Literature DB >> 25940706

Velocity-selective magnetization-prepared non-contrast-enhanced cerebral MR angiography at 3 Tesla: Improved immunity to B0/B1 inhomogeneity.

Qin Qin1,2, Taehoon Shin3, Michael Schär1, Hua Guo4, Hanwei Chen5, Ye Qiao1.   

Abstract

PURPOSE: To develop a Fourier-transform based velocity-selective (VS) pulse train that offers improved robustness to B0/B1 inhomogeneity for non-contrast-enhanced cerebral MR angiography (MRA) at 3 Tesla (T).
METHODS: VS pulse train I and II with different saturation bands are proposed to incorporate paired and phase cycled refocusing pulses. Their sensitivity to B0/B1 inhomogeneity was estimated through simulation and compared with a single refocused VS pulse train. The implementation was compared to standard time of flight (TOF) among eight healthy subjects.
RESULTS: In contrast to single refocused VS pulse train, the simulated VS profiles from proposed pulse trains indicate much improved immunity to field inhomogeneity in the brain at 3T. Successive application of two identical VS pulse trains yields a better suppression of static tissue at the cost of 20 ∼ 30% signal loss within large vessels. Average relative contrast ratios of major cerebral arterial segments applying both pulse train I and II with two preparations are 0.81 ± 0.06 and 0.81 ± 0.05, respectively, significantly higher than 0.67 ± 0.07 of TOF-MRA. VS MRA, in particular, the pulse train II with the narrower saturation band, depicts more small vessels with slower flow.
CONCLUSION: VS magnetization-prepared cerebral MRA was demonstrated among normal subjects on a 3T scanner.
© 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  cerebral MRA; non-contrast-enhanced MRA; velocity-selective pulse train

Mesh:

Year:  2015        PMID: 25940706      PMCID: PMC4630207          DOI: 10.1002/mrm.25764

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  47 in total

1.  Non-contrast-enhanced MR angiography using 3D ECG-synchronized half-Fourier fast spin echo.

Authors:  M Miyazaki; S Sugiura; F Tateishi; H Wada; Y Kassai; H Abe
Journal:  J Magn Reson Imaging       Date:  2000-11       Impact factor: 4.813

Review 2.  Vascular disorders--magnetic resonance angiography: brain vessels.

Authors:  Norbert G Campeau; John Huston
Journal:  Neuroimaging Clin N Am       Date:  2012-03-29       Impact factor: 2.264

3.  Saturated double-angle method for rapid B1+ mapping.

Authors:  Charles H Cunningham; John M Pauly; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2006-06       Impact factor: 4.668

4.  Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters.

Authors:  Olaf Dietrich; José G Raya; Scott B Reeder; Maximilian F Reiser; Stefan O Schoenberg
Journal:  J Magn Reson Imaging       Date:  2007-08       Impact factor: 4.813

5.  Non-contrast-enhanced four-dimensional (4D) intracranial MR angiography: a feasibility study.

Authors:  Xiaoming Bi; Peter Weale; Peter Schmitt; Sven Zuehlsdorff; Renate Jerecic
Journal:  Magn Reson Med       Date:  2010-03       Impact factor: 4.668

Review 6.  Non-contrast enhanced MR angiography: physical principles.

Authors:  Andrew J Wheaton; Mitsue Miyazaki
Journal:  J Magn Reson Imaging       Date:  2012-08       Impact factor: 4.813

7.  MR imaging of motion with spatial modulation of magnetization.

Authors:  L Axel; L Dougherty
Journal:  Radiology       Date:  1989-06       Impact factor: 11.105

8.  MR angiography by selective inversion recovery.

Authors:  D G Nishimura; A Macovski; J M Pauly; S M Conolly
Journal:  Magn Reson Med       Date:  1987-02       Impact factor: 4.668

9.  Determination of whole-brain oxygen extraction fractions by fast measurement of blood T(2) in the jugular vein.

Authors:  Qin Qin; Ksenija Grgac; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2010-11-30       Impact factor: 4.668

10.  Quiescent-interval single-shot unenhanced magnetic resonance angiography of peripheral vascular disease: Technical considerations and clinical feasibility.

Authors:  Robert R Edelman; John J Sheehan; Eugene Dunkle; Nancy Schindler; James Carr; Ioannis Koktzoglou
Journal:  Magn Reson Med       Date:  2010-04       Impact factor: 4.668

View more
  23 in total

Review 1.  Noncontrast MR angiography: An update.

Authors:  Robert R Edelman; Ioannis Koktzoglou
Journal:  J Magn Reson Imaging       Date:  2018-12-19       Impact factor: 4.813

2.  Cerebral blood volume mapping using Fourier-transform-based velocity-selective saturation pulse trains.

Authors:  Qin Qin; Yaoming Qu; Wenbo Li; Dapeng Liu; Taehoon Shin; Yansong Zhao; Doris D Lin; Peter C M van Zijl; Zhibo Wen
Journal:  Magn Reson Med       Date:  2019-02-08       Impact factor: 4.668

3.  Non-contrast-enhanced abdominal MRA at 3 T using velocity-selective pulse trains.

Authors:  Dan Zhu; Wenbo Li; Dapeng Liu; Guanshu Liu; Yigang Pei; Taehoon Shin; Farzad Sedaghat; Qin Qin
Journal:  Magn Reson Med       Date:  2020-02-04       Impact factor: 4.668

4.  Improved velocity-selective-inversion arterial spin labeling for cerebral blood flow mapping with 3D acquisition.

Authors:  Dapeng Liu; Feng Xu; Wenbo Li; Peter C van Zijl; Doris D Lin; Qin Qin
Journal:  Magn Reson Med       Date:  2020-05-13       Impact factor: 4.668

5.  Velocity-selective magnetization-prepared non-contrast-enhanced cerebral MR angiography at 3 Tesla: Improved immunity to B0/B1 inhomogeneity.

Authors:  Qin Qin; Taehoon Shin; Michael Schär; Hua Guo; Hanwei Chen; Ye Qiao
Journal:  Magn Reson Med       Date:  2015-05-02       Impact factor: 4.668

6.  Characterization and suppression of stripe artifact in velocity-selective magnetization-prepared unenhanced MR angiography.

Authors:  Taehoon Shin; Qin Qin
Journal:  Magn Reson Med       Date:  2018-03-13       Impact factor: 4.668

7.  Whole-brain arteriography and venography: Using improved velocity-selective saturation pulse trains.

Authors:  Wenbo Li; Feng Xu; Michael Schär; Jing Liu; Taehoon Shin; Yansong Zhao; Peter C M van Zijl; Bruce A Wasserman; Ye Qiao; Qin Qin
Journal:  Magn Reson Med       Date:  2017-08-10       Impact factor: 4.668

8.  Identification and reduction of image artifacts in non-contrast-enhanced velocity-selective peripheral angiography at 3T.

Authors:  Taehoon Shin; Qin Qin; Jang-Yeon Park; Robert S Crawford; Sanjay Rajagopalan
Journal:  Magn Reson Med       Date:  2015-08-26       Impact factor: 4.668

9.  Improved velocity-selective labeling pulses for myocardial ASL.

Authors:  Vanessa Landes; Ahsan Javed; Terrence Jao; Qin Qin; Krishna Nayak
Journal:  Magn Reson Med       Date:  2020-03-15       Impact factor: 4.668

10.  Velocity-selective-inversion prepared arterial spin labeling.

Authors:  Qin Qin; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2015-10-28       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.