Literature DB >> 25693663

Automated attenuation-based tube voltage selection for body CTA: Performance evaluation of 192-slice dual-source CT.

Anna Winklehner1, Sonja Gordic, Eliane Lauk, Thomas Frauenfelder, Sebastian Leschka, Hatem Alkadhi, Daniela B Husarik.   

Abstract

OBJECTIVE: To assess radiation dose and image quality in body CT-angiography (CTA) with automated attenuation-based tube voltage selection (ATVS) on a 192-slice dual-source CT (DSCT).
METHODS: Forty patients (69.5 ± 9.6 years) who had undergone body CTA with ATVS (ref.kVp 100, ref.mAs 90) using a 2x192-slice CT in single-source mode were retrospectively included. All patients had undergone prior CTA with a 2x128-slice CT and ATVS with identical imaging and contrast media protocols, serving for comparison. Images were reconstructed with iterative reconstruction at similar strength levels. Radiation dose was determined. Image quality was assessed semi-quantitatively (1:excellent, 5:non-diagnostic), aortic attenuation, noise and CNR were determined.
RESULTS: As compared to 128-slice DSCT, 192-slice DSCT selected tube voltages were lower in 30 patients (75 %), higher in 3 (7.5 %), and similar in 7 patients (17.5 %). CTDIvol was lower with 192-slice DSCT (4.7 ± 1.9 mGy vs. 5.8 ± 2.1 mGy; p < 0.001). Subjective image quality, mean aortic attenuation (342 ± 67HU vs. 268 ± 67HU) and CNR (9.8 ± 2.5 vs. 8.2 ± 2.9) were higher with 192-slice DSCT (all p < 0.01), all datasets being diagnostic.
CONCLUSION: Our study suggests that ATVS of 192-slice DSCT for body CTA is associated with an improved image quality and further radiation dose reduction of 19 % compared to 128-slice DSCT. KEY POINTS: • 192-slice DSCT allows imaging from 70 kVp to 150 kVp at 10 kVp increments. • 192-slice DSCT allows for radiation-dose reduction in body-CTA with ATVS. • Subjective and objective image quality increase compared to 128-slice DSCT.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25693663     DOI: 10.1007/s00330-015-3632-4

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  20 in total

Review 1.  The care of patients with an abdominal aortic aneurysm: the Society for Vascular Surgery practice guidelines.

Authors:  Elliot L Chaikof; David C Brewster; Ronald L Dalman; Michel S Makaroun; Karl A Illig; Gregorio A Sicard; Carlos H Timaran; Gilbert R Upchurch; Frank J Veith
Journal:  J Vasc Surg       Date:  2009-10       Impact factor: 4.268

Review 2.  Reducing radiation dose in body CT: a primer on dose metrics and key CT technical parameters.

Authors:  Pierre D Maldjian; Alice R Goldman
Journal:  AJR Am J Roentgenol       Date:  2013-04       Impact factor: 3.959

3.  Next generation coronary CT angiography: in vitro evaluation of 27 coronary stents.

Authors:  Tobias Gassenmaier; Nils Petri; Thomas Allmendinger; Thomas Flohr; David Maintz; Wolfram Voelker; Thorsten A Bley
Journal:  Eur Radiol       Date:  2014-07-21       Impact factor: 5.315

4.  Using the K-edge to improve contrast conspicuity and to lower radiation dose with a 16-MDCT: a phantom and human study.

Authors:  Sanjeeva P Kalva; Dushyant V Sahani; Peter F Hahn; Sanjay Saini
Journal:  J Comput Assist Tomogr       Date:  2006 May-Jun       Impact factor: 1.826

5.  Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT angiography.

Authors:  D Fleischmann; G D Rubin; A A Bankier; K Hittmair
Journal:  Radiology       Date:  2000-02       Impact factor: 11.105

6.  Image quality and radiation dose of low tube voltage 3rd generation dual-source coronary CT angiography in obese patients: a phantom study.

Authors:  Felix G Meinel; Christian Canstein; U Joseph Schoepf; Martin Sedlmaier; Bernhard Schmidt; Brett S Harris; Thomas G Flohr; Carlo N De Cecco
Journal:  Eur Radiol       Date:  2014-05-10       Impact factor: 5.315

7.  Reduced radiation dose and improved image quality at cardiovascular CT angiography by automated attenuation-based tube voltage selection: intra-individual comparison.

Authors:  Aleksander W Krazinski; Felix G Meinel; U Joseph Schoepf; Justin R Silverman; Christian Canstein; Carlo N De Cecco; Lucas L Geyer
Journal:  Eur Radiol       Date:  2014-07-24       Impact factor: 5.315

8.  Automated low-kilovoltage selection in pediatric computed tomography angiography: phantom study evaluating effects on radiation dose and image quality.

Authors:  Marilyn Joy Siegel; Juan Carlos Ramirez-Giraldo; Charles Hildebolt; David Bradley; Bernhard Schmidt
Journal:  Invest Radiol       Date:  2013-08       Impact factor: 6.016

9.  Whole-body CT angiography with low tube voltage and low-concentration contrast material to reduce radiation dose and iodine load.

Authors:  Masayuki Kanematsu; Satoshi Goshima; Toshiharu Miyoshi; Hiroshi Kondo; Haruo Watanabe; Yoshifumi Noda; Kyongtae T Bae
Journal:  AJR Am J Roentgenol       Date:  2014-01       Impact factor: 3.959

10.  Thoracoabdominal-aortoiliac multidetector-row CT angiography at 80 and 100 kVp: assessment of image quality and radiation dose.

Authors:  Sebastian T Schindera; Patricia Graca; Michael A Patak; Susanne Abderhalden; Gabriel von Allmen; Peter Vock; Zsolt Szucs-Farkas
Journal:  Invest Radiol       Date:  2009-10       Impact factor: 6.016

View more
  11 in total

1.  Automated tube voltage selection for radiation dose and contrast medium reduction at coronary CT angiography using 3(rd) generation dual-source CT.

Authors:  Stefanie Mangold; Julian L Wichmann; U Joseph Schoepf; Zachary B Poole; Christian Canstein; Akos Varga-Szemes; Damiano Caruso; Fabian Bamberg; Konstantin Nikolaou; Carlo N De Cecco
Journal:  Eur Radiol       Date:  2016-02-04       Impact factor: 5.315

2.  Single- and dual-energy CT of the abdomen: comparison of radiation dose and image quality of 2nd and 3rd generation dual-source CT.

Authors:  Julian L Wichmann; Andrew D Hardie; U Joseph Schoepf; Lloyd M Felmly; Jonathan D Perry; Akos Varga-Szemes; Stefanie Mangold; Damiano Caruso; Christian Canstein; Thomas J Vogl; Carlo N De Cecco
Journal:  Eur Radiol       Date:  2016-05-10       Impact factor: 5.315

3.  Impact of the scout view orientation on the radiation exposure and image quality in thoracic and abdominal CT.

Authors:  S Suntharalingam; A Wetter; N Guberina; J Theysohn; A Ringelstein; T Schlosser; M Forsting; K Nassenstein
Journal:  Eur Radiol       Date:  2016-03-04       Impact factor: 5.315

4.  Diagnostic yield of 90-kVp low-tube-voltage carotid and intracerebral CT-angiography: effects on radiation dose, image quality and diagnostic performance for the detection of carotid stenosis.

Authors:  Doris Leithner; Julian L Wichmann; Scherwin Mahmoudi; Simon S Martin; Moritz H Albrecht; Thomas J Vogl; Jan-Erik Scholtz
Journal:  Br J Radiol       Date:  2018-03-08       Impact factor: 3.039

5.  Diagnostic accuracy of coronary CT angiography using 3rd-generation dual-source CT and automated tube voltage selection: Clinical application in a non-obese and obese patient population.

Authors:  Stefanie Mangold; Julian L Wichmann; U Joseph Schoepf; Damiano Caruso; Christian Tesche; Daniel H Steinberg; Akos Varga-Szemes; Andrew C Stubenrauch; Richard R Bayer; Matthew Biancalana; Konstantin Nikolaou; Carlo N De Cecco
Journal:  Eur Radiol       Date:  2016-09-28       Impact factor: 5.315

6.  Third-generation dual-source CT of the neck using automated tube voltage adaptation in combination with advanced modeled iterative reconstruction: evaluation of image quality and radiation dose.

Authors:  Jan-Erik Scholtz; Julian L Wichmann; Kristina Hüsers; Moritz H Albrecht; Martin Beeres; Ralf W Bauer; Thomas J Vogl; Boris Bodelle
Journal:  Eur Radiol       Date:  2015-11-11       Impact factor: 5.315

7.  Single- and dual-energy CT pulmonary angiography using second- and third-generation dual-source CT systems: comparison of radiation dose and image quality.

Authors:  Lukas Lenga; Franziska Trapp; Moritz H Albrecht; Julian L Wichmann; Addison A Johnson; Ibrahim Yel; Tommaso D'Angelo; Christian Booz; Thomas J Vogl; Simon S Martin
Journal:  Eur Radiol       Date:  2019-01-21       Impact factor: 5.315

8.  Head and neck single- and dual-energy CT: differences in radiation dose and image quality of 2nd and 3rd generation dual-source CT.

Authors:  Lukas Lenga; Marvin Lange; Simon S Martin; Moritz H Albrecht; Christian Booz; Ibrahim Yel; Christophe T Arendt; Thomas J Vogl; Doris Leithner
Journal:  Br J Radiol       Date:  2021-04-29       Impact factor: 3.039

9.  How Much Is the Dose Varying between Follow-Up CT-Examinations Performed on the Same Scanner with the Same Imaging Protocol?

Authors:  Saravanabavaan Suntharalingam; Franz Ferdinand Stecker; Nika Guberina; Adrian Ringelstein; Thomas Schlosser; Jens Matthias Theysohn; Michael Forsting; Kai Nassenstein
Journal:  PLoS One       Date:  2016-04-06       Impact factor: 3.240

10.  Relationship between low tube voltage (70 kV) and the iodine delivery rate (IDR) in CT angiography: An experimental in-vivo study.

Authors:  Michael M Lell; Ulrike Fleischmann; Hubertus Pietsch; Johannes G Korporaal; Ulrike Haberland; Andreas H Mahnken; Thomas G Flohr; Michael Uder; Gregor Jost
Journal:  PLoS One       Date:  2017-03-20       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.