor: 5.315

7.  Automated attenuation-based tube voltage selection for body CTA: Performance evaluation of 192-slice dual-source CT.

Authors:  Anna Winklehner; Sonja Gordic; Eliane Lauk; Thomas Frauenfelder; Sebastian Leschka; Hatem Alkadhi; Daniela B Husarik
Journal:  Eur Radiol       Date:  2015-02-19       Impact factor: 5.315

8.  Objective and subjective image quality of primary and recurrent squamous cell carcinoma on head and neck low-tube-voltage 80-kVp computed tomography.

Authors:  Jan-Erik Scholtz; Moritz Kaup; Johannes Kraft; Eva-Maria Nöske; Friedrich Scheerer; Boris Schulz; Iris Burck; Jens Wagenblast; J Matthias Kerl; Ralf W Bauer; Thomas Lehnert; Thomas J Vogl; Julian L Wichmann
Journal:  Neuroradiology       Date:  2015-03-26       Impact factor: 2.804

9.  Cancer risks attributable to low doses of ionizing radiation: assessing what we really know.

Authors:  David J Brenner; Richard Doll; Dudley T Goodhead; Eric J Hall; Charles E Land; John B Little; Jay H Lubin; Dale L Preston; R Julian Preston; Jerome S Puskin; Elaine Ron; Rainer K Sachs; Jonathan M Samet; Richard B Setlow; Marco Zaider
Journal:  Proc Natl Acad Sci U S A       Date:  2003-11-10       Impact factor: 11.205

10.  Thoracoabdominal-aortoiliac multidetector-row CT angiography at 80 and 100 kVp: assessment of image quality and radiation dose.

Authors:  Sebastian T Schindera; Patricia Graca; Michael A Patak; Susanne Abderhalden; Gabriel von Allmen; Peter Vock; Zsolt Szucs-Farkas
Journal:  Invest Radiol       Date:  2009-10       Impact factor: 6.016

View more
  11 in total

1.  Impact of model-based iterative reconstruction on low-contrast lesion detection and image quality in abdominal CT: a 12-reader-based comparative phantom study with filtered back projection at different tube voltages.

Authors:  André Euler; Bram Stieltjes; Zsolt Szucs-Farkas; Reto Eichenberger; Clemens Reisinger; Anna Hirschmann; Caroline Zaehringer; Achim Kircher; Matthias Streif; Sabine Bucher; David Buergler; Luigia D'Errico; Sebastién Kopp; Markus Wilhelm; Sebastian T Schindera
Journal:  Eur Radiol       Date:  2017-04-03       Impact factor: 5.315

2.  Reaching for better image quality and lower radiation dose in head and neck CT: advanced modeled and sinogram-affirmed iterative reconstruction in combination with tube voltage adaptation.

Authors:  Andrea I Schmid; Michael Uder; Michael M Lell
Journal:  Dentomaxillofac Radiol       Date:  2016-09-08       Impact factor: 2.419

3.  Dose reduction potential of iterative reconstruction algorithms in neck CTA-a simulation study.

Authors:  Stephan Ellmann; Ferdinand Kammerer; Thomas Allmendinger; Michael Brand; Rolf Janka; Matthias Hammon; Michael M Lell; Michael Uder; Manuel Kramer
Journal:  Dentomaxillofac Radiol       Date:  2016-08-19       Impact factor: 2.419

4.  Head and neck angiography at 70 kVp with a third-generation dual-source CT system in patients: comparison with 100 kVp.

Authors:  Yu Chen; Xiaobo Zhang; Huadan Xue; Yuanli Zhu; Yun Wang; Yumei Li; Zhuhua Zhang; Zhengyu Jin
Journal:  Neuroradiology       Date:  2017-08-24       Impact factor: 2.804

5.  Diagnostic yield of 90-kVp low-tube-voltage carotid and intracerebral CT-angiography: effects on radiation dose, image quality and diagnostic performance for the detection of carotid stenosis.

Authors:  Doris Leithner; Julian L Wichmann; Scherwin Mahmoudi; Simon S Martin; Moritz H Albrecht; Thomas J Vogl; Jan-Erik Scholtz
Journal:  Br J Radiol       Date:  2018-03-08       Impact factor: 3.039

6.  Advances in cardiac CT contrast injection and acquisition protocols.

Authors:  Jan-Erik Scholtz; Brian Ghoshhajra
Journal:  Cardiovasc Diagn Ther       Date:  2017-10

7.  Single-source chest-abdomen-pelvis cancer staging on a third generation dual-source CT system: comparison of automated tube potential selection to second generation dual-source CT.

Authors:  Clara Park; Tatjana Gruber-Rouh; Doris Leithner; Amelie Zierden; Mortiz H Albrecht; Julian L Wichmann; Boris Bodelle; Mohamed Elsabaie; Jan-Erik Scholtz; Moritz Kaup; Thomas J Vogl; Martin Beeres
Journal:  Cancer Imaging       Date:  2016-10-10       Impact factor: 3.909

Review 8.  Low radiation dose in computed tomography: the role of iodine.

Authors:  Andrik J Aschoff; Carlo Catalano; Miles A Kirchin; Martin Krix; Thomas Albrecht
Journal:  Br J Radiol       Date:  2017-05-04       Impact factor: 3.039

9.  Effect of reduced z-axis scan coverage on diagnostic performance and radiation dose of neck computed tomography in patients with suspected cervical abscess.

Authors:  Jakob Weiss; Michael Maurer; Dominik Ketelsen; Mike Notohamiprodjo; Dominik Zinsser; Julian L Wichmann; Konstantin Nikolaou; Fabian Bamberg; Ahmed E Othman
Journal:  PLoS One       Date:  2017-07-05       Impact factor: 3.240

10.  Low-dose CT pulmonary angiography on a 15-year-old CT scanner: a feasibility study.

Authors:  Moritz Kaup; Tatjana Gruber-Rouh; Jan E Scholtz; Moritz H Albrecht; Andreas Bucher; Claudia Frellesen; Thomas J Vogl; Martin Beeres
Journal:  Acta Radiol Open       Date:  2016-12-01
View more