Standardizing constants for ultrasonic biometry, keratometry, and intraocular lens power calculations.

J T Holladay1.   

Abstract

PURPOSE: To provide a method and values that facilitate standardization of constants for ultrasonic biometry, keratometry, and intraocular lens (IOL) power calculations.
SETTING: University of Texas Medical School, Houston, Texas, USA.
METHODS: Keratometry and ultrasonic biometry provide the two measured input variables for the six variable vergence equations used to calculate the appropriate IOL power for a specific patient with a cataract. A review of the literature reflecting the past 156 years of research and development reveals the appropriate index of refraction to be used with the keratometer for net optical corneal power, the location of the principal planes of the cornea, the nominal value for retinal thickness, and the appropriate velocities for ultrasonic measurement of the axial length. The relationship of the thick IOL to the thin IOL is derived along with the physical location of the thick lens. Two methods are described that provide the best IOL constant to be used by a manufacturer to minimize the prediction error for a surgeon using the lens for the first time. The formulas for phakic IOLs and secondary piggyback IOLs are also derived and applied to methods described above for standard IOLs.
RESULTS: Using a standardized net index of refraction of 4/3 for the cornea eliminates a variability of 0.56 diopter (D) in the predicted refraction. Using a standardized 1532 m/s velocity for axial length measurements and adding a value of 0.28 mm reduces the tolerance of axial length measurements to +/-0.03 mm for any length eye. The physical location of the thick IOL's secondary principal plane must be anterior to the thin lens equivalent by approximately the separation of the principal planes of the thick lens. For biconvex poly(methyl methacrylate) IOLs, the separation in the principal planes is approximately 0.10 mm. Using these relationships, the physical position of the thick lens within the eye can be used to confirm the lens constant for any IOL style.
CONCLUSIONS: Standardizing the constants for keratometry, ultrasonic biometry, and IOL power calculations can significantly improve the predictability of refractive outcomes. Back-calculating and physically measuring the position of the lens within the eye can provide surgeons with an initial lens constant known to have a standard error of the mean of +/-0.05 mm (+/-0.10 D). Other parameters such as the cardinal points of a lens, the shape factor, the lens-haptic plane, and the center lens thickness would allow further refinement of IOL power calculations.

Entities:  

Mesh:

Year:  1997        PMID: 9423908     DOI: 10.1016/s0886-3350(97)80115-0

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  33 in total

1.  [Effect of applanation tonometry on precision of biometry measurements].

Authors:  T M Rabsilber; S Bueltmann; M P Holzer; G U Auffarth
Journal:  Ophthalmologe       Date:  2011-01       Impact factor: 1.059

2.  Predictability of intraocular lens power calculation formulae in infantile eyes with unilateral congenital cataract: results from the Infant Aphakia Treatment Study.

Authors:  Deborah K Vanderveen; Rupal H Trivedi; Azhar Nizam; Michael J Lynn; Scott R Lambert
Journal:  Am J Ophthalmol       Date:  2013-09-04       Impact factor: 5.258

3.  Comparison of IOL power calculation formulae for pediatric eyes.

Authors:  V Vasavada; S K Shah; V A Vasavada; A R Vasavada; R H Trivedi; S Srivastava; S A Vasavada
Journal:  Eye (Lond)       Date:  2016-08-05       Impact factor: 3.775

4.  Accuracy of intraocular lens power calculation in paediatric cataract surgery.

Authors:  C Tromans; P M Haigh; S Biswas; I C Lloyd
Journal:  Br J Ophthalmol       Date:  2001-08       Impact factor: 4.638

5.  Comparison of anterior segment parameters and axial lengths of myopic, emmetropic, and hyperopic children.

Authors:  Mehmethan Dogan; Ufuk Elgin; Emine Sen; Kemal Tekin; Pelin Yilmazbas
Journal:  Int Ophthalmol       Date:  2017-12-29       Impact factor: 2.031

6.  Comparison of immersion ultrasound and low coherence reflectometry for ocular biometry in cataract patients.

Authors:  Yan Li; Hong-Xun Li; Yang-Chen Liu; Ya-Tu Guo; Jian-Min Gao; Bin Wu; Nan Zhang; Dong Liu; Xiao-Yong Yuan
Journal:  Int J Ophthalmol       Date:  2018-06-18       Impact factor: 1.779

7.  Image quality in polypseudophakia for extremely short eyes.

Authors:  C C Hull; C S Liu; A Sciscio
Journal:  Br J Ophthalmol       Date:  1999-06       Impact factor: 4.638

8.  Development of a program for toric intraocular lens calculation considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and effective lens position.

Authors:  Youngsub Eom; Dongok Ryu; Dae Wook Kim; Seul Ki Yang; Jong Suk Song; Sug-Whan Kim; Hyo Myung Kim
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-08-19       Impact factor: 3.117

9.  Comparison of preoperative and postoperative ocular biometry in eyes with phakic intraocular lens implantations.

Authors:  Joo Youn Shin; Jae Bum Lee; Kyoung Yul Seo; Eung Kweon Kim; Tae-im Kim
Journal:  Yonsei Med J       Date:  2013-09       Impact factor: 2.759

10.  Clinical efficacy and complications of intraocular lens exchange for opacified intraocular lenses.

Authors:  Seung Mo Kim; Sangkyung Choi
Journal:  Korean J Ophthalmol       Date:  2008-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.