Literature DB >> 26115695

The effect of pupil dilation on AL-Scan biometric parameters.

Ertuğrul Can1, Mustafa Duran2, Tuğba Çetinkaya2, Nurşen Arıtürk2.   

Abstract

The purpose of this study was to investigate the effects of pupil dilation on the parameters of the AL-Scan (Nidek Co., Ltd, Gamagori, Japan). We compared the measurements of axial length (AL), anterior chamber depth (ACD), central corneal keratometry reading, pupil diameter, and intraocular lens (IOL) power of 72 eyes of 72 healthy volunteers and patients scheduled for cataract surgery before and 45 min after instillation of cyclopentolate hydrochloride 1 % using the AL-Scan. Intraobserver repeatability was assessed by taking three consecutive recordings of ACD and AL. Only ACD readings were significantly different between predilation and postdilation (P < 0.001). The difference of the other measurements between two sessions was not statistically significant (P > 0.001). Only two cases in the study demonstrated changes in IOL power higher than 0.5 D. The intraobserver repeatability of both devices was good (CV values for ACD and AL were 0.16 and 0.20 %, respectively). Dilated pupil size did not affect the measurement of IOL power using the A-Scan optical biometer, but increase in ACD after dilation should be taken into account when performing refractive surgeries in which ACD is very important such as phakic anterior chamber IOL implantation.

Entities:  

Keywords:  AL-Scan; Anterior chamber depth; Axial length; Optical biometry

Mesh:

Substances:

Year:  2015        PMID: 26115695     DOI: 10.1007/s10792-015-0097-z

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  15 in total

1.  Evaluation of the practicality of optical biometry and applanation ultrasound in 253 eyes.

Authors:  Mana Tehrani; Frank Krummenauer; Eric Blom; H Burkhard Dick
Journal:  J Cataract Refract Surg       Date:  2003-04       Impact factor: 3.351

2.  A new optical low coherence reflectometry device for ocular biometry in cataract patients.

Authors:  P J Buckhurst; J S Wolffsohn; S Shah; S A Naroo; L N Davies; E J Berrow
Journal:  Br J Ophthalmol       Date:  2009-04-19       Impact factor: 4.638

3.  Accuracy of a new partial coherence interferometry analyser for biometric measurements.

Authors:  M P Holzer; M Mamusa; G U Auffarth
Journal:  Br J Ophthalmol       Date:  2009-03-15       Impact factor: 4.638

4.  Effect of pharmacologic pupil dilation on OLCR optical biometry measurements for IOL predictions.

Authors:  Pedro Arriola-Villalobos; David Díaz-Valle; Nuria Garzòn; Jorge Ruiz-Medrano; Cristina Fernández-Perez; Nicolás Alejandre-Alba; Julián García-Feijoò
Journal:  Eur J Ophthalmol       Date:  2013-06-17       Impact factor: 2.597

5.  Intraocular lens power calculation with an improved anterior chamber depth prediction algorithm.

Authors:  T Olsen; L Corydon; H Gimbel
Journal:  J Cataract Refract Surg       Date:  1995-05       Impact factor: 3.351

6.  Standardizing constants for ultrasonic biometry, keratometry, and intraocular lens power calculations.

Authors:  J T Holladay
Journal:  J Cataract Refract Surg       Date:  1997-11       Impact factor: 3.351

7.  The effect of pupil dilation on biometric parameters of the Lenstar 900.

Authors:  Berker Bakbak; Bengu E Koktekir; Sansal Gedik; Huseyin Guzel
Journal:  Cornea       Date:  2013-04       Impact factor: 2.651

8.  Influences of cyclopentolate hydrochloride on anterior segment parameters with Pentacam in children.

Authors:  Melis Palamar; Sait Egrilmez; Onder Uretmen; Ayse Yagci; Suheyla Kose
Journal:  Acta Ophthalmol       Date:  2011-02-21       Impact factor: 3.761

9.  Partial coherence interferometry: a novel approach to biometry in cataract surgery.

Authors:  W Drexler; O Findl; R Menapace; G Rainer; C Vass; C K Hitzenberger; A F Fercher
Journal:  Am J Ophthalmol       Date:  1998-10       Impact factor: 5.258

10.  Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis.

Authors:  W Haigis; B Lege; N Miller; B Schneider
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2000-09       Impact factor: 3.117

View more
  2 in total

1.  Evaluating relaxed ciliary muscle tone in presbyopic eyes.

Authors:  Erhan Özyol; Pelin Özyol
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-02-25       Impact factor: 3.117

2.  Influence of pupil dilation on the Barrett universal II (new generation), Haigis (4th generation), and SRK/T (3rd generation) intraocular lens calculation formulas: a retrospective study.

Authors:  Takeshi Teshigawara; Akira Meguro; Nobuhisa Mizuki
Journal:  BMC Ophthalmol       Date:  2020-07-20       Impact factor: 2.209

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.