Literature DB >> 28026757

Use of Sub-Ensembles and Multi-Template Observers to Evaluate Detection Task Performance for Data That are Not Multivariate Normal.

Xin Li, Abhinav K Jha, Michael Ghaly, Fatma E A Elshahaby, Jonathan M Links, Eric C Frey.   

Abstract

The Hotelling Observer (HO) is widely used to evaluate image quality in medical imaging. However, applying it to data that are not multivariate-normally (MVN) distributed is not optimal. In this paper, we apply two multi-template linear observer strategies to handle such data. First, the entire data ensemble is divided into sub-ensembles that are exactly or approximately MVN and homoscedastic. Next, a different linear observer template is estimated for and applied to each sub-ensemble. The first multi-template strategy, adapted from previous work, applies the HO to each sub-ensemble, calculates the area under the receiver operating characteristics curve (AUC) for each sub-ensemble, and averages the AUCs from all the sub-ensembles. The second strategy applies the Linear Discriminant (LD) to estimate test statistics for each sub-ensemble and calculates a single global AUC using the pooled test statistics from all the sub-ensembles. We show that this second strategy produces the maximum AUC when only shifting of the HO test statistics is allowed. We compared these strategies to the use of a single HO template for the entire data ensemble by applying them to the non-MVN data obtained from reconstructed images of a realistic simulated population of myocardial perfusion SPECT studies with the goal of optimizing the reconstruction parameters. Of the strategies investigated, the multi-template LD strategy yielded the highest AUC for any given set of reconstruction parameters. The optimal reconstruction parameters obtained by the two multi-template strategies were comparable and produced higher AUCs for each sub-ensemble than the single-template HO strategy.

Entities:  

Mesh:

Year:  2016        PMID: 28026757      PMCID: PMC5496770          DOI: 10.1109/TMI.2016.2643684

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  26 in total

1.  Application of task-based measures of image quality to optimization and evaluation of three-dimensional reconstruction-based compensation methods in myocardial perfusion SPECT.

Authors:  Eric C Frey; Karen L Gilland; Benjamin M W Tsui
Journal:  IEEE Trans Med Imaging       Date:  2002-09       Impact factor: 10.048

2.  Ideal-observer performance under signal and background uncertainty.

Authors:  S Park; M A Kupinski; E Clarkson; H H Barrett
Journal:  Inf Process Med Imaging       Date:  2003-07

3.  Fast modelling of the collimator-detector response in Monte Carlo simulation of SPECT imaging using the angular response function.

Authors:  X Song; W P Segars; Y Du; B M W Tsui; E C Frey
Journal:  Phys Med Biol       Date:  2005-04-06       Impact factor: 3.609

4.  A channelized Hotelling observer study of lesion detection in SPECT MAP reconstruction using anatomical priors.

Authors:  S Kulkarni; P Khurd; I Hsiao; L Zhou; G Gindi
Journal:  Phys Med Biol       Date:  2007-05-23       Impact factor: 3.609

5.  Design of a digital phantom population for myocardial perfusion SPECT imaging research.

Authors:  Michael Ghaly; Yong Du; George S K Fung; Benjamin M W Tsui; Jonathan M Links; Eric Frey
Journal:  Phys Med Biol       Date:  2014-05-19       Impact factor: 3.609

6.  Addition of a channel mechanism to the ideal-observer model.

Authors:  K J Myers; H H Barrett
Journal:  J Opt Soc Am A       Date:  1987-12       Impact factor: 2.129

7.  Optimization of energy window and evaluation of scatter compensation methods in myocardial perfusion SPECT using the ideal observer with and without model mismatch and an anthropomorphic model observer.

Authors:  Michael Ghaly; Jonathan M Links; Eric Frey
Journal:  J Med Imaging (Bellingham)       Date:  2015-01

8.  A Clustering Algorithm for Liver Lesion Segmentation of Diffusion-Weighted MR Images.

Authors:  Abhinav K Jha; Jeffrey J Rodríguez; Renu M Stephen; Alison T Stopeck
Journal:  Proc IEEE Southwest Symp Image Anal Interpret       Date:  2010-05-23

9.  Optimization and comparison of simultaneous and separate acquisition protocols for dual isotope myocardial perfusion SPECT.

Authors:  Michael Ghaly; Jonathan M Links; Eric C Frey
Journal:  Phys Med Biol       Date:  2015-06-17       Impact factor: 3.609

10.  Channelized hotelling and human observer correlation for lesion detection in hepatic SPECT imaging.

Authors:  H C Gifford; M A King; D J de Vries; E J Soares
Journal:  J Nucl Med       Date:  2000-03       Impact factor: 10.057

View more
  5 in total

1.  Current pediatric administered activity guidelines for 99m Tc-DMSA SPECT based on patient weight do not provide the same task-based image quality.

Authors:  Ye Li; Shannon O'Reilly; Donika Plyku; S Ted Treves; Frederic Fahey; Yong Du; Xinhua Cao; Briana Sexton-Stallone; Justin Brown; George Sgouros; Wesley E Bolch; Eric C Frey
Journal:  Med Phys       Date:  2019-09-20       Impact factor: 4.071

2.  A physics and learning-based transmission-less attenuation compensation method for SPECT.

Authors:  Zitong Yu; Md Ashequr Rahman; Thomas Schindler; Richard Laforest; Abhinav K Jha
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2021-02-15

3.  Investigating the limited performance of a deep-learning-based SPECT denoising approach: An observer-study-based characterization.

Authors:  Zitong Yu; Md Ashequr Rahman; Abhinav K Jha
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2022-04-04

4.  A projection image database to investigate factors affecting image quality in weight-based dosing: application to pediatric renal SPECT.

Authors:  Ye Li; Shannon O'Reilly; Donika Plyku; S Ted Treves; Yong Du; Frederic Fahey; Xinhua Cao; Abhinav K Jha; George Sgouros; Wesley E Bolch; Eric C Frey
Journal:  Phys Med Biol       Date:  2018-07-09       Impact factor: 3.609

5.  Task-based assessment of binned and list-mode SPECT systems.

Authors:  Md Ashequr Rahman; Abhinav K Jha
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2021-02-15
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.