| Literature DB >> 27908067 |
Alan Kan1, Heath G Jones2, Ruth Y Litovsky3.
Abstract
Bilateral cochlear implant (BiCI) users have shown variability in interaural time difference (ITD) sensitivity at different places along the cochlea. This paper investigates perception of multi-electrode binaural stimulation to determine if auditory object formation (AOF) and lateralization are affected by variability in ITD sensitivity when a complex sound is encoded with multi-channel processing. AOF and ITD lateralization were compared between single- and multi-electrode configurations. Most (7/8) BiCI users perceived a single auditory object with multi-electrode stimulation, and the range of lateralization was comparable to single-electrode stimulation, suggesting that variability in single-electrode ITD sensitivity does not compromise AOF with multi-electrode stimulation.Mesh:
Year: 2016 PMID: 27908067 PMCID: PMC5392091 DOI: 10.1121/1.4967014
Source DB: PubMed Journal: J Acoust Soc Am ISSN: 0001-4966 Impact factor: 1.840