Literature DB >> 20187191

Non-contrast-enhanced four-dimensional (4D) intracranial MR angiography: a feasibility study.

Xiaoming Bi1, Peter Weale, Peter Schmitt, Sven Zuehlsdorff, Renate Jerecic.   

Abstract

T(1)-shortening contrast agents have been widely used in time-resolved magnetic resonance angiography. To match imaging data acquisition with the short time period of the first pass of contrast agent, temporal resolution and/or spatial resolution have to be compromised in many cases. In this study, a novel non-contrast-enhanced technique was developed for time-resolved magnetic resonance angiography. Alternating magnetization preparation was applied in two consecutive acquisitions of each measurement to eliminate the need for contrast media. Without the constraint of contrast media kinetics, temporal resolution is drastically improved from the order of a second as in conventional contrast-enhanced approach to tens of milliseconds (50.9 msec) in this study, without compromising spatial resolution. Initial results from volunteer studies demonstrate the feasibility of this method to depict anatomic structure and dynamic filling of main vessels in the head. (c) 2010 Wiley-Liss, Inc.

Mesh:

Substances:

Year:  2010        PMID: 20187191     DOI: 10.1002/mrm.22220

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  22 in total

1.  Noncontrast-enhanced three-dimensional (3D) intracranial MR angiography using pseudocontinuous arterial spin labeling and accelerated 3D radial acquisition.

Authors:  Huimin Wu; Walter F Block; Patrick A Turski; Charles A Mistretta; Kevin M Johnson
Journal:  Magn Reson Med       Date:  2012-04-24       Impact factor: 4.668

2.  Noncontrast dynamic 3D intracranial MR angiography using pseudo-continuous arterial spin labeling (PCASL) and accelerated 3D radial acquisition.

Authors:  Huimin Wu; Walter F Block; Patrick A Turski; Charles A Mistretta; David J Rusinak; Yijing Wu; Kevin M Johnson
Journal:  J Magn Reson Imaging       Date:  2013-10-15       Impact factor: 4.813

Review 3.  Noncontrast MR angiography: An update.

Authors:  Robert R Edelman; Ioannis Koktzoglou
Journal:  J Magn Reson Imaging       Date:  2018-12-19       Impact factor: 4.813

4.  Computer-assisted analysis of human upper arm flexion by 4D-visualization based on MRI.

Authors:  Cornelia Kober; Luigi Gallo; Hans-Florian Zeilhofer; Robert Alexander Sader
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-02-25       Impact factor: 2.924

5.  Nonenhanced ECG-gated time-resolved 4D steady-state free precession (SSFP) MR angiography (MRA) for assessment of cerebral collateral flow: comparison with digital subtraction angiography (DSA).

Authors:  Rotem Shlomo Lanzman; Patric Kröpil; Peter Schmitt; Xiaoming Bi; Michael Gliem; Falk R Miese; Daniel Hänggi; Marcel Kamp; Axel Scherer; Bernd Turowski; Dirk Blondin
Journal:  Eur Radiol       Date:  2011-01-12       Impact factor: 5.315

6.  Vessel-selective, non-contrast enhanced, time-resolved MR angiography with vessel-selective arterial spin labeling technique (CINEMA-SELECT) in intracranial arteries.

Authors:  Masanobu Nakamura; Masami Yoneyama; Takashi Tabuchi; Atsushi Takemura; Makoto Obara; Satoshi Tatsuno; Seishi Sawano
Journal:  Radiol Phys Technol       Date:  2013-03-10

7.  Optimization of post-label delay in single-phase arterial spin labeling (ASL) using multi-phase ASL in four-dimensional magnetic resonance angiography.

Authors:  Tsuyoshi Oshita; Hidetake Yabuuchi; Masanobu Osame
Journal:  Neuroradiol J       Date:  2019-04-11

8.  Noncontrast enhanced four-dimensional dynamic MRA with golden angle radial acquisition and K-space weighted image contrast (KWIC) reconstruction.

Authors:  Hee Kwon Song; Lirong Yan; Robert X Smith; Yiqun Xue; Stanislas Rapacchi; Subashini Srinivasan; Daniel B Ennis; Peng Hu; Nader Pouratian; Danny J J Wang
Journal:  Magn Reson Med       Date:  2013-12-12       Impact factor: 4.668

9.  Non-contrast-enhanced 4D MR angiography with STAR spin labeling and variable flip angle sampling: a feasibility study for the assessment of Dural Arteriovenous Fistula.

Authors:  Jinhee Jang; Peter Schmitt; Bom-yi Kim; Hyun Seok Choi; So-Lyung Jung; Kook-Jin Ahn; Inseong Kim; Munyoung Paek; Bum-soo Kim
Journal:  Neuroradiology       Date:  2014-02-14       Impact factor: 2.804

10.  Time-resolved noncontrast enhanced 4-D dynamic magnetic resonance angiography using multibolus TrueFISP-based spin tagging with alternating radiofrequency (TrueSTAR).

Authors:  Lirong Yan; Noriko Salamon; Danny J J Wang
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.