Literature DB >> 21264936

Determination of whole-brain oxygen extraction fractions by fast measurement of blood T(2) in the jugular vein.

Qin Qin1, Ksenija Grgac, Peter C M van Zijl.   

Abstract

The oxygen extraction fraction of the brain reports on the balance between oxygen delivery and consumption and can be used to assess deviations in physiological homeostasis. This is relevant clinically as well as for calibrating blood oxygen level-dependent functional MRI responses. Oxygen extraction fraction is reflected in the arteriovenous difference in oxygen saturation fraction (Y(v) - Y(a) ), which can be determined from venous T(2) values when arterial oxygenation is known. A pulse sequence is presented that allows rapid measurement (<1 min) of blood T(2) s in the internal jugular vein. The technique combines slice-saturation and blood inflow to attain high signal-to-noise ratio in blood and minimal contamination from tissue. The sequence is sensitized to T(2) using a nonselective Carr-Purcell-Meiboom-Gill T(2) preparation directly after slice saturation. Fast scanning (pulse repetition time of about 2 sec) is possible by using a nonselective saturation directly after acquisition to rapidly achieve steady-state longitudinal magnetization. The venous T(2) (for 10 msec Carr-Purcell-Meiboom-Gill interecho time) for normal volunteers was 62.4 ± 6.1 msec (n = 20). A calibration curve relating T(2) to blood oxygenation was established using a blood perfusion phantom. Using this calibration, a whole-brain oxygen extraction fraction of 0.37 ± 0.04 was determined (n = 20), in excellent agreement with literature values.
Copyright © 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21264936      PMCID: PMC3052781          DOI: 10.1002/mrm.22556

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  39 in total

1.  MR susceptometry for measuring global brain oxygen extraction.

Authors:  María A Fernández-Seara; Aranee Techawiboonwong; John A Detre; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2006-05       Impact factor: 4.668

2.  Quantitative BOLD: mapping of human cerebral deoxygenated blood volume and oxygen extraction fraction: default state.

Authors:  Xiang He; Dmitriy A Yablonskiy
Journal:  Magn Reson Med       Date:  2007-01       Impact factor: 4.668

3.  1991 I.I. Rabi Award. Estimating oxygen saturation of blood in vivo with MR imaging at 1.5 T.

Authors:  G A Wright; B S Hu; A Macovski
Journal:  J Magn Reson Imaging       Date:  1991 May-Jun       Impact factor: 4.813

4.  Coronary venous oximetry using MRI.

Authors:  W D Foltz; N Merchant; E Downar; J A Stainsby; G A Wright
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

5.  Nonoxidative glucose consumption during focal physiologic neural activity.

Authors:  P T Fox; M E Raichle; M A Mintun; C Dence
Journal:  Science       Date:  1988-07-22       Impact factor: 47.728

6.  Oxygenation dependence of the transverse relaxation time of water protons in whole blood at high field.

Authors:  K R Thulborn; J C Waterton; P M Matthews; G K Radda
Journal:  Biochim Biophys Acta       Date:  1982-02-02

7.  Carotid artery velocity patterns in normal and stenotic vessels.

Authors:  W M Blackshear; D J Phillips; P M Chikos; J D Harley; B L Thiele; D E Strandness
Journal:  Stroke       Date:  1980 Jan-Feb       Impact factor: 7.914

Review 8.  A model for the coupling between cerebral blood flow and oxygen metabolism during neural stimulation.

Authors:  R B Buxton; L R Frank
Journal:  J Cereb Blood Flow Metab       Date:  1997-01       Impact factor: 6.200

9.  Baseline blood oxygenation modulates response amplitude: Physiologic basis for intersubject variations in functional MRI signals.

Authors:  Hanzhang Lu; Chenguang Zhao; Yulin Ge; Kelly Lewis-Amezcua
Journal:  Magn Reson Med       Date:  2008-08       Impact factor: 4.668

10.  Quantitative evaluation of oxygenation in venous vessels using T2-Relaxation-Under-Spin-Tagging MRI.

Authors:  Hanzhang Lu; Yulin Ge
Journal:  Magn Reson Med       Date:  2008-08       Impact factor: 4.668

View more
  44 in total

1.  Blood longitudinal (T1) and transverse (T2) relaxation time constants at 11.7 Tesla.

Authors:  Ai-Ling Lin; Qin Qin; Xia Zhao; Timothy Q Duong
Journal:  MAGMA       Date:  2011-11-10       Impact factor: 2.310

2.  d-glucose weighted chemical exchange saturation transfer (glucoCEST)-based dynamic glucose enhanced (DGE) MRI at 3T: early experience in healthy volunteers and brain tumor patients.

Authors:  Xiang Xu; Akansha Ashvani Sehgal; Nirbhay N Yadav; John Laterra; Lindsay Blair; Jaishri Blakeley; Anina Seidemo; Jennifer M Coughlin; Martin G Pomper; Linda Knutsson; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2019-12-24       Impact factor: 4.668

3.  Physiological origin for the BOLD poststimulus undershoot in human brain: vascular compliance versus oxygen metabolism.

Authors:  Jun Hua; Robert D Stevens; Alan J Huang; James J Pekar; Peter C M van Zijl
Journal:  J Cereb Blood Flow Metab       Date:  2011-04-06       Impact factor: 6.200

4.  Correction and optimization of a T2-based approach to map blood oxygenation in small cerebral veins.

Authors:  Lisa C Krishnamurthy; Deng Mao; Kevin S King; Hanzhang Lu
Journal:  Magn Reson Med       Date:  2015-04-04       Impact factor: 4.668

5.  Multisite evaluations of a T2 -relaxation-under-spin-tagging (TRUST) MRI technique to measure brain oxygenation.

Authors:  Peiying Liu; Ivan Dimitrov; Trevor Andrews; David E Crane; Jacinda K Dariotis; John Desmond; Julie Dumas; Guillaume Gilbert; Anand Kumar; Bradley J Maclntosh; Alan Tucholka; Shaolin Yang; Guanghua Xiao; Hanzhang Lu
Journal:  Magn Reson Med       Date:  2015-04-04       Impact factor: 4.668

6.  Quantification of whole-brain oxygenation extraction fraction and cerebral metabolic rate of oxygen consumption in adults with sickle cell anemia using individual T2 -based oxygenation calibrations.

Authors:  Wenbo Li; Xiang Xu; Peiying Liu; John J Strouse; James F Casella; Hanzhang Lu; Peter C M van Zijl; Qin Qin
Journal:  Magn Reson Med       Date:  2019-09-04       Impact factor: 4.668

Review 7.  Imaging the physiological evolution of the ischemic penumbra in acute ischemic stroke.

Authors:  Richard Leigh; Linda Knutsson; Jinyuan Zhou; Peter Cm van Zijl
Journal:  J Cereb Blood Flow Metab       Date:  2017-03-27       Impact factor: 6.200

8.  Cerebral blood volume mapping using Fourier-transform-based velocity-selective saturation pulse trains.

Authors:  Qin Qin; Yaoming Qu; Wenbo Li; Dapeng Liu; Taehoon Shin; Yansong Zhao; Doris D Lin; Peter C M van Zijl; Zhibo Wen
Journal:  Magn Reson Med       Date:  2019-02-08       Impact factor: 4.668

9.  Quantitative theory for the transverse relaxation time of blood water.

Authors:  Wenbo Li; Peter C M van Zijl
Journal:  NMR Biomed       Date:  2020-02-05       Impact factor: 4.044

10.  On-resonance variable delay multipulse scheme for imaging of fast-exchanging protons and semisolid macromolecules.

Authors:  Jiadi Xu; Kannie W Y Chan; Xiang Xu; Nirbhay Yadav; Guanshu Liu; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2016-02-22       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.