Literature DB >> 24593724

Noise correlation in CBCT projection data and its application for noise reduction in low-dose CBCT.

Hua Zhang1, Luo Ouyang2, Jianhua Ma3, Jing Huang3, Wufan Chen3, Jing Wang2.   

Abstract

PURPOSE: To study the noise correlation properties of cone-beam CT (CBCT) projection data and to incorporate the noise correlation information to a statistics-based projection restoration algorithm for noise reduction in low-dose CBCT.
METHODS: In this study, the authors systematically investigated the noise correlation properties among detector bins of CBCT projection data by analyzing repeated projection measurements. The measurements were performed on a TrueBeam onboard CBCT imaging system with a 4030CB flat panel detector. An anthropomorphic male pelvis phantom was used to acquire 500 repeated projection data at six different dose levels from 0.1 to 1.6 mAs per projection at three fixed angles. To minimize the influence of the lag effect, lag correction was performed on the consecutively acquired projection data. The noise correlation coefficient between detector bin pairs was calculated from the corrected projection data. The noise correlation among CBCT projection data was then incorporated into the covariance matrix of the penalized weighted least-squares (PWLS) criterion for noise reduction of low-dose CBCT.
RESULTS: The analyses of the repeated measurements show that noise correlation coefficients are nonzero between the nearest neighboring bins of CBCT projection data. The average noise correlation coefficients for the first- and second-order neighbors are 0.20 and 0.06, respectively. The noise correlation coefficients are independent of the dose level. Reconstruction of the pelvis phantom shows that the PWLS criterion with consideration of noise correlation (PWLS-Cor) results in a lower noise level as compared to the PWLS criterion without considering the noise correlation (PWLS-Dia) at the matched resolution. At the 2.0 mm resolution level in the axial-plane noise resolution tradeoff analysis, the noise level of the PWLS-Cor reconstruction is 6.3% lower than that of the PWLS-Dia reconstruction.
CONCLUSIONS: Noise is correlated among nearest neighboring detector bins of CBCT projection data. An accurate noise model of CBCT projection data can improve the performance of the statistics-based projection restoration algorithm for low-dose CBCT.

Entities:  

Mesh:

Year:  2014        PMID: 24593724     DOI: 10.1118/1.4865782

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  15 in total

1.  Penalized-Likelihood Reconstruction With High-Fidelity Measurement Models for High-Resolution Cone-Beam Imaging.

Authors:  Steven Tilley; Matthew Jacobson; Qian Cao; Michael Brehler; Alejandro Sisniega; Wojciech Zbijewski; J Webster Stayman
Journal:  IEEE Trans Med Imaging       Date:  2018-04       Impact factor: 10.048

2.  Structure-adaptive CBCT reconstruction using weighted total variation and Hessian penalties.

Authors:  Qi Shi; Nanbo Sun; Tao Sun; Jing Wang; Shan Tan
Journal:  Biomed Opt Express       Date:  2016-08-09       Impact factor: 3.732

3.  Nonlinear Statistical Reconstruction for Flat-Panel Cone-Beam CT with Blur and Correlated Noise Models.

Authors:  Steven Tilley; Jeffrey H Siewerdsen; Wojciech Zbijewski; J Webster Stayman
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-22

4.  [Low-dose digital breast tomosynthsis imaging via noise correlation based penalized weighted least-squares algorithm].

Authors:  Meiling Chen; Xi Tao; Huayong Li; Wufan Chen; Hua Zhang
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2018-01-30

5.  Enabling machine learning in X-ray-based procedures via realistic simulation of image formation.

Authors:  Mathias Unberath; Jan-Nico Zaech; Cong Gao; Bastian Bier; Florian Goldmann; Sing Chun Lee; Javad Fotouhi; Russell Taylor; Mehran Armand; Nassir Navab
Journal:  Int J Comput Assist Radiol Surg       Date:  2019-06-11       Impact factor: 2.924

6.  Data correlation based noise level estimation for cone beam projection data.

Authors:  Ti Bai; Hao Yan; Luo Ouyang; David Staub; Jing Wang; Xun Jia; Steve B Jiang; Xuanqin Mou
Journal:  J Xray Sci Technol       Date:  2017       Impact factor: 1.535

7.  Statistical CT reconstruction using region-aware texture preserving regularization learning from prior normal-dose CT image.

Authors:  Xiao Jia; Yuting Liao; Dong Zeng; Hao Zhang; Yuanke Zhang; Ji He; Zhaoying Bian; Yongbo Wang; Xi Tao; Zhengrong Liang; Jing Huang; Jianhua Ma
Journal:  Phys Med Biol       Date:  2018-11-20       Impact factor: 3.609

8.  An Efficient Augmented Lagrangian Method for Statistical X-Ray CT Image Reconstruction.

Authors:  Jiaojiao Li; Shanzhou Niu; Jing Huang; Zhaoying Bian; Qianjin Feng; Gaohang Yu; Zhengrong Liang; Wufan Chen; Jianhua Ma
Journal:  PLoS One       Date:  2015-10-23       Impact factor: 3.240

9.  Blind deconvolution in model-based iterative reconstruction for CT using a normalized sparsity measure.

Authors:  Lorenz Hehn; Steven Tilley; Franz Pfeiffer; J Webster Stayman
Journal:  Phys Med Biol       Date:  2019-10-31       Impact factor: 3.609

10.  Model-based iterative reconstruction for flat-panel cone-beam CT with focal spot blur, detector blur, and correlated noise.

Authors:  Steven Tilley; Jeffrey H Siewerdsen; J Webster Stayman
Journal:  Phys Med Biol       Date:  2015-12-09       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.