A new redundancy weighting scheme for nonstationary data for computed tomography.

Katsuyuki Taguchi1, Jochen Cammin1.   

Abstract

PURPOSE: The same projection data (or line integrals) are often measured multiple times, e.g., twice from opposite directions during one gantry rotation. The redundant data must be normalized by applying redundancy weighting such as the halfscan algorithm, which assumes that the noise of the data is uniform. This assumption, however, is not correct when a tube current modulation technique is employed. The variance of line integrals, which is inversely related to the tube current, could vary significantly. The purpose of this work is to improve how the projection data are used during analytical reconstruction when the tube current is modulated during the scan.
METHODS: The authors developed a new redundancy weighting scheme. It not only takes into account the data statistics but also can control how much to weigh the statistics from 100% (αs = 1.0) to 0% (αs = 0.0) by a parameter αs. The proposed weighting scheme reduces to the conventional redundancy weighting scheme when αs = 0.0. The authors evaluated the performance of the proposed scheme using computer simulations targeting at myocardial perfusion CT imaging. The image quality was evaluated in terms of the image noise and halfscan artifacts, and perfusion defect detection performance was evaluated by the positive predictive value (PPV) and the area-under-the-receiver operating characteristic-curve (AUC) value.
RESULTS: Results showed a tradeoff between the image noise and halfscan artifacts. The normalized noise standard deviation was 1.00 with halfscan, 0.89 with αs = 1.0, 0.97 with αs = 0.5, and 1.20 with αs = 0.0 when projections over one rotation (75% of projections are acquired with full dose, 25% with 1/10 of the full dose) are used. The halfscan artifacts were 13.4 Hounsfield unit (HU) with halfscan, 8.2 HU with αs = 1.0, 4.5 HU with αs = 0.5, and 3.1 HU with αs = 0.0. Both the PPVs and AUCs were improved from the halfscan method: PPV, 69.0%-70.6% vs 58.0%, P < 0.003; AUC, 0.935-0.938 vs 0.908, P < 0.003.
CONCLUSIONS: The new redundancy weight allows for decreasing the image noise and controlling the tradeoff between the image noise and artifacts.

Mesh:

Year:  2015        PMID: 25979064      PMCID: PMC4443724          DOI: 10.1118/1.4915954

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  15 in total

1.  An iterative approach to the beam hardening correction in cone beam CT.

Authors:  J Hsieh; R C Molthen; C A Dawson; R H Johnson
Journal:  Med Phys       Date:  2000-01       Impact factor: 4.071

2.  Temporal resolution and the evaluation of candidate algorithms for four-dimensional CT.

Authors:  Katsuyuki Taguchi
Journal:  Med Phys       Date:  2003-04       Impact factor: 4.071

3.  A filtered backprojection MAP algorithm with nonuniform sampling and noise modeling.

Authors:  Gengsheng L Zeng
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

4.  A technical solution to avoid partial scan artifacts in cardiac MDCT.

Authors:  A N Primak; Y Dong; O P Dzyubak; S M Jorgensen; C H McCollough; E L Ritman
Journal:  Med Phys       Date:  2007-12       Impact factor: 4.071

5.  Computed tomography scanning with simultaneous patient translation.

Authors:  C R Crawford; K F King
Journal:  Med Phys       Date:  1990 Nov-Dec       Impact factor: 4.071

6.  Partial scan artifact reduction (PSAR) for the assessment of cardiac perfusion in dynamic phase-correlated CT.

Authors:  Philip Stenner; Bernhard Schmidt; Herbert Bruder; Thomas Allmendinger; Ulrike Haberland; Thomas Flohr; Marc Kachelriess
Journal:  Med Phys       Date:  2009-12       Impact factor: 4.071

7.  Multidetector computed tomography myocardial perfusion imaging during adenosine stress.

Authors:  Richard T George; Caterina Silva; Marco A S Cordeiro; Anthony DiPaula; Douglas R Thompson; William F McCarthy; Takashi Ichihara; Joao A C Lima; Albert C Lardo
Journal:  J Am Coll Cardiol       Date:  2006-06-21       Impact factor: 24.094

8.  Optimal short scan convolution reconstruction for fanbeam CT.

Authors:  D L Parker
Journal:  Med Phys       Date:  1982 Mar-Apr       Impact factor: 4.071

9.  Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice, and cone-beam CT.

Authors:  M Kachelriess; O Watzke; W A Kalender
Journal:  Med Phys       Date:  2001-04       Impact factor: 4.071

10.  Combined CT coronary angiography and stress myocardial perfusion imaging for hemodynamically significant stenoses in patients with suspected coronary artery disease: a comparison with fractional flow reserve.

Authors:  Brian S Ko; James D Cameron; Michael Leung; Ian T Meredith; Darryl P Leong; Paul R Antonis; Marcus Crossett; John Troupis; Richard Harper; Yuvaraj Malaiapan; Sujith K Seneviratne
Journal:  JACC Cardiovasc Imaging       Date:  2012-11
View more
  2 in total

1.  Volumetric CT with sparse detector arrays (and application to Si-strip photon counters).

Authors:  A Sisniega; W Zbijewski; J W Stayman; J Xu; K Taguchi; E Fredenberg; Mats Lundqvist; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2015-11-27       Impact factor: 3.609

2.  Quantitative low-dose rest and stress CT myocardial perfusion imaging with a whole-heart coverage scanner improves functional assessment of coronary artery disease.

Authors:  I-Lun Huang; Ming-Ting Wu; Chin Hu; Guang-Yuan Mar; Ting-Yim Lee; Aaron So
Journal:  Int J Cardiol Heart Vasc       Date:  2019-06-20
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.