Inverse determination of the penalty parameter in penalized weighted least-squares algorithm for noise reduction of low-dose CBCT.

Jing Wang1, Huaiqun Guan, Timothy Solberg.   

Abstract

PURPOSE: A statistical projection restoration algorithm based on the penalized weighted least-squares (PWLS) criterion can substantially improve the image quality of low-dose CBCT images. The performance of PWLS is largely dependent on the choice of the penalty parameter. Previously, the penalty parameter was chosen empirically by trial and error. In this work, the authors developed an inverse technique to calculate the penalty parameter in PWLS for noise suppression of low-dose CBCT in image guided radiotherapy (IGRT).
METHODS: In IGRT, a daily CBCT is acquired for the same patient during a treatment course. In this work, the authors acquired the CBCT with a high-mAs protocol for the first session and then a lower mAs protocol for the subsequent sessions. The high-mAs projections served as the goal (ideal) toward, which the low-mAs projections were to be smoothed by minimizing the PWLS objective function. The penalty parameter was determined through an inverse calculation of the derivative of the objective function incorporating both the high and low-mAs projections. Then the parameter obtained can be used for PWLS to smooth the noise in low-dose projections. CBCT projections for a CatPhan 600 and an anthropomorphic head phantom, as well as for a brain patient, were used to evaluate the performance of the proposed technique.
RESULTS: The penalty parameter in PWLS was obtained for each CBCT projection using the proposed strategy. The noise in the low-dose CBCT images reconstructed from the smoothed projections was greatly suppressed. Image quality in PWLS-processed low-dose CBCT was comparable to its corresponding high-dose CBCT.
CONCLUSIONS: A technique was proposed to estimate the penalty parameter for PWLS algorithm. It provides an objective and efficient way to obtain the penalty parameter for image restoration algorithms that require predefined smoothing parameters.

Entities:  

Mesh:

Year:  2011        PMID: 21859005     DOI: 10.1118/1.3600696

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  11 in total

1.  Using compressive sensing to recover images from PET scanners with partial detector rings.

Authors:  SeyyedMajid Valiollahzadeh; John W Clark; Osama Mawlawi
Journal:  Med Phys       Date:  2015-01       Impact factor: 4.071

2.  Accelerated barrier optimization compressed sensing (ABOCS) reconstruction for cone-beam CT: phantom studies.

Authors:  Tianye Niu; Lei Zhu
Journal:  Med Phys       Date:  2012-07       Impact factor: 4.071

3.  SR-NLM: a sinogram restoration induced non-local means image filtering for low-dose computed tomography.

Authors:  Zhaoying Bian; Jianhua Ma; Jing Huang; Hua Zhang; Shanzhou Niu; Qianjin Feng; Zhengrong Liang; Wufan Chen
Journal:  Comput Med Imaging Graph       Date:  2013-06-24       Impact factor: 4.790

4.  Sparse-view x-ray CT reconstruction via total generalized variation regularization.

Authors:  Shanzhou Niu; Yang Gao; Zhaoying Bian; Jing Huang; Wufan Chen; Gaohang Yu; Zhengrong Liang; Jianhua Ma
Journal:  Phys Med Biol       Date:  2014-05-19       Impact factor: 3.609

5.  Iterative reconstruction for CT perfusion with a prior-image induced hybrid nonlocal means regularization: Phantom studies.

Authors:  Bin Li; Qingwen Lyu; Jianhua Ma; Jing Wang
Journal:  Med Phys       Date:  2016-04       Impact factor: 4.071

6.  [Total generalized variation minimization based on projection data for low?dose CT reconstruction].

Authors:  Shan-Zhou Niu; Heng Wu; Ze-Feng Yu; Zi-Jun Zheng; Gao-Hang Yu
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2017-12-20

7.  An Efficient Augmented Lagrangian Method for Statistical X-Ray CT Image Reconstruction.

Authors:  Jiaojiao Li; Shanzhou Niu; Jing Huang; Zhaoying Bian; Qianjin Feng; Gaohang Yu; Zhengrong Liang; Wufan Chen; Jianhua Ma
Journal:  PLoS One       Date:  2015-10-23       Impact factor: 3.240

8.  Low-dose cerebral perfusion computed tomography image restoration via low-rank and total variation regularizations.

Authors:  Shanzhou Niu; Shanli Zhang; Jing Huang; Zhaoying Bian; Wufan Chen; Gaohang Yu; Zhengrong Liang; Jianhua Ma
Journal:  Neurocomputing       Date:  2016-03-28       Impact factor: 5.719

9.  MULTI-ENERGY CONE-BEAM CT RECONSTRUCTION WITH A SPATIAL SPECTRAL NONLOCAL MEANS ALGORITHM.

Authors:  Bin Li; Chenyang Shen; Yujie Chi; Ming Yang; Yifei Lou; Linghong Zhou; Xun Jia
Journal:  SIAM J Imaging Sci       Date:  2018-05-08       Impact factor: 2.867

10.  Iterative reconstruction for photon-counting CT using prior image constrained total generalized variation.

Authors:  Shanzhou Niu; You Zhang; Yuncheng Zhong; Guoliang Liu; Shaohui Lu; Xile Zhang; Shengzhou Hu; Tinghua Wang; Gaohang Yu; Jing Wang
Journal:  Comput Biol Med       Date:  2018-10-22       Impact factor: 4.589

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.