Literature DB >> 11050650

Non-contrast-enhanced MR angiography using 3D ECG-synchronized half-Fourier fast spin echo.

M Miyazaki1, S Sugiura, F Tateishi, H Wada, Y Kassai, H Abe.   

Abstract

A non-contrast-enhanced three-dimensional (3D) magnetic resonance angiography (MRA) technique, which acquires images in a reasonably short scanning time and requires no contrast agent, is developed. An electrocardiographically (ECG) synchronized 3D half-Fourier fast spin-echo (FSE) technique with an appropriate ECG delay time for every slice encoding in 3D terms was used to examine the thoracic and iliac regions in 16 healthy volunteers at both 0.5 and 1.5 T. Prior to each 3D fresh blood imaging (FBI) experiment, an ECG preparation (ECG-prep) scan was acquired, and an appropriate ECG triggering time was selected for 3D FBI acquisition to optimize visualization of the vessel of interest. In the thoracic and abdominal regions, good-quality 3D MRA images were obtained. Furthermore, the weighted subtraction of two images in different phases provides contrast enhancement between arteries and veins.

Mesh:

Year:  2000        PMID: 11050650     DOI: 10.1002/1522-2586(200011)12:5<776::aid-jmri17>3.0.co;2-x

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  49 in total

1.  Nonenhanced methods for lower-extremity MRA: a phantom study examining the effects of stenosis and pathologic flow waveforms at 1.5T.

Authors:  Erik J Offerman; Philip A Hodnett; Robert R Edelman; Ioannis Koktzoglou
Journal:  J Magn Reson Imaging       Date:  2011-02       Impact factor: 4.813

2.  Magnetic resonance angiography (MRA) of the calf station at 3.0 T: intraindividual comparison of non-enhanced ECG-gated flow-dependent MRA, continuous table movement MRA and time-resolved MRA.

Authors:  Stefan Haneder; Ulrike I Attenberger; Philipp Riffel; Thomas Henzler; Stefan O Schoenberg; Henrik J Michaely
Journal:  Eur Radiol       Date:  2011-01-28       Impact factor: 5.315

3.  Renal arteries: isotropic, high-spatial-resolution, unenhanced MR angiography with three-dimensional radial phase contrast.

Authors:  Christopher J François; Darren P Lum; Kevin M Johnson; Benjamin R Landgraf; Thorsten A Bley; Scott B Reeder; Mark L Schiebler; Thomas M Grist; Oliver Wieben
Journal:  Radiology       Date:  2010-10-27       Impact factor: 11.105

4.  Arterial flow characteristics in the presence of vascular disease and implications for fast spin echo-based noncontrast MR angiography.

Authors:  Pippa Storey; Ruth P Lim; Sooah Kim; David R Stoffel; Vivian S Lee
Journal:  J Magn Reson Imaging       Date:  2011-09-29       Impact factor: 4.813

5.  Tailoring the flow sensitivity of fast spin-echo sequences for noncontrast peripheral MR angiography.

Authors:  Pippa Storey; Iliyana P Atanasova; Ruth P Lim; Jian Xu; Daniel Kim; Qun Chen; Vivian S Lee
Journal:  Magn Reson Med       Date:  2010-10       Impact factor: 4.668

6.  Nonenhanced magnetic resonance angiography (MRA) of the calf arteries at 3 Tesla: intraindividual comparison of 3D flow-dependent subtractive MRA and 2D flow-independent non-subtractive MRA.

Authors:  Gesine Knobloch; Marie-Teres Lauff; Sebastian Hirsch; Carsten Schwenke; Bernd Hamm; Moritz Wagner
Journal:  Eur Radiol       Date:  2016-02-10       Impact factor: 5.315

7.  Interactive two-dimensional fresh blood imaging: a feasibility study.

Authors:  Pauline Wong; Martin J Graves; David J Lomas
Journal:  Eur Radiol       Date:  2008-11-04       Impact factor: 5.315

8.  Non-contrast-enhanced MR angiography in critical limb ischemia: performance of quiescent-interval single-shot (QISS) and TSE-based subtraction techniques.

Authors:  Mustafa A Altaha; Jeffrey D Jaskolka; Kongteng Tan; Manuela Rick; Peter Schmitt; Ravi J Menezes; Bernd J Wintersperger
Journal:  Eur Radiol       Date:  2016-06-28       Impact factor: 5.315

9.  Vascular abnormalities correlate with decreased soft tissue volumes in idiopathic clubfoot.

Authors:  Laura J Merrill; Christina A Gurnett; Marilyn Siegel; Sushil Sonavane; Matthew B Dobbs
Journal:  Clin Orthop Relat Res       Date:  2010-11-02       Impact factor: 4.176

10.  Three-dimensional electrocardiographically gated variable flip angle FSE imaging for MR angiography of the hands at 3.0 T: initial experience.

Authors:  Ruth P Lim; Pippa Storey; Iliyana P Atanasova; Jian Xu; Elizabeth M Hecht; James S Babb; David R Stoffel; Hugo Chang; Kellyanne McGorty; Qun Chen; Henry Rusinek; H Michael Belmont; Vivian S Lee
Journal:  Radiology       Date:  2009-06-30       Impact factor: 11.105

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.