Literature DB >> 17622966

Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters.

Olaf Dietrich1, José G Raya, Scott B Reeder, Maximilian F Reiser, Stefan O Schoenberg.   

Abstract

PURPOSE: To evaluate the validity of different approaches to determine the signal-to-noise ratio (SNR) in MRI experiments with multi-element surface coils, parallel imaging, and different reconstruction filters.
MATERIALS AND METHODS: Four different approaches of SNR calculation were compared in phantom measurements and in vivo based on: 1) the pixel-by-pixel standard deviation (SD) in multiple repeated acquisitions; 2) the signal statistics in a difference image; and 3) and 4) the statistics in two separate regions of a single image employing either the mean value or the SD of background noise. Different receiver coil systems (with one and eight channels), acquisitions with and without parallel imaging, and five different reconstruction filters were compared.
RESULTS: Averaged over all phantom measurements, the deviations from the reference value provided by the multiple-acquisitions method are 2.7% (SD 1.6%) for the difference method, 37.7% (25.9%) for the evaluation of the mean value of background noise, and 34.0% (38.1%) for the evaluation of the SD of background noise.
CONCLUSION: The conventionally determined SNR based on separate signal and noise regions in a single image will in general not agree with the true SNR measured in images after the application of certain reconstruction filters, multichannel reconstruction, or parallel imaging. (c) 2007 Wiley-Liss, Inc.

Mesh:

Year:  2007        PMID: 17622966     DOI: 10.1002/jmri.20969

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  268 in total

1.  Magnetic resonance imaging of the knee at 3 and 7 tesla: a comparison using dedicated multi-channel coils and optimised 2D and 3D protocols.

Authors:  Goetz H Welsch; Vladimir Juras; Pavol Szomolanyi; Tallal C Mamisch; Peter Baer; Claudia Kronnerwetter; Matthias Blanke; Hiroyuki Fujita; Siegfried Trattnig
Journal:  Eur Radiol       Date:  2012-04-27       Impact factor: 5.315

2.  In vivo and in vitro validation of aortic flow quantification by time-resolved three-dimensional velocity-encoded MRI.

Authors:  Fabian Rengier; Michael Delles; Roland Unterhinninghofen; Sebastian Ley; Matthias Müller-Eschner; Sasan Partovi; Philipp Geisbüsch; Rüdiger Dillmann; Hans-Ulrich Kauczor; Hendrik von Tengg-Kobligk
Journal:  Int J Cardiovasc Imaging       Date:  2012-02-24       Impact factor: 2.357

3.  Reduced-distortion diffusion MRI of the craniovertebral junction.

Authors:  M Iima; A Yamamoto; V Brion; T Okada; M Kanagaki; K Togashi; D Le Bihan
Journal:  AJNR Am J Neuroradiol       Date:  2012-03-01       Impact factor: 3.825

4.  Measuring signal-to-noise ratio in partially parallel imaging MRI.

Authors:  Frank L Goerner; Geoffrey D Clarke
Journal:  Med Phys       Date:  2011-09       Impact factor: 4.071

5.  Application of a semiautomated contour segmentation tool to identify the intervertebral nucleus pulposus in MR images.

Authors:  B P Bechara; S K Leckie; B W Bowman; C E Davies; B I Woods; E Kanal; G A Sowa; J D Kang
Journal:  AJNR Am J Neuroradiol       Date:  2010-06-25       Impact factor: 3.825

6.  Assessment of Silent T1-weighted head imaging at 7 T.

Authors:  Mauro Costagli; Mark R Symms; Lorenzo Angeli; Douglas A C Kelley; Laura Biagi; Andrea Farnetani; Catarina Rua; Graziella Donatelli; Gianluigi Tiberi; Michela Tosetti; Mirco Cosottini
Journal:  Eur Radiol       Date:  2015-08-29       Impact factor: 5.315

7.  Effect of imaging parameters on the accuracy of apparent diffusion coefficient and optimization strategies.

Authors:  Azim Celik
Journal:  Diagn Interv Radiol       Date:  2016 Jan-Feb       Impact factor: 2.630

8.  Acoustic noise reduction in T 1- and proton-density-weighted turbo spin-echo imaging.

Authors:  Martin Ott; Martin Blaimer; Felix Breuer; David Grodzki; Björn Heismann; Peter Jakob
Journal:  MAGMA       Date:  2015-10-22       Impact factor: 2.310

9.  Diffusion MRI noise mapping using random matrix theory.

Authors:  Jelle Veraart; Els Fieremans; Dmitry S Novikov
Journal:  Magn Reson Med       Date:  2015-11-24       Impact factor: 4.668

10.  Simultaneous magnetic resonance angiography and perfusion (MRAP) measurement: initial application in lower extremity skeletal muscle.

Authors:  Katherine L Wright; Nicole Seiberlich; John A Jesberger; Dean A Nakamoto; Raymond F Muzic; Mark A Griswold; Vikas Gulani
Journal:  J Magn Reson Imaging       Date:  2013-02-06       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.