Literature DB >> 28829044

A comparison of resampling schemes for estimating model observer performance with small ensembles.

Fatma E A Elshahaby1, Abhinav K Jha, Michael Ghaly, Eric C Frey.   

Abstract

In objective assessment of image quality, an ensemble of images is used to compute the 1st and 2nd order statistics of the data. Often, only a finite number of images is available, leading to the issue of statistical variability in numerical observer performance. Resampling-based strategies can help overcome this issue. In this paper, we compared different combinations of resampling schemes (the leave-one-out (LOO) and the half-train/half-test (HT/HT)) and model observers (the conventional channelized Hotelling observer (CHO), channelized linear discriminant (CLD) and channelized quadratic discriminant). Observer performance was quantified by the area under the ROC curve (AUC). For a binary classification task and for each observer, the AUC value for an ensemble size of 2000 samples per class served as a gold standard for that observer. Results indicated that each observer yielded a different performance depending on the ensemble size and the resampling scheme. For a small ensemble size, the combination [CHO, HT/HT] had more accurate rankings than the combination [CHO, LOO]. Using the LOO scheme, the CLD and CHO had similar performance for large ensembles. However, the CLD outperformed the CHO and gave more accurate rankings for smaller ensembles. As the ensemble size decreased, the performance of the [CHO, LOO] combination seriously deteriorated as opposed to the [CLD, LOO] combination. Thus, it might be desirable to use the CLD with the LOO scheme when smaller ensemble size is available.

Entities:  

Mesh:

Year:  2017        PMID: 28829044      PMCID: PMC5944841          DOI: 10.1088/1361-6560/aa807a

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  22 in total

1.  An approach for balancing diagnostic image quality with cancer risk: application to pediatric diagnostic imaging of 99mTc-dimercaptosuccinic acid.

Authors:  George Sgouros; Eric C Frey; Wesley E Bolch; Michael B Wayson; Andres F Abadia; S Ted Treves
Journal:  J Nucl Med       Date:  2011-12       Impact factor: 10.057

2.  Estimation of channelized hotelling observer performance with known class means or known difference of class means.

Authors:  Adam Wunderlich; Frédéric Noo
Journal:  IEEE Trans Med Imaging       Date:  2009-01-19       Impact factor: 10.048

3.  Classifier performance prediction for computer-aided diagnosis using a limited dataset.

Authors:  Berkman Sahiner; Heang-Ping Chan; Lubomir Hadjiiski
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

4.  Design of a digital phantom population for myocardial perfusion SPECT imaging research.

Authors:  Michael Ghaly; Yong Du; George S K Fung; Benjamin M W Tsui; Jonathan M Links; Eric Frey
Journal:  Phys Med Biol       Date:  2014-05-19       Impact factor: 3.609

5.  Collimator performance evaluation for In-111 SPECT using a detection/localization task.

Authors:  Yihuan Lu; Lin Chen; Gene Gindi
Journal:  Phys Med Biol       Date:  2014-02-07       Impact factor: 3.609

6.  Design of a practical model-observer-based image quality assessment method for x-ray computed tomography imaging systems.

Authors:  Hsin-Wu Tseng; Jiahua Fan; Matthew A Kupinski
Journal:  J Med Imaging (Bellingham)       Date:  2016-07-28

7.  Addition of a channel mechanism to the ideal-observer model.

Authors:  K J Myers; H H Barrett
Journal:  J Opt Soc Am A       Date:  1987-12       Impact factor: 2.129

8.  Evaluation of the channelized Hotelling observer with an internal-noise model in a train-test paradigm for cardiac SPECT defect detection.

Authors:  Jovan G Brankov
Journal:  Phys Med Biol       Date:  2013-09-20       Impact factor: 3.609

9.  Optimization of energy window and evaluation of scatter compensation methods in myocardial perfusion SPECT using the ideal observer with and without model mismatch and an anthropomorphic model observer.

Authors:  Michael Ghaly; Jonathan M Links; Eric Frey
Journal:  J Med Imaging (Bellingham)       Date:  2015-01

10.  Channelized hotelling and human observer correlation for lesion detection in hepatic SPECT imaging.

Authors:  H C Gifford; M A King; D J de Vries; E J Soares
Journal:  J Nucl Med       Date:  2000-03       Impact factor: 10.057

View more
  2 in total

1.  A projection image database to investigate factors affecting image quality in weight-based dosing: application to pediatric renal SPECT.

Authors:  Ye Li; Shannon O'Reilly; Donika Plyku; S Ted Treves; Yong Du; Frederic Fahey; Xinhua Cao; Abhinav K Jha; George Sgouros; Wesley E Bolch; Eric C Frey
Journal:  Phys Med Biol       Date:  2018-07-09       Impact factor: 3.609

2.  Optimizing constrained reconstruction in magnetic resonance imaging for signal detection.

Authors:  Angel R Pineda; Hope Miedema; Sajan Goud Lingala; Krishna S Nayak
Journal:  Phys Med Biol       Date:  2021-07-16       Impact factor: 4.174

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.