Literature DB >> 9780097

Partial coherence interferometry: a novel approach to biometry in cataract surgery.

W Drexler1, O Findl, R Menapace, G Rainer, C Vass, C K Hitzenberger, A F Fercher.   

Abstract

PURPOSE: To compare biometry performed by an enhanced version of dual beam partial coherence interferometry and applanation ultrasound in a prospective study of 85 cataract eyes to improve refractive outcome of cataract surgery due to a more accurate calculation of intraocular lens power.
METHODS: The SRK II formula using ultrasound biometry data was employed. Three months after surgery, partial coherence interferometry biometry was repeated and refractive outcome was determined. Preoperative partial coherence interferometry biometry data were used to determine the refractive power of the intraocular lenses retrospectively and to calculate the possible refractive outcome.
RESULTS: Precision of partial coherence interferometry biometry was more than 10 times better than that of ultrasound. Therefore, the possible mean absolute error for postoperative refraction achieved with partial coherence interferometry biometry was 0.49 diopters (compared with 0.67 diopters with ultrasound biometry), resulting in an improvement of 27%. Axial eye length measured with the two techniques differed by a mean of 460 microm. The difference in lens thickness measured with partial coherence interferometry and ultrasound significantly correlated with cataract grade. A mean shortening of 120 microm of axial eye length following cataract surgery was also detected by partial coherence interferometry.
CONCLUSIONS: The enhanced version of partial coherence interferometry offers biometry with unprecedented precision (<10 microm) and resolution (approximately 12 microm), therefore improving the refractive outcome in cataract surgery. This noninvasive technique provides a high degree of comfort for the patient, with no need for local anesthesia or pupil dilation and minimized risk of corneal infection.

Entities:  

Mesh:

Year:  1998        PMID: 9780097     DOI: 10.1016/s0002-9394(98)00113-5

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  62 in total

1.  [Effect of applanation tonometry on precision of biometry measurements].

Authors:  T M Rabsilber; S Bueltmann; M P Holzer; G U Auffarth
Journal:  Ophthalmologe       Date:  2011-01       Impact factor: 1.059

2.  IOLMaster biometry: refractive results of 100 consecutive cases.

Authors:  H Eleftheriadis
Journal:  Br J Ophthalmol       Date:  2003-08       Impact factor: 4.638

3.  Misleading axial length measurements with the IOLMaster due to a dense posterior vitreous surface membrane and a macular edema in a diabetic patient.

Authors:  Christoph Fidel Mayer; Navid Ardjomand; Werner Wackernagel; Michaela Velikay-Parel
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-11-03       Impact factor: 3.117

4.  Lens thickness assessment: anterior segment optical coherence tomography versus A-scan ultrasonography.

Authors:  Nikoo Hamzeh; Sasan Moghimi; Golshan Latifi; Massood Mohammadi; Nassim Khatibi; Shan C Lin
Journal:  Int J Ophthalmol       Date:  2015-12-18       Impact factor: 1.779

5.  Effects of combined cataract surgery and trabeculectomy with mitomycin C on ocular dimensions.

Authors:  S K Law; A M Mansury; D Vasudev; J Caprioli
Journal:  Br J Ophthalmol       Date:  2005-08       Impact factor: 4.638

6.  Linear relationship of refractive and biometric lenticular changes during accommodation in emmetropic and myopic eyes.

Authors:  Matthias Bolz; Ana Prinz; Wolfgang Drexler; Oliver Findl
Journal:  Br J Ophthalmol       Date:  2006-10-18       Impact factor: 4.638

7.  Changes in axial length following trabeculectomy and glaucoma drainage device surgery.

Authors:  B A Francis; M Wang; H Lei; L T Du; D S Minckler; R L Green; C Roland
Journal:  Br J Ophthalmol       Date:  2005-01       Impact factor: 4.638

8.  Comparison of anterior segment measurements using rotating Scheimpflug imaging and partial coherence interferometry.

Authors:  Mohammad Soleimani; Hassan Hashemi; Shiva Mehravaran; Mehdi Khabazkhoob; Mohammad Hassan Emamian; Mohammad Shariati; Akbar Fotouhi
Journal:  Int J Ophthalmol       Date:  2013-08-18       Impact factor: 1.779

9.  Factors affecting refractive outcome after cataract surgery in patients with a history of acute primary angle closure.

Authors:  Hyo Seok Lee; Jung Won Park; Sang Woo Park
Journal:  Jpn J Ophthalmol       Date:  2013-10-29       Impact factor: 2.447

10.  Effect of axial length reduction after trabeculectomy on the development of hypotony maculopathy.

Authors:  Yoshiko Matsumoto; Masashi Fujihara; Akiyasu Kanamori; Yuko Yamada; Makoto Nakamura
Journal:  Jpn J Ophthalmol       Date:  2014-03-04       Impact factor: 2.447

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.