Variation in tube voltage for adult neck MDCT: effect on radiation dose and image quality.

Jenny K Hoang1, Terry T Yoshizumi, Giao Nguyen, Greta Toncheva, Kingshuk Roy Choudhury, Andreia R Gafton, James D Eastwood, Carolyn Lowry, Lynne M Hurwitz.   

Abstract

OBJECTIVE: The purpose of this study was to assess the effect of peak kilovoltage on radiation dose and image quality in adult neck MDCT.
MATERIALS AND METHODS: An anthropomorphic phantom with metal oxide semiconductor field effect transistor detectors was imaged with a 64-MDCT scanner. The reference CT protocol called for 120 kVp, and images obtained with that protocol were compared with CT images obtained with protocols entailing 80, 100, and 140 kVp. All imaging was performed with automatic tube current modulation. Organ dose and effective dose were determined for each protocol and compared with those obtained with the 120-kVp protocol. Image noise was evaluated objectively and subjectively for each protocol.
RESULTS: The highest organ doses for all protocols were to the thyroid, ocular lens, skin, and mandible. The greatest reductions in organ dose were for the bone marrow of the cervical spine and mandible: 43% and 35% with the 100-kVp protocol and 63% and 53% with the 80-kVp protocol. Effective dose decreased as much as 9% with the 100-kVp protocol and 12% with the 80-kVp protocol. Use of the 140-kVp protocol was associated with an increase in organ dose as high as 64% for bone marrow in the cervical spine and a 19% increase in effective dose. Image noise increased with lower peak kilovoltage. The measured noise difference was greatest at 80 kVp, absolute increases were less than 2.5 HU. There was no difference in subjective image quality among protocols.
CONCLUSION: Reducing the voltage from 120 to 80 kVp for neck CT can result in greater than 50% reduction in the absorbed organ dose to the bone marrow of the cervical spine and mandible without impairment in subjective image quality.

Entities:  

Mesh:

Year:  2012        PMID: 22358002     DOI: 10.2214/AJR.11.6831

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  10 in total

1.  Computed tomography of the cervical spine: comparison of image quality between a standard-dose and a low-dose protocol using filtered back-projection and iterative reconstruction.

Authors:  Fabio Becce; Yosr Ben Salah; Francis R Verdun; Bruno C Vande Berg; Frederic E Lecouvet; Reto Meuli; Patrick Omoumi
Journal:  Skeletal Radiol       Date:  2013-01-29       Impact factor: 2.199

2.  An exponential growth in incidence of thyroid cancer: trends and impact of CT imaging.

Authors:  J K Hoang; K R Choudhury; J D Eastwood; R M Esclamado; G H Lyman; T M Shattuck; X V Nguyen
Journal:  AJNR Am J Neuroradiol       Date:  2013-10-10       Impact factor: 3.825

3.  Low-tube-voltage 80-kVp neck CT: evaluation of diagnostic accuracy and interobserver agreement.

Authors:  J L Wichmann; J Kraft; E-M Nöske; B Bodelle; I Burck; J-E Scholtz; C Frellesen; J Wagenblast; J M Kerl; R W Bauer; T Lehnert; T J Vogl; B Schulz
Journal:  AJNR Am J Neuroradiol       Date:  2014-08-07       Impact factor: 3.825

4.  Reaching for better image quality and lower radiation dose in head and neck CT: advanced modeled and sinogram-affirmed iterative reconstruction in combination with tube voltage adaptation.

Authors:  Andrea I Schmid; Michael Uder; Michael M Lell
Journal:  Dentomaxillofac Radiol       Date:  2016-09-08       Impact factor: 2.419

5.  Systematic Radiation Dose Reduction in Cervical Spine CT of Human Cadaveric Specimens: How Low Can We Go?

Authors:  M Tozakidou; C Reisinger; D Harder; J Lieb; Z Szucs-Farkas; M Müller-Gerbl; U Studler; S Schindera; A Hirschmann
Journal:  AJNR Am J Neuroradiol       Date:  2017-12-21       Impact factor: 3.825

6.  Objective and subjective image quality of primary and recurrent squamous cell carcinoma on head and neck low-tube-voltage 80-kVp computed tomography.

Authors:  Jan-Erik Scholtz; Moritz Kaup; Johannes Kraft; Eva-Maria Nöske; Friedrich Scheerer; Boris Schulz; Iris Burck; Jens Wagenblast; J Matthias Kerl; Ralf W Bauer; Thomas Lehnert; Thomas J Vogl; Julian L Wichmann
Journal:  Neuroradiology       Date:  2015-03-26       Impact factor: 2.804

7.  Third-generation dual-source CT of the neck using automated tube voltage adaptation in combination with advanced modeled iterative reconstruction: evaluation of image quality and radiation dose.

Authors:  Jan-Erik Scholtz; Julian L Wichmann; Kristina Hüsers; Moritz H Albrecht; Martin Beeres; Ralf W Bauer; Thomas J Vogl; Boris Bodelle
Journal:  Eur Radiol       Date:  2015-11-11       Impact factor: 5.315

8.  Emergency CT head and neck imaging: effects of swimmer's position on dose and image quality.

Authors:  Fabian G Mueck; Sebastian Roesch; Lucas Geyer; Michael Scherr; Michael Seidenbusch; Robert Stahl; Zsuzsanna Deak; Stefan Wirth
Journal:  Eur Radiol       Date:  2014-02-15       Impact factor: 5.315

9.  Combined Use of Automatic Tube Voltage Selection and Current Modulation with Iterative Reconstruction for CT Evaluation of Small Hypervascular Hepatocellular Carcinomas: Effect on Lesion Conspicuity and Image Quality.

Authors:  Peijie Lv; Jie Liu; Rui Zhang; Yan Jia; Jianbo Gao
Journal:  Korean J Radiol       Date:  2015-05-13       Impact factor: 3.500

10.  Variation in tube voltage for pediatric neck 64VCT: Effect on radiation dose and image quality.

Authors:  Li-Guo Chen; Ping-An Wu; Hsing-Yang Tu; Ming-Huei Sheu; Li-Chuan Huang
Journal:  PLoS One       Date:  2021-11-12       Impact factor: 3.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.