Literature DB >> 26377826

Channel Interaction and Current Level Affect Across-Electrode Integration of Interaural Time Differences in Bilateral Cochlear-Implant Listeners.

Katharina Egger1, Piotr Majdak2, Bernhard Laback3.   

Abstract

Sensitivity to interaural time differences (ITDs) is important for sound localization. Normal-hearing listeners benefit from across-frequency processing, as seen with improved ITD thresholds when consistent ITD cues are presented over a range of frequency channels compared with when ITD information is only presented in a single frequency channel. This study aimed to clarify whether cochlear-implant (CI) listeners can make use of similar processing when being stimulated with multiple interaural electrode pairs transmitting consistent ITD information. ITD thresholds for unmodulated, 100-pulse-per-second pulse trains were measured in seven bilateral CI listeners using research interfaces. Consistent ITDs were presented at either one or two electrode pairs at different current levels, allowing for comparisons at either constant level per component electrode or equal overall loudness. Different tonotopic distances between the pairs were tested in order to clarify the potential influence of channel interaction. Comparison of ITD thresholds between double pairs and the respective single pairs revealed systematic effects of tonotopic separation and current level. At constant levels, performance with double-pair stimulation improved compared with single-pair stimulation but only for large tonotopic separation. Comparisons at equal overall loudness revealed no benefit from presenting ITD information at two electrode pairs for any tonotopic spacing. Irrespective of electrode-pair configuration, ITD sensitivity improved with increasing current level. Hence, the improved ITD sensitivity for double pairs found for a large tonotopic separation and constant current levels seems to be due to increased loudness. The overall data suggest that CI listeners can benefit from combining consistent ITD information across multiple electrodes, provided sufficient stimulus levels and that stimulating electrode pairs are widely spaced.

Keywords:  ITD sensitivity; across-frequency processing; binaural timing cues; multiple-electrode stimulation

Mesh:

Year:  2015        PMID: 26377826      PMCID: PMC4722017          DOI: 10.1007/s10162-015-0542-8

Source DB:  PubMed          Journal:  J Assoc Res Otolaryngol        ISSN: 1438-7573


  30 in total

1.  Effects of stimulation mode, level and location on forward-masked excitation patterns in cochlear implant patients.

Authors:  Monita Chatterjee; John J Galvin; Qian-Jie Fu; Robert V Shannon
Journal:  J Assoc Res Otolaryngol       Date:  2005-11-04

2.  Effects of interaural time differences in fine structure and envelope on lateral discrimination in electric hearing.

Authors:  Piotr Majdak; Bernhard Laback; Wolf-Dieter Baumgartner
Journal:  J Acoust Soc Am       Date:  2006-10       Impact factor: 1.840

3.  Combination of binaural information across frequency bands.

Authors:  T N Buell; E R Hafter
Journal:  J Acoust Soc Am       Date:  1991-10       Impact factor: 1.840

4.  Sensitivity to binaural timing in bilateral cochlear implant users.

Authors:  Richard J M van Hoesel
Journal:  J Acoust Soc Am       Date:  2007-04       Impact factor: 1.840

Review 5.  Simultaneous inference in general parametric models.

Authors:  Torsten Hothorn; Frank Bretz; Peter Westfall
Journal:  Biom J       Date:  2008-06       Impact factor: 2.207

Review 6.  Perception and coding of interaural time differences with bilateral cochlear implants.

Authors:  Bernhard Laback; Katharina Egger; Piotr Majdak
Journal:  Hear Res       Date:  2014-10-19       Impact factor: 3.208

7.  Modulation frequency discrimination with single and multiple channels in cochlear implant users.

Authors:  John J Galvin; Sandy Oba; Deniz Başkent; Qian-Jie Fu
Journal:  Hear Res       Date:  2015-03-05       Impact factor: 3.208

8.  An adaptive procedure for subjective judgments.

Authors:  W Jesteadt
Journal:  Percept Psychophys       Date:  1980-07

9.  Effect of age at onset of deafness on binaural sensitivity in electric hearing in humans.

Authors:  Ruth Y Litovsky; Gary L Jones; Smita Agrawal; Richard van Hoesel
Journal:  J Acoust Soc Am       Date:  2010-01       Impact factor: 1.840

10.  Single- and multi-channel modulation detection in cochlear implant users.

Authors:  John J Galvin; Sandy Oba; Qian-Jie Fu; Deniz Başkent
Journal:  PLoS One       Date:  2014-06-11       Impact factor: 3.240

View more
  15 in total

1.  Effect of multi-electrode configuration on sensitivity to interaural timing differences in bilateral cochlear-implant users.

Authors:  Alan Kan; Heath G Jones; Ruth Y Litovsky
Journal:  J Acoust Soc Am       Date:  2015-12       Impact factor: 1.840

Review 2.  [Bilateral cochlear implants].

Authors:  J Müller
Journal:  HNO       Date:  2017-07       Impact factor: 1.284

3.  Spatial attention in bilateral cochlear-implant users.

Authors:  Matthew J Goupell; Alan Kan; Ruth Y Litovsky
Journal:  J Acoust Soc Am       Date:  2016-09       Impact factor: 1.840

4.  Lateralization of interaural timing differences with multi-electrode stimulation in bilateral cochlear-implant users.

Authors:  Alan Kan; Heath G Jones; Ruth Y Litovsky
Journal:  J Acoust Soc Am       Date:  2016-11       Impact factor: 1.840

5.  Interaural Time Difference Perception with a Cochlear Implant and a Normal Ear.

Authors:  Tom Francart; Konstantin Wiebe; Thomas Wesarg
Journal:  J Assoc Res Otolaryngol       Date:  2018-09-27

6.  Introducing Short Interpulse Intervals in High-Rate Pulse Trains Enhances Binaural Timing Sensitivity in Electric Hearing.

Authors:  Sridhar Srinivasan; Bernhard Laback; Piotr Majdak; Bertrand Delgutte
Journal:  J Assoc Res Otolaryngol       Date:  2018-03-16

7.  Mixed stimulation rates to improve sensitivity of interaural timing differences in bilateral cochlear implant listeners.

Authors:  Tanvi Thakkar; Alan Kan; Heath G Jones; Ruth Y Litovsky
Journal:  J Acoust Soc Am       Date:  2018-03       Impact factor: 1.840

8.  Improving Interaural Time Difference Sensitivity Using Short Inter-pulse Intervals with Amplitude-Modulated Pulse Trains in Bilateral Cochlear Implants.

Authors:  Sridhar Srinivasan; Bernhard Laback; Piotr Majdak; Christoph Arnoldner
Journal:  J Assoc Res Otolaryngol       Date:  2020-02-10

9.  Effect of channel separation and interaural mismatch on fusion and lateralization in normal-hearing and cochlear-implant listeners.

Authors:  Alan Kan; Matthew J Goupell; Ruth Y Litovsky
Journal:  J Acoust Soc Am       Date:  2019-08       Impact factor: 1.840

10.  Neural Coding of Interaural Time Differences with Bilateral Cochlear Implants in Unanesthetized Rabbits.

Authors:  Yoojin Chung; Kenneth E Hancock; Bertrand Delgutte
Journal:  J Neurosci       Date:  2016-05-18       Impact factor: 6.167

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.