Literature DB >> 29292249

[Total generalized variation minimization based on projection data for low?dose CT reconstruction].

Shan-Zhou Niu1, Heng Wu, Ze-Feng Yu, Zi-Jun Zheng, Gao-Hang Yu.   

Abstract

OBJECTIVE: To obtain high?quality low?dose CT images using total generalized variation regularization based on the projection data for low?dose CT reconstruction.
METHODS: The projection data of the CT images were transformed from Poisson distribution to Gaussian distribution using the linear Anscombe transform. The transformed data were then restored by an efficient total generalized variation minimization algorithm. Reconstruction was finally achieved by inverse Anscombe transform and filtered back projection (FBP) method.
RESULTS: The image quality of low?dose CT was greatly improved by the proposed algorithm in both Clock and Shepp?Logan phantoms. The signal?to?noise ratios (SNRs) of the Clock and Shepp-Logan images reconstructed by FBP algorithm were 17.752 dB and 19.379 dB, which were increased by the proposed algorithm to 24.0352 and 23.4181 dB, respectively. The NMSE of the Clock and Shepp?Logan images reconstructed by FBP algorithm was 0.86% and 0.58%, which was reduced by the proposed algorithm to 0.2% and 0.23%, respectively.
CONCLUSION: The proposed method can effectively suppress noise and strip artifacts in low?dose CT images when piecewise constant assumption is not possible.

Mesh:

Year:  2017        PMID: 29292249      PMCID: PMC6744009     

Source DB:  PubMed          Journal:  Nan Fang Yi Ke Da Xue Xue Bao        ISSN: 1673-4254


  20 in total

1.  Noise Reduction for Low-Dose Single-Slice Helical CT Sinograms.

Authors:  Jing Wang; Tianfang Li; Hongbing Lu; Zhengrong Liang
Journal:  IEEE Trans Nucl Sci       Date:  2006-06       Impact factor: 1.679

2.  Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose X-ray computed tomography.

Authors:  Jing Wang; Tianfang Li; Hongbing Lu; Zhengrong Liang
Journal:  IEEE Trans Med Imaging       Date:  2006-10       Impact factor: 10.048

3.  Multiscale penalized weighted least-squares sinogram restoration for low-dose X-ray computed tomography.

Authors:  Jing Wang; Zhengrong Liang; Hongbing Lu
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2006

4.  Sparse angular CT reconstruction using non-local means based iterative-correction POCS.

Authors:  Jing Huang; Jianhua Ma; Nan Liu; Hua Zhang; Zhaoying Bian; Yanqiu Feng; Qianjin Feng; Wufan Chen
Journal:  Comput Biol Med       Date:  2011-02-21       Impact factor: 4.589

5.  Inverse determination of the penalty parameter in penalized weighted least-squares algorithm for noise reduction of low-dose CBCT.

Authors:  Jing Wang; Huaiqun Guan; Timothy Solberg
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

6.  Iterative reconstruction for sparse-view x-ray CT using alpha-divergence constrained total generalized variation minimization.

Authors:  Shanzhou Niu; Jing Huang; Zhaoying Bian; Dong Zeng; Wufan Chen; Gaohang Yu; Zhengrong Liang; Jianhua Ma
Journal:  J Xray Sci Technol       Date:  2017-04-05       Impact factor: 1.535

7.  Low-dose X-ray computed tomography image reconstruction with a combined low-mAs and sparse-view protocol.

Authors:  Yang Gao; Zhaoying Bian; Jing Huang; Yunwan Zhang; Shanzhou Niu; Qianjin Feng; Wufan Chen; Zhengrong Liang; Jianhua Ma
Journal:  Opt Express       Date:  2014-06-16       Impact factor: 3.894

8.  Second order total generalized variation (TGV) for MRI.

Authors:  Florian Knoll; Kristian Bredies; Thomas Pock; Rudolf Stollberger
Journal:  Magn Reson Med       Date:  2010-12-08       Impact factor: 4.668

9.  A new CT reconstruction technique using adaptive deformation recovery and intensity correction (ADRIC).

Authors:  You Zhang; Jianhua Ma; Puneeth Iyengar; Yuncheng Zhong; Jing Wang
Journal:  Med Phys       Date:  2017-05-12       Impact factor: 4.071

10.  Iterative image reconstruction for sparse-view CT using normal-dose image induced total variation prior.

Authors:  Jing Huang; Yunwan Zhang; Jianhua Ma; Dong Zeng; Zhaoying Bian; Shanzhou Niu; Qianjin Feng; Zhengrong Liang; Wufan Chen
Journal:  PLoS One       Date:  2013-11-18       Impact factor: 3.240

View more
  1 in total

1.  [Nonlocal low-rank and sparse matrix decomposition for low-dose cerebral perfusion CT image restoration].

Authors:  S Niu; H Liu; P Liu; M Zhang; S Li; L Liang; N Li; G Liu
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2022-09-20
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.