Abstract

This paper deals with methods of reducing the total time required to acquire the projection data for a set of contiguous computed tomography (CT) images. Normally during the acquisition of a set of slices, the patient is held stationary during data collection and translated to the next axial location during an interscan delay. We demonstrate using computer simulations and scans of volunteers on a modified scanner how acceptable image quality is achieved if the patient translation time is overlapped with data acquisition. If the concurrent patient translation is ignored, structured artifacts significantly degrade resulting reconstructions. We present a number of weighting schemes for use with the conventional convolution/backprojection algorithm to reduce the structured artifacts through the use of projection modulation using the data from individual and multiple slices. We compare the methods with respect to structured artifacts, noise, resolution and to patient motion. Review of preliminary results by a panel of radiologists indicates that the residual image degradation is tolerable for selected applications when it is critical to acquire more slices in a patient breathing cycle than is possible with conventional scanning.

Entities:  

Mesh:

Year:  1990        PMID: 2280740     DOI: 10.1118/1.596464

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  29 in total

1.  [Current status and future potentials of multislice computed tomography].

Authors:  T Flohr; B Ohnesorge; S Schaller
Journal:  Radiologe       Date:  2004-02       Impact factor: 0.635

2.  Radiation dose reduction in computed tomography: techniques and future perspective.

Authors:  Lifeng Yu; Xin Liu; Shuai Leng; James M Kofler; Juan C Ramirez-Giraldo; Mingliang Qu; Jodie Christner; Joel G Fletcher; Cynthia H McCollough
Journal:  Imaging Med       Date:  2009-10

3.  Noise Reduction for Low-Dose Single-Slice Helical CT Sinograms.

Authors:  Jing Wang; Tianfang Li; Hongbing Lu; Zhengrong Liang
Journal:  IEEE Trans Nucl Sci       Date:  2006-06       Impact factor: 1.679

4.  A filtered backprojection algorithm for triple-source helical cone-beam CT.

Authors:  Jun Zhao; Yannan Jin; Yang Lu; Ge Wang
Journal:  IEEE Trans Med Imaging       Date:  2009-03       Impact factor: 10.048

5.  C-arm based cone-beam CT using a two-concentric-arc source trajectory: system evaluation.

Authors:  Joseph Zambelli; Tingliang Zhuang; Brian E Nett; Cyril Riddell; Barry Belanger; Guang-Hong Chen
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008

6.  Automatic exposure control systems designed to maintain constant image noise: effects on computed tomography dose and noise relative to clinically accepted technique charts.

Authors:  Christopher P Favazza; Lifeng Yu; Shuai Leng; James M Kofler; Cynthia H McCollough
Journal:  J Comput Assist Tomogr       Date:  2015 May-Jun       Impact factor: 1.826

Review 7.  Anniversary paper. Development of x-ray computed tomography: the role of medical physics and AAPM from the 1970s to present.

Authors:  Xiaochuan Pan; Jeffrey Siewerdsen; Patrick J La Riviere; Willi A Kalender
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

8.  Correction for resolution nonuniformities caused by anode angulation in computed tomography.

Authors:  Patrick J La Rivière; Phillip Vargas
Journal:  IEEE Trans Med Imaging       Date:  2008-09       Impact factor: 10.048

9.  Image quality and dose in spiral computed tomography.

Authors:  F R Verdun; R A Meuli; F O Bochud; C Imsand; S Raimondi; P Schnyder; J F Valley
Journal:  Eur Radiol       Date:  1996       Impact factor: 5.315

Review 10.  Imaging scaphoid fractures and nonunions: familiar methods and newer trends.

Authors:  D A Peterson; E A Brandser; C M Steyers
Journal:  Iowa Orthop J       Date:  1996
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.