Optimal short scan convolution reconstruction for fanbeam CT.

D L Parker.   

Abstract

The problem of using a divergent fan beam convolution reconstruction algorithm in conjunction with a minimal complete (180 degrees plus the fan angle) data set is reviewed. It is shown that by proper weighting of the initial data set, image quality essentially equivalent to the quality of reconstructions from 360 degrees data sets is obtained. The constraints on the weights are that the sum of the two weights corresponding to the same line-integral must equal one, in regions of no data the weights must equal zero, and the weights themselves as well as the gradient of the weights must be continuous over the full 360 degrees. After weighting the initial data with weights that satisfy these constraints, image reconstruction can be conveniently achieved by using the standard (hardwired if available) convolver and backprojector of the specific scanner.

Mesh:

Year:  1982        PMID: 7087912     DOI: 10.1118/1.595078

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  80 in total

1.  Regularization designs for uniform spatial resolution and noise properties in statistical image reconstruction for 3-D X-ray CT.

Authors:  Jang Hwan Cho; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2014-10-28       Impact factor: 10.048

2.  A strategy to decrease partial scan reconstruction artifacts in myocardial perfusion CT: phantom and in vivo evaluation.

Authors:  Juan C Ramirez-Giraldo; Lifeng Yu; Birgit Kantor; Erik L Ritman; Cynthia H McCollough
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

3.  Development, implementation and evaluation of a dedicated metal artefact reduction method for interventional flat-detector CT.

Authors:  D Prell; W A Kalender; Y Kyriakou
Journal:  Br J Radiol       Date:  2010-09-21       Impact factor: 3.039

4.  Design of a compensating bolus by use of exhalation CT data for covering residual motion in respiratory-gated charged-particle lung therapy: four-dimensional carbon beam dose calculation.

Authors:  Shinichiro Mori; Hiroshi Asakura; Shuhei Komatsu; Tomoyasu Yashiro; Motoki Kumagai; Susumu Kandatsu; Masayuki Baba; Masahiro Endo
Journal:  Radiol Phys Technol       Date:  2007-11-27

5.  Volumetric tracking tool using four-dimensional CT for image guided-radiation therapy.

Authors:  Rie Tanaka; Shinichiro Mori; Masahiro Endo; Shigeru Sanada
Journal:  Radiol Phys Technol       Date:  2007-11-13

6.  Multibeam field emission x-ray system with half-scan reconstruction algorithm.

Authors:  Yang Lu; Hengyong Yu; Guohua Cao; Jun Zhao; Ge Wang; Otto Zhou
Journal:  Med Phys       Date:  2010-07       Impact factor: 4.071

7.  Replacing vascular corrosion casting by in vivo micro-CT imaging for building 3D cardiovascular models in mice.

Authors:  Bert Vandeghinste; Bram Trachet; Marjolijn Renard; Christophe Casteleyn; Steven Staelens; Bart Loeys; Patrick Segers; Stefaan Vandenberghe
Journal:  Mol Imaging Biol       Date:  2011-02       Impact factor: 3.488

8.  Anatomical background and generalized detectability in tomosynthesis and cone-beam CT.

Authors:  G J Gang; D J Tward; J Lee; J H Siewerdsen
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

9.  Contrast-enhanced angiographic cone-beam CT of cerebrovascular stents: experimental optimization and clinical application.

Authors:  N V Patel; M J Gounis; A K Wakhloo; N Noordhoek; J Blijd; D Babic; D Takhtani; S-K Lee; A Norbash
Journal:  AJNR Am J Neuroradiol       Date:  2010-10-21       Impact factor: 3.825

10.  Filtered Backprojection Reconstruction with Depth-Dependent Filtering.

Authors:  Frank Dennerlein; Holger Kunze; Frédéric Noo
Journal:  Tsinghua Sci Technol       Date:  2010-02       Impact factor: 2.016