Intraocular lens power calculation with an improved anterior chamber depth prediction algorithm.

T Olsen1, L Corydon, H Gimbel.   

Abstract

The accuracy of intraocular lens (IOL) power calculation was evaluated in a multicenter study of 822 IOL implantations using the Binkhorst II, Sanders/Retzlaff/Kraff (SRK I, SRK II, SRK/T), Holladay, and Olsen formulas. All but the first of these were optimized in retrospect with calculation of the SRK A-constant, the Holladay surgeon factor, and the Olsen pseudophakic anterior chamber depth (ACD) for each lens style. The ACD prediction of the Olsen formula was based on a previously described regression formula incorporating preoperative ACD, corneal height, axial length, and lens thickness. Among the optical IOL power calculation formulas, the highest IOL power prediction error was found with Binkhorst's and the lowest with Olsen's, which was more accurate than the SRK/T and the Holladay formulas (P < .05). The SRK/T formula was significantly more accurate than the original SRK regression formulas (P < .001). When analyzed for axial length dependence, all formulas showed the least error in the normal range. Error of the Olsen formula was lower than that of the others in the axial length interval 20 mm to 26 mm. No differences in accuracy were found between the optical IOL calculation formulas in eyes with an axial length above 26 mm (P < .05). The accuracy of IOL power calculation can be improved with optical formulas using newer-generation ACD-prediction algorithms.

Entities:  

Mesh:

Year:  1995        PMID: 7674170     DOI: 10.1016/s0886-3350(13)80140-x

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  28 in total

1.  [Effect of applanation tonometry on precision of biometry measurements].

Authors:  T M Rabsilber; S Bueltmann; M P Holzer; G U Auffarth
Journal:  Ophthalmologe       Date:  2011-01       Impact factor: 1.059

2.  Intra-ocular lens power calculation in patients with high axial myopia before cataract surgery.

Authors:  Raouf El-Nafees; Ashraf Moawad; Hanem Kishk; Walid Gaafar
Journal:  Saudi J Ophthalmol       Date:  2010-04-04

3.  [Determination of toric intraocular lenses].

Authors:  A Langenbucher; Anja Viestenz; N Szentmáry; W Behrens-Baumann; A Viestenz
Journal:  Ophthalmologe       Date:  2008-07       Impact factor: 1.059

4.  The effect of pupil dilation on AL-Scan biometric parameters.

Authors:  Ertuğrul Can; Mustafa Duran; Tuğba Çetinkaya; Nurşen Arıtürk
Journal:  Int Ophthalmol       Date:  2015-06-27       Impact factor: 2.031

5.  Anterior chamber depth measured by two methods in myopic and hyperopic phakic IOL implant.

Authors:  M Vetrugno; N Cardascia; L Cardia
Journal:  Br J Ophthalmol       Date:  2000-10       Impact factor: 4.638

6.  Comparison of intraocular lens power prediction using immersion ultrasound and optical biometry with and without formula optimization.

Authors:  Gabor Nemeth; Attila Nagy; Andras Berta; Laszlo Modis
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-04-13       Impact factor: 3.117

7.  Comparison of a new anterior segment optical coherence tomography and Oculus Pentacam for measurement of anterior chamber depth and corneal thickness.

Authors:  Xuepei Li; Yijing Zhou; Charlotte Aimee Young; Aiming Chen; Guangming Jin; Danying Zheng
Journal:  Ann Transl Med       Date:  2020-07

8.  [Individualization of IOL constants for two hydrophobic intraocular lenses. SRK II, SRK/T, Hoffer-Q, Holladay 1 and Haigis formula].

Authors:  A Langenbucher; T Eppig; A Viestenz; B Seitz; G Müllner; U Schönherr
Journal:  Ophthalmologe       Date:  2012-05       Impact factor: 1.059

9.  Prediction of Effective Lens Position Using Multiobjective Evolutionary Algorithm.

Authors:  Akeno Tamaoki; Takashi Kojima; Yoshiki Tanaka; Asato Hasegawa; Tatsushi Kaga; Kazuo Ichikawa; Kiyoshi Tanaka
Journal:  Transl Vis Sci Technol       Date:  2019-06-28       Impact factor: 3.283

10.  Anterior segment biometry using ultrasound biomicroscopy and the Artemis-2 very high frequency ultrasound scanner.

Authors:  Haya M Al-Farhan; Reem N Almutairi
Journal:  Clin Ophthalmol       Date:  2013-01-16
View more