OBJECTIVES: The purpose of this study is to validate the accuracy of multidetector computed tomography (MDCT) to measure differences in regional myocardial perfusion during adenosine stress in a canine model of left anterior descending (LAD) artery stenosis, during first-pass, contrast-enhanced helical MDCT. BACKGROUND: Myocardial perfusion imaging by MDCT may have significant implications in the diagnosis and treatment of coronary artery disease. METHODS: Eight dogs were prepared with a LAD stenosis, and contrast-enhanced MDCT imaging was performed 5 min into adenosine infusion (0.14 to 0.21 mg/kg/min). Images were analyzed using a semiautomated approach to define the regional signal density (SD) ratio (myocardial SD/left ventricular blood pool SD) in stenosed and remote territories, and then compared with microsphere myocardial blood flow (MBF) measurements. RESULTS: Mean MBF in stenosed versus remote territories was 1.37 +/- 0.46 ml/g/min and 1.29 +/- 0.48 ml/g/min at baseline (p = NS) and 2.54 +/- 0.93 ml/g/min and 8.94 +/- 5.74 ml/g/min during adenosine infusion, respectively (p < 0.05). Myocardial SD was 92.3 +/- 39.5 HU in stenosed versus 180.4 +/- 41.9 HU in remote territories (p < 0.001). There was a significant linear association of the SD ratio with MBF in the stenosed territory (R = 0.98, p = 0.001) and between regional myocardial SD ratio and MBF <8 ml/g/min, slope = 0.035, SE = 0.007, p < 0.0001. Overall, there was a significant non-linear relationship over the range of flows studied (LR chi-square [2 degrees of freedom] = 31.8, p < 0.0001). CONCLUSIONS: Adenosine-augmented MDCT myocardial perfusion imaging provides semiquantitative measurements of myocardial perfusion during first-pass MDCT imaging in a canine model of LAD stenosis.
OBJECTIVES: The purpose of this study is to validate the accuracy of multidetector computed tomography (MDCT) to measure differences in regional myocardial perfusion during adenosine stress in a canine model of left anterior descending (LAD) artery stenosis, during first-pass, contrast-enhanced helical MDCT. BACKGROUND: Myocardial perfusion imaging by MDCT may have significant implications in the diagnosis and treatment of coronary artery disease. METHODS: Eight dogs were prepared with a LAD stenosis, and contrast-enhanced MDCT imaging was performed 5 min into adenosine infusion (0.14 to 0.21 mg/kg/min). Images were analyzed using a semiautomated approach to define the regional signal density (SD) ratio (myocardial SD/left ventricular blood pool SD) in stenosed and remote territories, and then compared with microsphere myocardial blood flow (MBF) measurements. RESULTS: Mean MBF in stenosed versus remote territories was 1.37 +/- 0.46 ml/g/min and 1.29 +/- 0.48 ml/g/min at baseline (p = NS) and 2.54 +/- 0.93 ml/g/min and 8.94 +/- 5.74 ml/g/min during adenosine infusion, respectively (p < 0.05). Myocardial SD was 92.3 +/- 39.5 HU in stenosed versus 180.4 +/- 41.9 HU in remote territories (p < 0.001). There was a significant linear association of the SD ratio with MBF in the stenosed territory (R = 0.98, p = 0.001) and between regional myocardial SD ratio and MBF <8 ml/g/min, slope = 0.035, SE = 0.007, p < 0.0001. Overall, there was a significant non-linear relationship over the range of flows studied (LR chi-square [2 degrees of freedom] = 31.8, p < 0.0001). CONCLUSIONS:Adenosine-augmented MDCT myocardial perfusion imaging provides semiquantitative measurements of myocardial perfusion during first-pass MDCT imaging in a canine model of LAD stenosis.
Authors: Andrea L Vavere; Gregory G Simon; Richard T George; Carlos E Rochitte; Andrew E Arai; Julie M Miller; Marcello Di Carli; Armin Arbab-Zadeh; Armin A Zadeh; Marc Dewey; Hiroyuki Niinuma; Roger Laham; Frank J Rybicki; Joanne D Schuijf; Narinder Paul; John Hoe; Sachio Kuribyashi; Hajime Sakuma; Cesar Nomura; Tan Swee Yaw; Klaus F Kofoed; Kunihiro Yoshioka; Melvin E Clouse; Jeffrey Brinker; Christopher Cox; Joao A C Lima Journal: J Cardiovasc Comput Tomogr Date: 2011-11-12
Authors: J Tobias Kühl; Jesper J Linde; Andreas Fuchs; Thomas S Kristensen; Henning Kelbæk; Richard T George; Jens D Hove; Klaus Fuglsang Kofoed Journal: Int J Cardiovasc Imaging Date: 2011-12-06 Impact factor: 2.357
Authors: Fabian Bamberg; Ernst Klotz; Thomas Flohr; Alexander Becker; Christoph R Becker; Bernhard Schmidt; Bernd J Wintersperger; Maximilian F Reiser; Konstantin Nikolaou Journal: Eur Radiol Date: 2010-03-24 Impact factor: 5.315
Authors: E Maffei; C Martini; S De Crescenzo; T Arcadi; A Clemente; E Capuano; A Rossi; R Malagò; N Mollet; A Weustink; C Tedeschi; L La Grutta; S Seitun; A Igoren Guaricci; F Cademartiri Journal: Radiol Med Date: 2010-06-23 Impact factor: 3.469