Literature DB >> 18072519

A three-dimensional statistical approach to improved image quality for multislice helical CT.

Jean-Baptiste Thibault1, Ken D Sauer, Charles A Bouman, Jiang Hsieh.   

Abstract

Multislice helical computed tomography scanning offers the advantages of faster acquisition and wide organ coverage for routine clinical diagnostic purposes. However, image reconstruction is faced with the challenges of three-dimensional cone-beam geometry, data completeness issues, and low dosage. Of all available reconstruction methods, statistical iterative reconstruction (IR) techniques appear particularly promising since they provide the flexibility of accurate physical noise modeling and geometric system description. In this paper, we present the application of Bayesian iterative algorithms to real 3D multislice helical data to demonstrate significant image quality improvement over conventional techniques. We also introduce a novel prior distribution designed to provide flexibility in its parameters to fine-tune image quality. Specifically, enhanced image resolution and lower noise have been achieved, concurrently with the reduction of helical cone-beam artifacts, as demonstrated by phantom studies. Clinical results also illustrate the capabilities of the algorithm on real patient data. Although computational load remains a significant challenge for practical development, superior image quality combined with advancements in computing technology make IR techniques a legitimate candidate for future clinical applications.

Entities:  

Mesh:

Year:  2007        PMID: 18072519     DOI: 10.1118/1.2789499

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  248 in total

1.  Regularization designs for uniform spatial resolution and noise properties in statistical image reconstruction for 3-D X-ray CT.

Authors:  Jang Hwan Cho; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2014-10-28       Impact factor: 10.048

2.  Non-invasive assessment of functionally relevant coronary artery stenoses with quantitative CT perfusion: preliminary clinical experiences.

Authors:  Aaron So; Gerald Wisenberg; Ali Islam; Justin Amann; Walter Romano; James Brown; Dennis Humen; George Jablonsky; Jian-Ying Li; Jiang Hsieh; Ting-Yim Lee
Journal:  Eur Radiol       Date:  2011-09-21       Impact factor: 5.315

3.  Iterative reconstruction in head CT: image quality of routine and low-dose protocols in comparison with standard filtered back-projection.

Authors:  A Korn; M Fenchel; B Bender; S Danz; T K Hauser; D Ketelsen; T Flohr; C D Claussen; M Heuschmid; U Ernemann; H Brodoefel
Journal:  AJNR Am J Neuroradiol       Date:  2011-10-27       Impact factor: 3.825

4.  A strategy to decrease partial scan reconstruction artifacts in myocardial perfusion CT: phantom and in vivo evaluation.

Authors:  Juan C Ramirez-Giraldo; Lifeng Yu; Birgit Kantor; Erik L Ritman; Cynthia H McCollough
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

5.  Prior image constrained compressed sensing: implementation and performance evaluation.

Authors:  Pascal Thériault Lauzier; Jie Tang; Guang-Hong Chen
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

6.  Impact of iterative reconstruction on image quality and radiation dose in multidetector CT of large body size adults.

Authors:  Gaurav S Desai; Raul N Uppot; Elaine W Yu; Avinash R Kambadakone; Dushyant V Sahani
Journal:  Eur Radiol       Date:  2012-04-19       Impact factor: 5.315

7.  Radiation dose reduction in temporal bone CT with iterative reconstruction technique.

Authors:  Y T Niu; D Mehta; Z R Zhang; Y X Zhang; Y F Liu; T L Kang; J F Xian; Z C Wang
Journal:  AJNR Am J Neuroradiol       Date:  2012-02-09       Impact factor: 3.825

8.  A Feasibility Study of Extracting Tissue Textures From a Previous Full-Dose CT Database as Prior Knowledge for Bayesian Reconstruction of Current Low-Dose CT Images.

Authors:  Yongfeng Gao; Zhengrong Liang; William Moore; Hao Zhang; Marc J Pomeroy; John A Ferretti; Thomas V Bilfinger; Jianhua Ma; Hongbing Lu
Journal:  IEEE Trans Med Imaging       Date:  2019-01-03       Impact factor: 10.048

9.  Sparsity-regularized image reconstruction of decomposed K-edge data in spectral CT.

Authors:  Qiaofeng Xu; Alex Sawatzky; Mark A Anastasio; Carsten O Schirra
Journal:  Phys Med Biol       Date:  2014-04-28       Impact factor: 3.609

Review 10.  Recent and future directions in CT imaging.

Authors:  Norbert J Pelc
Journal:  Ann Biomed Eng       Date:  2014-01-17       Impact factor: 3.934

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.