Qin Qin1,2, Yaoming Qu3, Wenbo Li1,2, Dapeng Liu1,2, Taehoon Shin4,5, Yansong Zhao6, Doris D Lin1, Peter C M van Zijl1,2, Zhibo Wen3. 1. The Russell H. Morgan Department of Radiology and Radiological Science, Division of MR Research, Johns Hopkins University School of Medicine, Baltimore, Maryland. 2. F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland. 3. Department of Radiology, Zhujiang Hospital, Southern Medical University, Guangzhou, China. 4. Division of Mechanical and Biomedical Engineering, Ewha Womans University, Seoul, South Korea. 5. Department of Medicine, Case Western Reserve University, Cleveland, Ohio. 6. Philips Healthcare, Cleveland, Ohio.
Abstract
PURPOSE: Velocity-selective saturation (VSS) pulse trains provide a viable alternative to the spatially selective methods for measuring cerebral blood volume (CBV) by reducing the sensitivity to arterial transit time. This study is to compare the Fourier-transform-based velocity-selective saturation (FT-VSS) pulse trains with the conventional flow-dephasing VSS techniques for CBV quantification. METHODS: The proposed FT-VSS label and control modules were compared with VSS pulse trains utilizing double refocused hyperbolic tangent (DRHT) and 8-segment B1-insensitive rotation (BIR-8). This was done using both numerical simulations and phantom studies to evaluate their sensitivities to gradient imperfections such as eddy currents. DRHT, BIR-8, and FT-VSS prepared CBV mapping was further compared for velocity-encoding gradients along 3 orthogonal directions in healthy subjects at 3T. RESULTS: The phantom studies exhibited more consistent immunity to gradient imperfections for the utilized FT-VSS pulse trains. Compared to DRHT and BIR-8, FT-VSS delivered more robust CBV results across the 3 VS encoding directions with significantly reduced artifacts along the superior-inferior direction and improved temporal signal-to-noise ratio (SNR) values. Average CBV values obtained from FT-VSS based sequences were 5.3 mL/100 g for gray matter and 2.3 mL/100 g for white matter, comparable to literature expectations. CONCLUSION: Absolute CBV quantification utilizing advanced FT-VSS pulse trains had several advantages over the existing approaches using flow-dephasing VSS modules. A greater immunity to gradient imperfections and the concurrent tissue background suppression of FT-VSS pulse trains enabled more robust CBV measurements and higher SNR than the conventional VSS pulse trains.
PURPOSE: Velocity-selective saturation (VSS) pulse trains provide a viable alternative to the spatially selective methods for measuring cerebral blood volume (CBV) by reducing the sensitivity to arterial transit time. This study is to compare the Fourier-transform-based velocity-selective saturation (FT-VSS) pulse trains with the conventional flow-dephasing VSS techniques for CBV quantification. METHODS: The proposed FT-VSS label and control modules were compared with VSS pulse trains utilizing double refocused hyperbolic tangent (DRHT) and 8-segment B1-insensitive rotation (BIR-8). This was done using both numerical simulations and phantom studies to evaluate their sensitivities to gradient imperfections such as eddy currents. DRHT, BIR-8, and FT-VSS prepared CBV mapping was further compared for velocity-encoding gradients along 3 orthogonal directions in healthy subjects at 3T. RESULTS: The phantom studies exhibited more consistent immunity to gradient imperfections for the utilized FT-VSS pulse trains. Compared to DRHT and BIR-8, FT-VSS delivered more robust CBV results across the 3 VS encoding directions with significantly reduced artifacts along the superior-inferior direction and improved temporal signal-to-noise ratio (SNR) values. Average CBV values obtained from FT-VSS based sequences were 5.3 mL/100 g for gray matter and 2.3 mL/100 g for white matter, comparable to literature expectations. CONCLUSION: Absolute CBV quantification utilizing advanced FT-VSS pulse trains had several advantages over the existing approaches using flow-dephasing VSS modules. A greater immunity to gradient imperfections and the concurrent tissue background suppression of FT-VSS pulse trains enabled more robust CBV measurements and higher SNR than the conventional VSS pulse trains.
Authors: James H Holmes; Mu-Lan Jen; Laura B Eisenmenger; Tilman Schubert; Patrick A Turski; Kevin M Johnson Journal: Magn Reson Med Date: 2021-02-21 Impact factor: 3.737